Total Power Accepted by Fiber Formula

Fx Copy
LaTeX Copy
Total Power Accepted by Fiber refers to the amount of optical power that successfully travels from the emitting fiber to the receiving fiber. Check FAQs
Pto=Po(1-8dax3πrcore)
Pto - Total Power Accepted by Fiber?Po - Incident Power?dax - Axial Displacement?rcore - Radius of Core?π - Archimedes' constant?

Total Power Accepted by Fiber Example

With values
With units
Only example

Here is how the Total Power Accepted by Fiber equation looks like with Values.

Here is how the Total Power Accepted by Fiber equation looks like with Units.

Here is how the Total Power Accepted by Fiber equation looks like.

1.5192Edit=1.75Edit(1-82.02Edit33.141613Edit)
You are here -
HomeIcon Home » Category Engineering » Category Electronics » Category Fiber Optic Transmission » fx Total Power Accepted by Fiber

Total Power Accepted by Fiber Solution

Follow our step by step solution on how to calculate Total Power Accepted by Fiber?

FIRST Step Consider the formula
Pto=Po(1-8dax3πrcore)
Next Step Substitute values of Variables
Pto=1.75µW(1-82.02μm3π13μm)
Next Step Substitute values of Constants
Pto=1.75µW(1-82.02μm33.141613μm)
Next Step Convert Units
Pto=1.8E-6W(1-82E-6m33.14161.3E-5m)
Next Step Prepare to Evaluate
Pto=1.8E-6(1-82E-633.14161.3E-5)
Next Step Evaluate
Pto=1.51918452355698E-06W
Next Step Convert to Output's Unit
Pto=1.51918452355698µW
LAST Step Rounding Answer
Pto=1.5192µW

Total Power Accepted by Fiber Formula Elements

Variables
Constants
Total Power Accepted by Fiber
Total Power Accepted by Fiber refers to the amount of optical power that successfully travels from the emitting fiber to the receiving fiber.
Symbol: Pto
Measurement: PowerUnit: µW
Note: Value should be greater than 0.
Incident Power
Incident Power w.r.t optics is the amount of optical power (light energy) incident on the photodetector.
Symbol: Po
Measurement: PowerUnit: µW
Note: Value should be greater than 0.
Axial Displacement
Axial Displacement represents the axial misalignment between the two fibers. It’s the distance by which one fiber is offset from the other along the axis of the fiber.
Symbol: dax
Measurement: LengthUnit: μm
Note: Value should be greater than 0.
Radius of Core
Radius of Core is the length measured from the center of the core to the core-cladding interface.
Symbol: rcore
Measurement: LengthUnit: μm
Note: Value should be greater than 0.
Archimedes' constant
Archimedes' constant is a mathematical constant that represents the ratio of the circumference of a circle to its diameter.
Symbol: π
Value: 3.14159265358979323846264338327950288

Other formulas in Optical Detectors category

​Go Quantum Efficiency of Photodetector
η=NeNp
​Go Incident Photon Rate
Ri=Pi[hP]Fi
​Go Electron Rate in Detector
Rp=ηRi
​Go Long Wavelength Cutoff Point
λc=[hP][c]Eg

How to Evaluate Total Power Accepted by Fiber?

Total Power Accepted by Fiber evaluator uses Total Power Accepted by Fiber = Incident Power*(1-(8*Axial Displacement)/(3*pi*Radius of Core)) to evaluate the Total Power Accepted by Fiber, Total Power Accepted by Fiber refers to the amount of optical power that successfully travels from the emitting fiber (the fiber sending the light) to the receiving fiber (the fiber receiving the light). This power is influenced by factors such as the alignment of the fibers and the gap between them. If there is a misalignment or a gap, some of the light may not enter the receiving fiber, resulting in a loss of power. Total Power Accepted by Fiber is denoted by Pto symbol.

How to evaluate Total Power Accepted by Fiber using this online evaluator? To use this online evaluator for Total Power Accepted by Fiber, enter Incident Power (Po), Axial Displacement (dax) & Radius of Core (rcore) and hit the calculate button.

FAQs on Total Power Accepted by Fiber

What is the formula to find Total Power Accepted by Fiber?
The formula of Total Power Accepted by Fiber is expressed as Total Power Accepted by Fiber = Incident Power*(1-(8*Axial Displacement)/(3*pi*Radius of Core)). Here is an example- 1.5E-6 = 1.75E-06*(1-(8*2.02E-06)/(3*pi*1.3E-05)).
How to calculate Total Power Accepted by Fiber?
With Incident Power (Po), Axial Displacement (dax) & Radius of Core (rcore) we can find Total Power Accepted by Fiber using the formula - Total Power Accepted by Fiber = Incident Power*(1-(8*Axial Displacement)/(3*pi*Radius of Core)). This formula also uses Archimedes' constant .
Can the Total Power Accepted by Fiber be negative?
No, the Total Power Accepted by Fiber, measured in Power cannot be negative.
Which unit is used to measure Total Power Accepted by Fiber?
Total Power Accepted by Fiber is usually measured using the Microwatt[µW] for Power. Watt[µW], Kilowatt[µW], Milliwatt[µW] are the few other units in which Total Power Accepted by Fiber can be measured.
Copied!