Total Power Factor for Continuous Load Current Formula

Fx Copy
LaTeX Copy
The Power Factor Full Converter is defined as the ratio of the real power absorbed by the load to the apparent power flowing in a full converter circuit. Check FAQs
cosΦ(full)=cos(αfull)
cosΦ(full) - Power Factor Full Converter?αfull - Firing Angle Full Converter?

Total Power Factor for Continuous Load Current Example

With values
With units
Only example

Here is how the Total Power Factor for Continuous Load Current equation looks like with Values.

Here is how the Total Power Factor for Continuous Load Current equation looks like with Units.

Here is how the Total Power Factor for Continuous Load Current equation looks like.

0.8192Edit=cos(35Edit)
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power Electronics » fx Total Power Factor for Continuous Load Current

Total Power Factor for Continuous Load Current Solution

Follow our step by step solution on how to calculate Total Power Factor for Continuous Load Current?

FIRST Step Consider the formula
cosΦ(full)=cos(αfull)
Next Step Substitute values of Variables
cosΦ(full)=cos(35°)
Next Step Convert Units
cosΦ(full)=cos(0.6109rad)
Next Step Prepare to Evaluate
cosΦ(full)=cos(0.6109)
Next Step Evaluate
cosΦ(full)=0.819152044289057
LAST Step Rounding Answer
cosΦ(full)=0.8192

Total Power Factor for Continuous Load Current Formula Elements

Variables
Functions
Power Factor Full Converter
The Power Factor Full Converter is defined as the ratio of the real power absorbed by the load to the apparent power flowing in a full converter circuit.
Symbol: cosΦ(full)
Measurement: NAUnit: Unitless
Note: Value should be less than 1.
Firing Angle Full Converter
Firing Angle Full Converter refers to the point within each AC voltage cycle at which the thyristors are triggered to conduct current in a full converter.
Symbol: αfull
Measurement: AngleUnit: °
Note: Value should be less than 180.
cos
Cosine of an angle is the ratio of the side adjacent to the angle to the hypotenuse of the triangle.
Syntax: cos(Angle)

Other formulas in Single Phase Full Converter category

​Go Average DC Output Voltage of Single Phase Full Converter
Vavg-dc(full)=2Vm-dc(full)cos(αfull)π
​Go Maximum Output DC Voltage of Single Phase Full Converter
Vm-dc(full)=2Vm(full)π
​Go RMS Output Voltage of Single Phase Full Converter
Vrms(full)=Vm(full)2
​Go Apparent Power for Constant Load Current
S(full)=IL(full)VL(full)

How to Evaluate Total Power Factor for Continuous Load Current?

Total Power Factor for Continuous Load Current evaluator uses Power Factor Full Converter = cos(Firing Angle Full Converter) to evaluate the Power Factor Full Converter, The Total power factor for continuous load current formula is the product of the displacement power factor and distortion power factor. It can also be calculated by finding the ratio of real power and apparent power. Power Factor Full Converter is denoted by cosΦ(full) symbol.

How to evaluate Total Power Factor for Continuous Load Current using this online evaluator? To use this online evaluator for Total Power Factor for Continuous Load Current, enter Firing Angle Full Converter full) and hit the calculate button.

FAQs on Total Power Factor for Continuous Load Current

What is the formula to find Total Power Factor for Continuous Load Current?
The formula of Total Power Factor for Continuous Load Current is expressed as Power Factor Full Converter = cos(Firing Angle Full Converter). Here is an example- 0.819152 = cos(0.610865238197901).
How to calculate Total Power Factor for Continuous Load Current?
With Firing Angle Full Converter full) we can find Total Power Factor for Continuous Load Current using the formula - Power Factor Full Converter = cos(Firing Angle Full Converter). This formula also uses Cosine (cos) function(s).
Copied!