Fx Copy
LaTeX Copy
Total pressure of Gas is the sum of all the forces that the gas molecules exert on the walls of their container. Check FAQs
PT=1(y1P1sat)+(y2P2sat)
PT - Total Pressure of Gas?y1 - Mole Fraction of Component 1 in Vapour Phase?P1sat - Saturated Pressure of Component 1?y2 - Mole Fraction of Component 2 in Vapour Phase?P2sat - Saturated Pressure of Component 2?

Total Pressure for Binary Vapour System for Dew-Bubble Point Calculations with Raoult's Law Example

With values
With units
Only example

Here is how the Total Pressure for Binary Vapour System for Dew-Bubble Point Calculations with Raoult's Law equation looks like with Values.

Here is how the Total Pressure for Binary Vapour System for Dew-Bubble Point Calculations with Raoult's Law equation looks like with Units.

Here is how the Total Pressure for Binary Vapour System for Dew-Bubble Point Calculations with Raoult's Law equation looks like.

11.5385Edit=1(0.5Edit10Edit)+(0.55Edit15Edit)
You are here -
HomeIcon Home » Category Engineering » Category Chemical Engineering » Category Thermodynamics » fx Total Pressure for Binary Vapour System for Dew-Bubble Point Calculations with Raoult's Law

Total Pressure for Binary Vapour System for Dew-Bubble Point Calculations with Raoult's Law Solution

Follow our step by step solution on how to calculate Total Pressure for Binary Vapour System for Dew-Bubble Point Calculations with Raoult's Law?

FIRST Step Consider the formula
PT=1(y1P1sat)+(y2P2sat)
Next Step Substitute values of Variables
PT=1(0.510Pa)+(0.5515Pa)
Next Step Prepare to Evaluate
PT=1(0.510)+(0.5515)
Next Step Evaluate
PT=11.5384615384615Pa
LAST Step Rounding Answer
PT=11.5385Pa

Total Pressure for Binary Vapour System for Dew-Bubble Point Calculations with Raoult's Law Formula Elements

Variables
Total Pressure of Gas
Total pressure of Gas is the sum of all the forces that the gas molecules exert on the walls of their container.
Symbol: PT
Measurement: PressureUnit: Pa
Note: Value can be positive or negative.
Mole Fraction of Component 1 in Vapour Phase
The mole fraction of component 1 in vapour phase can be defined as the ratio of the number of moles a component 1 to the total number of moles of components present in the vapour phase.
Symbol: y1
Measurement: NAUnit: Unitless
Note: Value should be between 0 to 1.
Saturated Pressure of Component 1
Saturated pressure of component 1 is the pressure at which the given component 1 liquid and its vapour or a given solid and its vapour can co-exist in equilibrium, at a given temperature.
Symbol: P1sat
Measurement: PressureUnit: Pa
Note: Value can be positive or negative.
Mole Fraction of Component 2 in Vapour Phase
The Mole Fraction of Component 2 in Vapour Phase can be defined as the ratio of the number of moles a component 2 to the total number of moles of components present in the vapour phase.
Symbol: y2
Measurement: NAUnit: Unitless
Note: Value should be between 0 to 1.
Saturated Pressure of Component 2
Saturated pressure of component 2 is the pressure at which the given component 2 liquid and its vapour or a given solid and its vapour can co-exist in equilibrium, at a given temperature.
Symbol: P2sat
Measurement: PressureUnit: Pa
Note: Value can be positive or negative.

Other Formulas to find Total Pressure of Gas

​Go Total Pressure for Binary Liquid System for Dew-Bubble Point Calculations with Raoult's Law
PT=(x1P1sat)+(x2P2sat)
​Go Total Pressure using Raoult's Law in VLE
PT=xLiquidPsat yGas

Other formulas in Raoult’s Law, Modified Raoult’s Law, and Henry’s Law in VLE category

​Go Liquid Phase Mole Fraction using Raoult's Law in VLE
xLiquid=yGasPTPsat
​Go Saturated Pressure using Raoult's Law in VLE
Psat =yGasPTxLiquid

How to Evaluate Total Pressure for Binary Vapour System for Dew-Bubble Point Calculations with Raoult's Law?

