Power Transmitted is the amount of power that is transferred from its place of generation to a location where it is applied to perform useful work. Check FAQs
P=PlossA(Vmcos(Φ))2(2+2)ρL
P - Power Transmitted?Ploss - Line Losses?A - Area of Underground AC Wire?Vm - Maximum Voltage Underground AC?Φ - Phase Difference?ρ - Resistivity?L - Length of Underground AC Wire?

Transmitted Power using Line Losses (2-Phase 3-Wire US) Example

With values
With units
Only example

Here is how the Transmitted Power using Line Losses (2-Phase 3-Wire US) equation looks like with Values.

Here is how the Transmitted Power using Line Losses (2-Phase 3-Wire US) equation looks like with Units.

Here is how the Transmitted Power using Line Losses (2-Phase 3-Wire US) equation looks like.

9866.0579Edit=2.67Edit1.28Edit(230Editcos(30Edit))2(2+2)1.7E-5Edit24Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Transmitted Power using Line Losses (2-Phase 3-Wire US)

Transmitted Power using Line Losses (2-Phase 3-Wire US) Solution

Follow our step by step solution on how to calculate Transmitted Power using Line Losses (2-Phase 3-Wire US)?

FIRST Step Consider the formula
P=PlossA(Vmcos(Φ))2(2+2)ρL
Next Step Substitute values of Variables
P=2.67W1.28(230Vcos(30°))2(2+2)1.7E-5Ω*m24m
Next Step Convert Units
P=2.67W1.28(230Vcos(0.5236rad))2(2+2)1.7E-5Ω*m24m
Next Step Prepare to Evaluate
P=2.671.28(230cos(0.5236))2(2+2)1.7E-524
Next Step Evaluate
P=9866.05790575397W
LAST Step Rounding Answer
P=9866.0579W

Transmitted Power using Line Losses (2-Phase 3-Wire US) Formula Elements

Variables
Functions
Power Transmitted
Power Transmitted is the amount of power that is transferred from its place of generation to a location where it is applied to perform useful work.
Symbol: P
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Line Losses
Line Losses is defined as the total losses occurring in an Underground AC line when in use.
Symbol: Ploss
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Area of Underground AC Wire
Area of Underground AC Wire is defined as the cross-sectional area of the wire of an AC supply system.
Symbol: A
Measurement: AreaUnit:
Note: Value can be positive or negative.
Maximum Voltage Underground AC
Maximum Voltage Underground AC is defined as the peak amplitude of the AC voltage supplied to the line or wire.
Symbol: Vm
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Phase Difference
Phase Difference is defined as the difference between the phasor of apparent and real power (in degrees) or between voltage and current in an ac circuit.
Symbol: Φ
Measurement: AngleUnit: °
Note: Value should be greater than 0.
Resistivity
Resistivity is the measure of how strongly a material opposes the flow of current through them.
Symbol: ρ
Measurement: Electric ResistivityUnit: Ω*m
Note: Value can be positive or negative.
Length of Underground AC Wire
Length of Underground AC Wire is the total length of the wire from one end to other end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.
cos
Cosine of an angle is the ratio of the side adjacent to the angle to the hypotenuse of the triangle.
Syntax: cos(Angle)
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other Formulas to find Power Transmitted

​Go Power Transmitted using Volume of Conductor Material (2 Phase 3 Wire US)
P=PlossV(Vmcos(Φ))2ρ(((2+2)L)2)
​Go Power Transmitted using Current in Each Outer (2-Phase 3-Wire US)
P=IVmcos(Φ)

Other formulas in Power and Power Factor category

​Go Power Factor using Volume of Conductor Material (2 Phase 3 Wire US)
PF=(2.194)KV
​Go Power Factor using Line Losses (2-Phase 3-Wire US)
PF=(PVm)(2+2)ρLPlossA

How to Evaluate Transmitted Power using Line Losses (2-Phase 3-Wire US)?

Transmitted Power using Line Losses (2-Phase 3-Wire US) evaluator uses Power Transmitted = sqrt(Line Losses*Area of Underground AC Wire*(Maximum Voltage Underground AC*cos(Phase Difference))^2/((2+sqrt(2))*Resistivity*Length of Underground AC Wire)) to evaluate the Power Transmitted, The Transmitted Power using Line Losses (2-Phase 3-Wire US) formula is defined as the bulk movement of electrical energy from a generating site, such as a power station or power plant, to an electrical substation where voltage is transformed and distributed to consumers or other substations. Power Transmitted is denoted by P symbol.

How to evaluate Transmitted Power using Line Losses (2-Phase 3-Wire US) using this online evaluator? To use this online evaluator for Transmitted Power using Line Losses (2-Phase 3-Wire US), enter Line Losses (Ploss), Area of Underground AC Wire (A), Maximum Voltage Underground AC (Vm), Phase Difference (Φ), Resistivity (ρ) & Length of Underground AC Wire (L) and hit the calculate button.

FAQs on Transmitted Power using Line Losses (2-Phase 3-Wire US)

What is the formula to find Transmitted Power using Line Losses (2-Phase 3-Wire US)?
The formula of Transmitted Power using Line Losses (2-Phase 3-Wire US) is expressed as Power Transmitted = sqrt(Line Losses*Area of Underground AC Wire*(Maximum Voltage Underground AC*cos(Phase Difference))^2/((2+sqrt(2))*Resistivity*Length of Underground AC Wire)). Here is an example- 9866.058 = sqrt(2.67*1.28*(230*cos(0.5235987755982))^2/((2+sqrt(2))*1.7E-05*24)).
How to calculate Transmitted Power using Line Losses (2-Phase 3-Wire US)?
With Line Losses (Ploss), Area of Underground AC Wire (A), Maximum Voltage Underground AC (Vm), Phase Difference (Φ), Resistivity (ρ) & Length of Underground AC Wire (L) we can find Transmitted Power using Line Losses (2-Phase 3-Wire US) using the formula - Power Transmitted = sqrt(Line Losses*Area of Underground AC Wire*(Maximum Voltage Underground AC*cos(Phase Difference))^2/((2+sqrt(2))*Resistivity*Length of Underground AC Wire)). This formula also uses Cosine, Square Root Function function(s).
What are the other ways to Calculate Power Transmitted?
Here are the different ways to Calculate Power Transmitted-
  • Power Transmitted=sqrt(Line Losses*Volume Of Conductor*(Maximum Voltage Underground AC*cos(Phase Difference))^2/(Resistivity*(((2+sqrt(2))*Length of Underground AC Wire)^2)))OpenImg
  • Power Transmitted=Current Underground AC*Maximum Voltage Underground AC*cos(Phase Difference)OpenImg
  • Power Transmitted=(Current Underground AC*Maximum Voltage Underground AC*cos(Phase Difference))/sqrt(2)OpenImg
Can the Transmitted Power using Line Losses (2-Phase 3-Wire US) be negative?
Yes, the Transmitted Power using Line Losses (2-Phase 3-Wire US), measured in Power can be negative.
Which unit is used to measure Transmitted Power using Line Losses (2-Phase 3-Wire US)?
Transmitted Power using Line Losses (2-Phase 3-Wire US) is usually measured using the Watt[W] for Power. Kilowatt[W], Milliwatt[W], Microwatt[W] are the few other units in which Transmitted Power using Line Losses (2-Phase 3-Wire US) can be measured.