Source Parasitic Capacitance is an unavoidable and usually unwanted capacitance. Check FAQs
Csop=(CjbsAs)+(CbswPs)
Csop - Source Parasitic Capacitance?Cjbs - Capacitance between Junction of Body and Source?As - Area of Source Diffusion?Cbsw - Capacitance between Junction of Body and Side wall?Ps - Sidewall Perimeter of Source Diffusion?

Total Source Parasitic Capacitance Example

With values
With units
Only example

Here is how the Total Source Parasitic Capacitance equation looks like with Values.

Here is how the Total Source Parasitic Capacitance equation looks like with Units.

Here is how the Total Source Parasitic Capacitance equation looks like.

0.419Edit=(76.46Edit5479Edit)+(0.1391Edit301.64Edit)
You are here -
HomeIcon Home » Category Engineering » Category Electronics » Category VLSI Fabrication » fx Total Source Parasitic Capacitance

Total Source Parasitic Capacitance Solution

Follow our step by step solution on how to calculate Total Source Parasitic Capacitance?

FIRST Step Consider the formula
Csop=(CjbsAs)+(CbswPs)
Next Step Substitute values of Variables
Csop=(76.46μF/mm²5479mm²)+(0.1391μF/mm301.64mm)
Next Step Convert Units
Csop=(76.46F/m²0.0055)+(0.0001F/m0.3016m)
Next Step Prepare to Evaluate
Csop=(76.460.0055)+(0.00010.3016)
Next Step Evaluate
Csop=0.418966298124F/m²
Next Step Convert to Output's Unit
Csop=0.418966298124μF/mm²
LAST Step Rounding Answer
Csop=0.419μF/mm²

Total Source Parasitic Capacitance Formula Elements

Variables
Source Parasitic Capacitance
Source Parasitic Capacitance is an unavoidable and usually unwanted capacitance.
Symbol: Csop
Measurement: Oxide Capacitance Per Unit AreaUnit: μF/mm²
Note: Value should be greater than 0.
Capacitance between Junction of Body and Source
Capacitance between Junction of Body and Source is defined as the capacitance between the junction of the body and the source junction of MOSFET.
Symbol: Cjbs
Measurement: Oxide Capacitance Per Unit AreaUnit: μF/mm²
Note: Value should be greater than 0.
Area of Source Diffusion
Area of Source Diffusion is defined as net movement of anything from a region of higher concentration to a region of lower concentration area in the source gate.
Symbol: As
Measurement: AreaUnit: mm²
Note: Value should be greater than 0.
Capacitance between Junction of Body and Side wall
Capacitance between Junction of Body and Side wall is a parasitic capacitance that can affect circuit performance.
Symbol: Cbsw
Measurement: PermittivityUnit: μF/mm
Note: Value should be greater than 0.
Sidewall Perimeter of Source Diffusion
Sidewall Perimeter of Source Diffusion is defined as perimeter of source diffusion not including edge under gate.
Symbol: Ps
Measurement: LengthUnit: mm
Note: Value should be greater than 0.

Other formulas in VLSI Material Optimization category

​Go Body Effect Coefficient
γ=modu̲s(Vt-Vt0Φs+(Vsb)-Φs)
​Go Channel Charge
Qch=Cg(Vgc-Vt)
​Go Critical Voltage
Vx=ExEch
​Go DIBL Coefficient
η=Vt0-VtVds

How to Evaluate Total Source Parasitic Capacitance?

Total Source Parasitic Capacitance evaluator uses Source Parasitic Capacitance = (Capacitance between Junction of Body and Source*Area of Source Diffusion)+(Capacitance between Junction of Body and Side wall*Sidewall Perimeter of Source Diffusion) to evaluate the Source Parasitic Capacitance, The Total Source Parasitic Capacitance formula is defined as an unavoidable and usually unwanted capacitance that exists between the parts of an electronic component or circuit simply because of their proximity to each other. Source Parasitic Capacitance is denoted by Csop symbol.

How to evaluate Total Source Parasitic Capacitance using this online evaluator? To use this online evaluator for Total Source Parasitic Capacitance, enter Capacitance between Junction of Body and Source (Cjbs), Area of Source Diffusion (As), Capacitance between Junction of Body and Side wall (Cbsw) & Sidewall Perimeter of Source Diffusion (Ps) and hit the calculate button.

FAQs on Total Source Parasitic Capacitance

What is the formula to find Total Source Parasitic Capacitance?
The formula of Total Source Parasitic Capacitance is expressed as Source Parasitic Capacitance = (Capacitance between Junction of Body and Source*Area of Source Diffusion)+(Capacitance between Junction of Body and Side wall*Sidewall Perimeter of Source Diffusion). Here is an example- 0.418966 = (76.46*0.005479)+(0.0001391*0.30164).
How to calculate Total Source Parasitic Capacitance?
With Capacitance between Junction of Body and Source (Cjbs), Area of Source Diffusion (As), Capacitance between Junction of Body and Side wall (Cbsw) & Sidewall Perimeter of Source Diffusion (Ps) we can find Total Source Parasitic Capacitance using the formula - Source Parasitic Capacitance = (Capacitance between Junction of Body and Source*Area of Source Diffusion)+(Capacitance between Junction of Body and Side wall*Sidewall Perimeter of Source Diffusion).
Can the Total Source Parasitic Capacitance be negative?
No, the Total Source Parasitic Capacitance, measured in Oxide Capacitance Per Unit Area cannot be negative.
Which unit is used to measure Total Source Parasitic Capacitance?
Total Source Parasitic Capacitance is usually measured using the Microfarad per Square Millimeter[μF/mm²] for Oxide Capacitance Per Unit Area. Farad per Square Meter[μF/mm²], Nanofarad per Square Centimeter[μF/mm²], Microfarad per Square Centimeter[μF/mm²] are the few other units in which Total Source Parasitic Capacitance can be measured.
Copied!