Fx Copy
LaTeX Copy
The Residue flowrate from Distillation Column is the amount of moles of bottom liquid product (Residue) flowing out from the column per unit time. Check FAQs
W=F-D
W - Residue Flowrate from Distillation Column?F - Feed Flowrate to Distillation Column?D - Distillate Flowrate?

Total Residue Flowrate of Distillation Column from Overall Material Balance Example

With values
With units
Only example

Here is how the Total Residue Flowrate of Distillation Column from Overall Material Balance equation looks like with Values.

Here is how the Total Residue Flowrate of Distillation Column from Overall Material Balance equation looks like with Units.

Here is how the Total Residue Flowrate of Distillation Column from Overall Material Balance equation looks like.

5.8Edit=10Edit-4.2Edit
You are here -
HomeIcon Home » Category Engineering » Category Chemical Engineering » Category Mass Transfer Operations » fx Total Residue Flowrate of Distillation Column from Overall Material Balance

Total Residue Flowrate of Distillation Column from Overall Material Balance Solution

Follow our step by step solution on how to calculate Total Residue Flowrate of Distillation Column from Overall Material Balance?

FIRST Step Consider the formula
W=F-D
Next Step Substitute values of Variables
W=10mol/s-4.2mol/s
Next Step Prepare to Evaluate
W=10-4.2
LAST Step Evaluate
W=5.8mol/s

Total Residue Flowrate of Distillation Column from Overall Material Balance Formula Elements

Variables
Residue Flowrate from Distillation Column
The Residue flowrate from Distillation Column is the amount of moles of bottom liquid product (Residue) flowing out from the column per unit time.
Symbol: W
Measurement: Molar Flow RateUnit: mol/s
Note: Value should be greater than 0.
Feed Flowrate to Distillation Column
The Feed flowrate to Distillation Column is the amount of moles of feed flowing in the column per unit time.
Symbol: F
Measurement: Molar Flow RateUnit: mol/s
Note: Value should be greater than 0.
Distillate Flowrate
The Distillate flowrate from Distillation Column is the amount of moles of condensed top product (distillate) flowing out from the column per unit time.
Symbol: D
Measurement: Molar Flow RateUnit: mol/s
Note: Value should be greater than 0.

Other Formulas to find Residue Flowrate from Distillation Column

​Go Total Residue Flowrate of Distillation Column from Overall Component Material Balance
W=FxF-DxDxW
​Go Total Residue Flowrate of Distillation Column from Overall and Component Material Balance
W=DxD-xFxF-xW

Other formulas in Material Balance category

​Go Total Feed Flowrate of Distillation Column from Overall Material Balance
F=D+W
​Go Total Distillate Flowrate of Distillation Column from Overall Material Balance
D=F-W
​Go Mole Fraction of MVC in Feed from Overall Component Material Balance in Distillation
xF=DxD+WxWF
​Go Mole Fraction of MVC in Distillate from Overall Component Material Balance in Distillation
xD=FxF-WxWD

How to Evaluate Total Residue Flowrate of Distillation Column from Overall Material Balance?

Total Residue Flowrate of Distillation Column from Overall Material Balance evaluator uses Residue Flowrate from Distillation Column = Feed Flowrate to Distillation Column-Distillate Flowrate to evaluate the Residue Flowrate from Distillation Column, The Total Residue Flowrate of Distillation Column from Overall Material Balance formula is defined as the difference between flowrates of feed and distillate in a distillation column. Residue Flowrate from Distillation Column is denoted by W symbol.

How to evaluate Total Residue Flowrate of Distillation Column from Overall Material Balance using this online evaluator? To use this online evaluator for Total Residue Flowrate of Distillation Column from Overall Material Balance, enter Feed Flowrate to Distillation Column (F) & Distillate Flowrate (D) and hit the calculate button.

FAQs on Total Residue Flowrate of Distillation Column from Overall Material Balance

What is the formula to find Total Residue Flowrate of Distillation Column from Overall Material Balance?
The formula of Total Residue Flowrate of Distillation Column from Overall Material Balance is expressed as Residue Flowrate from Distillation Column = Feed Flowrate to Distillation Column-Distillate Flowrate. Here is an example- 5.9 = 10-4.2.
How to calculate Total Residue Flowrate of Distillation Column from Overall Material Balance?
With Feed Flowrate to Distillation Column (F) & Distillate Flowrate (D) we can find Total Residue Flowrate of Distillation Column from Overall Material Balance using the formula - Residue Flowrate from Distillation Column = Feed Flowrate to Distillation Column-Distillate Flowrate.
What are the other ways to Calculate Residue Flowrate from Distillation Column?
Here are the different ways to Calculate Residue Flowrate from Distillation Column-
  • Residue Flowrate from Distillation Column=(Feed Flowrate to Distillation Column*Mole Fraction of More Volatile Component in Feed-Distillate Flowrate*Mole Fraction of More Volatile Comp in Distillate)/Mole Fraction of More Volatile Comp in ResidueOpenImg
  • Residue Flowrate from Distillation Column=Distillate Flowrate*(Mole Fraction of More Volatile Comp in Distillate-Mole Fraction of More Volatile Component in Feed)/(Mole Fraction of More Volatile Component in Feed-Mole Fraction of More Volatile Comp in Residue)OpenImg
Can the Total Residue Flowrate of Distillation Column from Overall Material Balance be negative?
No, the Total Residue Flowrate of Distillation Column from Overall Material Balance, measured in Molar Flow Rate cannot be negative.
Which unit is used to measure Total Residue Flowrate of Distillation Column from Overall Material Balance?
Total Residue Flowrate of Distillation Column from Overall Material Balance is usually measured using the Mole per Second[mol/s] for Molar Flow Rate. Kilomole per Second[mol/s], Dekamole per Second[mol/s], Mole per Minute[mol/s] are the few other units in which Total Residue Flowrate of Distillation Column from Overall Material Balance can be measured.
Copied!