Total Resistance of Coaxial Cable Formula

Fx Copy
LaTeX Copy
Total Resistance of Coaxial Cable is a measure of the opposition that the conductor of the coaxial cable presents to the flow of electric current. Check FAQs
Rt=12πδσc(1ar+1br)
Rt - Total Resistance of Coaxial Cable?δ - Skin Depth?σc - Electrical Conductivity?ar - Inner Radius of Coaxial Cable?br - Outer Radius of Coaxial Cable?π - Archimedes' constant?

Total Resistance of Coaxial Cable Example

With values
With units
Only example

Here is how the Total Resistance of Coaxial Cable equation looks like with Values.

Here is how the Total Resistance of Coaxial Cable equation looks like with Units.

Here is how the Total Resistance of Coaxial Cable equation looks like.

8.0228Edit=123.141620.1Edit0.4Edit(10.25Edit+118.91Edit)
You are here -
HomeIcon Home » Category Engineering » Category Electronics » Category Electromagnetic Field Theory » fx Total Resistance of Coaxial Cable

Total Resistance of Coaxial Cable Solution

Follow our step by step solution on how to calculate Total Resistance of Coaxial Cable?

FIRST Step Consider the formula
Rt=12πδσc(1ar+1br)
Next Step Substitute values of Variables
Rt=12π20.1cm0.4S/cm(10.25cm+118.91cm)
Next Step Substitute values of Constants
Rt=123.141620.1cm0.4S/cm(10.25cm+118.91cm)
Next Step Convert Units
Rt=123.14160.201m40S/m(10.0025m+10.1891m)
Next Step Prepare to Evaluate
Rt=123.14160.20140(10.0025+10.1891)
Next Step Evaluate
Rt=8.02283850351814Ω
LAST Step Rounding Answer
Rt=8.0228Ω

Total Resistance of Coaxial Cable Formula Elements

Variables
Constants
Total Resistance of Coaxial Cable
Total Resistance of Coaxial Cable is a measure of the opposition that the conductor of the coaxial cable presents to the flow of electric current.
Symbol: Rt
Measurement: Electric ResistanceUnit: Ω
Note: Value should be greater than 0.
Skin Depth
Skin depth is a measure of how deeply a current penetrates into a conductor.
Symbol: δ
Measurement: LengthUnit: cm
Note: Value should be greater than 0.
Electrical Conductivity
Electrical Conductivity is a measure of a material's ability to conduct electric current. It is the reciprocal of electrical resistivity.
Symbol: σc
Measurement: Electric ConductivityUnit: S/cm
Note: Value should be greater than 0.
Inner Radius of Coaxial Cable
Inner Radius of Coaxial Cable is the distance from the center to the inner edge of the coaxial cable.
Symbol: ar
Measurement: LengthUnit: cm
Note: Value should be greater than 0.
Outer Radius of Coaxial Cable
Outer Radius of Coaxial Cable is the distance from the center to the outer edge of the coaxial cable.
Symbol: br
Measurement: LengthUnit: cm
Note: Value should be greater than 0.
Archimedes' constant
Archimedes' constant is a mathematical constant that represents the ratio of the circumference of a circle to its diameter.
Symbol: π
Value: 3.14159265358979323846264338327950288

Other formulas in Electrowave Dynamics category

​Go Inductance between Conductors
L=μπ10-7pdpb
​Go Skin Effect Resistivity
Rs=2σcδpb
​Go Characteristic Impedance of Line
Zo=μπ10-7∈'(pdpb)
​Go Conductance of Coaxial Cable
Gc=2πσcln(brar)

How to Evaluate Total Resistance of Coaxial Cable?

Total Resistance of Coaxial Cable evaluator uses Total Resistance of Coaxial Cable = 1/(2*pi*Skin Depth*Electrical Conductivity)*(1/Inner Radius of Coaxial Cable+1/Outer Radius of Coaxial Cable) to evaluate the Total Resistance of Coaxial Cable, Total Resistance of Coaxial Cable formula is used in electrical engineering to assess the impact of the coaxial cable's inner and outer dimensions and the conductivity of the inner and outer conductor on its internal resistance. Total Resistance of Coaxial Cable is denoted by Rt symbol.

How to evaluate Total Resistance of Coaxial Cable using this online evaluator? To use this online evaluator for Total Resistance of Coaxial Cable, enter Skin Depth (δ), Electrical Conductivity c), Inner Radius of Coaxial Cable (ar) & Outer Radius of Coaxial Cable (br) and hit the calculate button.

FAQs on Total Resistance of Coaxial Cable

What is the formula to find Total Resistance of Coaxial Cable?
The formula of Total Resistance of Coaxial Cable is expressed as Total Resistance of Coaxial Cable = 1/(2*pi*Skin Depth*Electrical Conductivity)*(1/Inner Radius of Coaxial Cable+1/Outer Radius of Coaxial Cable). Here is an example- 8.022839 = 1/(2*pi*0.201*40)*(1/0.0025+1/0.1891).
How to calculate Total Resistance of Coaxial Cable?
With Skin Depth (δ), Electrical Conductivity c), Inner Radius of Coaxial Cable (ar) & Outer Radius of Coaxial Cable (br) we can find Total Resistance of Coaxial Cable using the formula - Total Resistance of Coaxial Cable = 1/(2*pi*Skin Depth*Electrical Conductivity)*(1/Inner Radius of Coaxial Cable+1/Outer Radius of Coaxial Cable). This formula also uses Archimedes' constant .
Can the Total Resistance of Coaxial Cable be negative?
No, the Total Resistance of Coaxial Cable, measured in Electric Resistance cannot be negative.
Which unit is used to measure Total Resistance of Coaxial Cable?
Total Resistance of Coaxial Cable is usually measured using the Ohm[Ω] for Electric Resistance. Megohm[Ω], Microhm[Ω], Volt per Ampere[Ω] are the few other units in which Total Resistance of Coaxial Cable can be measured.
Copied!