Fx Copy
LaTeX Copy
The Treatability Constant at 30°C and 20ft depth refers to a rate coefficient indicating the effectiveness of a treatment process at the standard temperature of 30°C at 20ft filter depth. Check FAQs
K30/20=K30/25(D2D1)a
K30/20 - Treatability Constant at 30°C and 20ft Depth?K30/25 - Treatability Constant at 30°C and 25ft Depth?D2 - Depth of Actual Filter?D1 - Depth of Reference Filter?a - Empirical Constant?

Treatability Constant at 30 degree Celsius and 20 ft Filter Depth Example

With values
With units
Only example

Here is how the Treatability Constant at 30 degree Celsius and 20 ft Filter Depth equation looks like with Values.

Here is how the Treatability Constant at 30 degree Celsius and 20 ft Filter Depth equation looks like with Units.

Here is how the Treatability Constant at 30 degree Celsius and 20 ft Filter Depth equation looks like.

28.6273Edit=26.8Edit(7.6Edit6.1Edit)0.3Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Treatability Constant at 30 degree Celsius and 20 ft Filter Depth

Treatability Constant at 30 degree Celsius and 20 ft Filter Depth Solution

Follow our step by step solution on how to calculate Treatability Constant at 30 degree Celsius and 20 ft Filter Depth?

FIRST Step Consider the formula
K30/20=K30/25(D2D1)a
Next Step Substitute values of Variables
K30/20=26.8(7.6m6.1m)0.3
Next Step Prepare to Evaluate
K30/20=26.8(7.66.1)0.3
Next Step Evaluate
K30/20=28.6272691500693
LAST Step Rounding Answer
K30/20=28.6273

Treatability Constant at 30 degree Celsius and 20 ft Filter Depth Formula Elements

Variables
Treatability Constant at 30°C and 20ft Depth
The Treatability Constant at 30°C and 20ft depth refers to a rate coefficient indicating the effectiveness of a treatment process at the standard temperature of 30°C at 20ft filter depth.
Symbol: K30/20
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Treatability Constant at 30°C and 25ft Depth
The Treatability Constant at 30°C and 25ft depth refers to a rate coefficient indicating the effectiveness of a treatment process at the standard temperature of 30°C at 25ft filter depth.
Symbol: K30/25
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Depth of Actual Filter
The Depth of Actual Filter refers to the vertical distance from the top surface to the bottom of the filter media, impacting filtration efficiency, typically measured in meters (m).
Symbol: D2
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Depth of Reference Filter
The Depth of Reference Filter refers to the standard vertical distance used to compare filtration systems, typically measured in meters (m), to assess relative performance.
Symbol: D1
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Empirical Constant
The Empirical Constant refers to a value derived from experimental data and observations, used in equations to predict or describe phenomena within specific conditions.
Symbol: a
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.

Other Formulas to find Treatability Constant at 30°C and 20ft Depth

​Go Treatability Constant at 30 degrees Celsius and 20 ft Filter Depth
K30/20=K20/20(θ)T-20

Other formulas in Treatability Constant category

​Go Treatability Constant at 20 Degrees Celsius and 20 ft Filter Depth
K20/20=K30/20(θ)T-20
​Go Temperature Activity Coefficient given Treatability Constant
θ=(K30/20K20/20)1T-20
​Go Wastewater Temperature using Treatability Constant
T=20+(ln(K30/20K20/20)(1ln(θ)))
​Go Treatability Constant at 30 degree Celsius and 25 ft Filter Depth
K30/25=K30/20(D1D2)a

How to Evaluate Treatability Constant at 30 degree Celsius and 20 ft Filter Depth?

Treatability Constant at 30 degree Celsius and 20 ft Filter Depth evaluator uses Treatability Constant at 30°C and 20ft Depth = Treatability Constant at 30°C and 25ft Depth*(Depth of Actual Filter/Depth of Reference Filter)^(Empirical Constant) to evaluate the Treatability Constant at 30°C and 20ft Depth, The Treatability Constant at 30 degree Celsius and 20 ft Filter Depth formula is defined as the rate coefficient indicating the effectiveness of a treatment process at the standard temperature of 30°C at 20ft filter depth, reference filter and empirical constant. Treatability Constant at 30°C and 20ft Depth is denoted by K30/20 symbol.

How to evaluate Treatability Constant at 30 degree Celsius and 20 ft Filter Depth using this online evaluator? To use this online evaluator for Treatability Constant at 30 degree Celsius and 20 ft Filter Depth, enter Treatability Constant at 30°C and 25ft Depth (K30/25), Depth of Actual Filter (D2), Depth of Reference Filter (D1) & Empirical Constant (a) and hit the calculate button.

FAQs on Treatability Constant at 30 degree Celsius and 20 ft Filter Depth

What is the formula to find Treatability Constant at 30 degree Celsius and 20 ft Filter Depth?
The formula of Treatability Constant at 30 degree Celsius and 20 ft Filter Depth is expressed as Treatability Constant at 30°C and 20ft Depth = Treatability Constant at 30°C and 25ft Depth*(Depth of Actual Filter/Depth of Reference Filter)^(Empirical Constant). Here is an example- 30.24481 = 26.8*(7.6/6.1)^(0.3).
How to calculate Treatability Constant at 30 degree Celsius and 20 ft Filter Depth?
With Treatability Constant at 30°C and 25ft Depth (K30/25), Depth of Actual Filter (D2), Depth of Reference Filter (D1) & Empirical Constant (a) we can find Treatability Constant at 30 degree Celsius and 20 ft Filter Depth using the formula - Treatability Constant at 30°C and 20ft Depth = Treatability Constant at 30°C and 25ft Depth*(Depth of Actual Filter/Depth of Reference Filter)^(Empirical Constant).
What are the other ways to Calculate Treatability Constant at 30°C and 20ft Depth?
Here are the different ways to Calculate Treatability Constant at 30°C and 20ft Depth-
  • Treatability Constant at 30°C and 20ft Depth=Treatability Constant at 20°C and 20ft Depth*(Temperature Activity Coefficient)^(Wastewater Temperature-20)OpenImg
Copied!