Treatability Constant at 20 Degrees Celsius and 20 ft Filter Depth Formula

Fx Copy
LaTeX Copy
The Treatability Constant at 20°C and 20ft Depth refers to a rate coefficient indicating the effectiveness of a treatment process at the standard temperature of 20°C at 20ft filter depth. Check FAQs
K20/20=K30/20(θ)T-20
K20/20 - Treatability Constant at 20°C and 20ft Depth?K30/20 - Treatability Constant at 30°C and 20ft Depth?θ - Temperature Activity Coefficient?T - Wastewater Temperature?

Treatability Constant at 20 Degrees Celsius and 20 ft Filter Depth Example

With values
With units
Only example

Here is how the Treatability Constant at 20 Degrees Celsius and 20 ft Filter Depth equation looks like with Values.

Here is how the Treatability Constant at 20 Degrees Celsius and 20 ft Filter Depth equation looks like with Units.

Here is how the Treatability Constant at 20 Degrees Celsius and 20 ft Filter Depth equation looks like.

0.002Edit=28.62Edit(1.035Edit)25Edit-20
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Treatability Constant at 20 Degrees Celsius and 20 ft Filter Depth

Treatability Constant at 20 Degrees Celsius and 20 ft Filter Depth Solution

Follow our step by step solution on how to calculate Treatability Constant at 20 Degrees Celsius and 20 ft Filter Depth?

FIRST Step Consider the formula
K20/20=K30/20(θ)T-20
Next Step Substitute values of Variables
K20/20=28.62(1.035)25°C-20
Next Step Convert Units
K20/20=28.62(1.035)298.15K-20
Next Step Prepare to Evaluate
K20/20=28.62(1.035)298.15-20
Next Step Evaluate
K20/20=0.00199991406409532
LAST Step Rounding Answer
K20/20=0.002

Treatability Constant at 20 Degrees Celsius and 20 ft Filter Depth Formula Elements

Variables
Treatability Constant at 20°C and 20ft Depth
The Treatability Constant at 20°C and 20ft Depth refers to a rate coefficient indicating the effectiveness of a treatment process at the standard temperature of 20°C at 20ft filter depth.
Symbol: K20/20
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Treatability Constant at 30°C and 20ft Depth
The Treatability Constant at 30°C and 20ft depth refers to a rate coefficient indicating the effectiveness of a treatment process at the standard temperature of 30°C at 20ft filter depth.
Symbol: K30/20
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Temperature Activity Coefficient
The Temperature Activity Coefficient refers to a factor that adjusts reaction rates or biological activity in response to temperature changes, commonly used in biochemical processes.
Symbol: θ
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Wastewater Temperature
The Wastewater Temperature refers to the measure of heat present in wastewater, affecting treatment efficiency and biological activity, typically measured in degrees Celsius (°C).
Symbol: T
Measurement: TemperatureUnit: °C
Note: Value should be greater than 0.

Other formulas in Treatability Constant category

​Go Treatability Constant at 30 degrees Celsius and 20 ft Filter Depth
K30/20=K20/20(θ)T-20
​Go Temperature Activity Coefficient given Treatability Constant
θ=(K30/20K20/20)1T-20
​Go Wastewater Temperature using Treatability Constant
T=20+(ln(K30/20K20/20)(1ln(θ)))
​Go Treatability Constant at 30 degree Celsius and 25 ft Filter Depth
K30/25=K30/20(D1D2)a

How to Evaluate Treatability Constant at 20 Degrees Celsius and 20 ft Filter Depth?

Treatability Constant at 20 Degrees Celsius and 20 ft Filter Depth evaluator uses Treatability Constant at 20°C and 20ft Depth = Treatability Constant at 30°C and 20ft Depth/(Temperature Activity Coefficient)^(Wastewater Temperature-20) to evaluate the Treatability Constant at 20°C and 20ft Depth, The Treatability Constant at 20 degrees Celsius and 20 ft Filter Depth is defined as a rate coefficient indicating the effectiveness of a treatment process at the standard temperature of 20°C at 20ft filter depth. Treatability Constant at 20°C and 20ft Depth is denoted by K20/20 symbol.

How to evaluate Treatability Constant at 20 Degrees Celsius and 20 ft Filter Depth using this online evaluator? To use this online evaluator for Treatability Constant at 20 Degrees Celsius and 20 ft Filter Depth, enter Treatability Constant at 30°C and 20ft Depth (K30/20), Temperature Activity Coefficient (θ) & Wastewater Temperature (T) and hit the calculate button.

FAQs on Treatability Constant at 20 Degrees Celsius and 20 ft Filter Depth

What is the formula to find Treatability Constant at 20 Degrees Celsius and 20 ft Filter Depth?
The formula of Treatability Constant at 20 Degrees Celsius and 20 ft Filter Depth is expressed as Treatability Constant at 20°C and 20ft Depth = Treatability Constant at 30°C and 20ft Depth/(Temperature Activity Coefficient)^(Wastewater Temperature-20). Here is an example- 0.00014 = treatability_constant_at_30_20/(1.035)^(298.15-20).
How to calculate Treatability Constant at 20 Degrees Celsius and 20 ft Filter Depth?
With Treatability Constant at 30°C and 20ft Depth (K30/20), Temperature Activity Coefficient (θ) & Wastewater Temperature (T) we can find Treatability Constant at 20 Degrees Celsius and 20 ft Filter Depth using the formula - Treatability Constant at 20°C and 20ft Depth = Treatability Constant at 30°C and 20ft Depth/(Temperature Activity Coefficient)^(Wastewater Temperature-20).
Copied!