Fx Copy
LaTeX Copy
Transmissivity is the rate at which groundwater flows horizontally through an aquifer or the degree to which a medium allows something, in particular electromagnetic radiation, to pass through it. Check FAQs
T=70qΔs
T - Transmissivity?q - Pumping Rate?Δs - Drawdown Across One Log Cycle?

Transmissivity for Inconsistent Units from Distance Drawdown Graphs Example

With values
With units
Only example

Here is how the Transmissivity for Inconsistent Units from Distance Drawdown Graphs equation looks like with Values.

Here is how the Transmissivity for Inconsistent Units from Distance Drawdown Graphs equation looks like with Units.

Here is how the Transmissivity for Inconsistent Units from Distance Drawdown Graphs equation looks like.

10.9989Edit=707Edit44.55Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Engineering Hydrology » fx Transmissivity for Inconsistent Units from Distance Drawdown Graphs

Transmissivity for Inconsistent Units from Distance Drawdown Graphs Solution

Follow our step by step solution on how to calculate Transmissivity for Inconsistent Units from Distance Drawdown Graphs?

FIRST Step Consider the formula
T=70qΔs
Next Step Substitute values of Variables
T=707m³/s44.55
Next Step Prepare to Evaluate
T=70744.55
Next Step Evaluate
T=10.9988776655443m²/s
LAST Step Rounding Answer
T=10.9989m²/s

Transmissivity for Inconsistent Units from Distance Drawdown Graphs Formula Elements

Variables
Transmissivity
Transmissivity is the rate at which groundwater flows horizontally through an aquifer or the degree to which a medium allows something, in particular electromagnetic radiation, to pass through it.
Symbol: T
Measurement: Kinematic ViscosityUnit: m²/s
Note: Value can be positive or negative.
Pumping Rate
The Pumping Rate is referred as volume of water (or other fluid) that is pumped per unit of time. It’s typically measured in units like liters per second (L/s) or cubic meters per hour (m³/h).
Symbol: q
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value can be positive or negative.
Drawdown Across One Log Cycle
The Drawdown Across One Log Cycle is referred as change in water level (or hydraulic head) in an aquifer due to pumping from a well.
Symbol: Δs
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.

Other Formulas to find Transmissivity

​Go Transmissivity from Distance Drawdown Graphs
T=2.3q2πΔsD
​Go Transmissivity given Storage Coefficient from Distance Drawdown
T=Sro22.25st

Other formulas in Distance Drawdown Analysis category

​Go Storage Coefficient from Distance-Drawdown Graphs
S=2.25Tstro2
​Go Pumping Rate from Distance Drawdown Graphs
q=T2πΔsD2.3
​Go Drawdown across One Log Cycle from Distance Drawdown Graphs given Transmissivity
ΔsD=2.3qT2π
​Go Time at which Drawdowns are measured for Storage Coefficient
st=Sro22.25T

How to Evaluate Transmissivity for Inconsistent Units from Distance Drawdown Graphs?

Transmissivity for Inconsistent Units from Distance Drawdown Graphs evaluator uses Transmissivity = 70*Pumping Rate/Drawdown Across One Log Cycle to evaluate the Transmissivity, The Transmissivity for Inconsistent Units from Distance Drawdown Graphs formula is defined as the rate at which groundwater flows horizontally through an aquifer. Transmittance, the effectiveness of transmitting radiant energy though a volume. Transmissivity is denoted by T symbol.

How to evaluate Transmissivity for Inconsistent Units from Distance Drawdown Graphs using this online evaluator? To use this online evaluator for Transmissivity for Inconsistent Units from Distance Drawdown Graphs, enter Pumping Rate (q) & Drawdown Across One Log Cycle (Δs) and hit the calculate button.

FAQs on Transmissivity for Inconsistent Units from Distance Drawdown Graphs

What is the formula to find Transmissivity for Inconsistent Units from Distance Drawdown Graphs?
The formula of Transmissivity for Inconsistent Units from Distance Drawdown Graphs is expressed as Transmissivity = 70*Pumping Rate/Drawdown Across One Log Cycle. Here is an example- 10.99888 = 70*7/44.55.
How to calculate Transmissivity for Inconsistent Units from Distance Drawdown Graphs?
With Pumping Rate (q) & Drawdown Across One Log Cycle (Δs) we can find Transmissivity for Inconsistent Units from Distance Drawdown Graphs using the formula - Transmissivity = 70*Pumping Rate/Drawdown Across One Log Cycle.
What are the other ways to Calculate Transmissivity?
Here are the different ways to Calculate Transmissivity-
  • Transmissivity=2.3*Pumping Rate/(2*pi*Drawdown Across Log Cycle)OpenImg
  • Transmissivity=(Storage Coefficient*Distance from Pumping Well to Point Intersection^2)/(2.25*Total Drawdown)OpenImg
Can the Transmissivity for Inconsistent Units from Distance Drawdown Graphs be negative?
Yes, the Transmissivity for Inconsistent Units from Distance Drawdown Graphs, measured in Kinematic Viscosity can be negative.
Which unit is used to measure Transmissivity for Inconsistent Units from Distance Drawdown Graphs?
Transmissivity for Inconsistent Units from Distance Drawdown Graphs is usually measured using the Square Meter per Second[m²/s] for Kinematic Viscosity. Square Meter per Hour[m²/s], Square Centimeter per Second[m²/s], Square Millimeter per Second[m²/s] are the few other units in which Transmissivity for Inconsistent Units from Distance Drawdown Graphs can be measured.
Copied!