Total Pressure for Binary Vapour System for Dew-Bubble Point Calculations with Raoult's Law evaluator uses Total Pressure of Gas = 1/((Mole Fraction of Component 1 in Vapour Phase/Saturated Pressure of Component 1)+(Mole Fraction of Component 2 in Vapour Phase/Saturated Pressure of Component 2)) to evaluate the Total Pressure of Gas, The Total Pressure for Binary Vapour System for Dew-Bubble Point Calculations with Raoult's Law formula is defined as the reciprocal of the summation of the ratio of mole fraction of i th component to the saturated pressure of i th component, where i = 2 for the binary system. Total Pressure of Gas is denoted by PT symbol.

How to evaluate Total Pressure for Binary Vapour System for Dew-Bubble Point Calculations with Raoult's Law using this online evaluator? To use this online evaluator for Total Pressure for Binary Vapour System for Dew-Bubble Point Calculations with Raoult's Law, enter Mole Fraction of Component 1 in Vapour Phase (y1), Saturated Pressure of Component 1 (P1sat), Mole Fraction of Component 2 in Vapour Phase (y2) & Saturated Pressure of Component 2 (P2sat) and hit the calculate button.

FAQs on Total Pressure for Binary Vapour System for Dew-Bubble Point Calculations with Raoult's Law

What is the formula to find Total Pressure for Binary Vapour System for Dew-Bubble Point Calculations with Raoult's Law?
The formula of Total Pressure for Binary Vapour System for Dew-Bubble Point Calculations with Raoult's Law is expressed as Total Pressure of Gas = 1/((Mole Fraction of Component 1 in Vapour Phase/Saturated Pressure of Component 1)+(Mole Fraction of Component 2 in Vapour Phase/Saturated Pressure of Component 2)). Here is an example- 11.53846 = 1/((0.5/10)+(0.55/15)).
How to calculate Total Pressure for Binary Vapour System for Dew-Bubble Point Calculations with Raoult's Law?
With Mole Fraction of Component 1 in Vapour Phase (y1), Saturated Pressure of Component 1 (P1sat), Mole Fraction of Component 2 in Vapour Phase (y2) & Saturated Pressure of Component 2 (P2sat) we can find Total Pressure for Binary Vapour System for Dew-Bubble Point Calculations with Raoult's Law using the formula - Total Pressure of Gas = 1/((Mole Fraction of Component 1 in Vapour Phase/Saturated Pressure of Component 1)+(Mole Fraction of Component 2 in Vapour Phase/Saturated Pressure of Component 2)).
What are the other ways to Calculate Total Pressure of Gas?
Here are the different ways to Calculate Total Pressure of Gas-
  • Total Pressure of Gas=(Mole Fraction of Component 1 in Liquid Phase*Saturated Pressure of Component 1)+(Mole Fraction of Component 2 in Liquid Phase*Saturated Pressure of Component 2)OpenImg
  • Total Pressure of Gas=(Mole Fraction of Component in Liquid Phase*Saturated pressure)/Mole Fraction of Component in Vapor PhaseOpenImg
Can the Total Pressure for Binary Vapour System for Dew-Bubble Point Calculations with Raoult's Law be negative?
Yes, the Total Pressure for Binary Vapour System for Dew-Bubble Point Calculations with Raoult's Law, measured in Pressure can be negative.
Which unit is used to measure Total Pressure for Binary Vapour System for Dew-Bubble Point Calculations with Raoult's Law?
Total Pressure for Binary Vapour System for Dew-Bubble Point Calculations with Raoult's Law is usually measured using the Pascal[Pa] for Pressure. Kilopascal[Pa], Bar[Pa], Pound Per Square Inch[Pa] are the few other units in which Total Pressure for Binary Vapour System for Dew-Bubble Point Calculations with Raoult's Law can be measured.
Copied!