Total Energy is the sum of the kinetic energy and the potential energy of the system under consideration. Check FAQs
Etotal=(VFN22[g])+df
Etotal - Total Energy?VFN - Mean Velocity for Froude Number?df - Depth of Flow?[g] - Gravitational acceleration on Earth?

Total Energy per unit Weight of Water in Flow Section considering Bed Slope as Datum Example

With values
With units
Only example

Here is how the Total Energy per unit Weight of Water in Flow Section considering Bed Slope as Datum equation looks like with Values.

Here is how the Total Energy per unit Weight of Water in Flow Section considering Bed Slope as Datum equation looks like with Units.

Here is how the Total Energy per unit Weight of Water in Flow Section considering Bed Slope as Datum equation looks like.

253.1305Edit=(70Edit229.8066)+3.3Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Hydraulics and Waterworks » fx Total Energy per unit Weight of Water in Flow Section considering Bed Slope as Datum

Total Energy per unit Weight of Water in Flow Section considering Bed Slope as Datum Solution

Follow our step by step solution on how to calculate Total Energy per unit Weight of Water in Flow Section considering Bed Slope as Datum?

FIRST Step Consider the formula
Etotal=(VFN22[g])+df
Next Step Substitute values of Variables
Etotal=(70m/s22[g])+3.3m
Next Step Substitute values of Constants
Etotal=(70m/s229.8066m/s²)+3.3m
Next Step Prepare to Evaluate
Etotal=(70229.8066)+3.3
Next Step Evaluate
Etotal=253.130472179592J
LAST Step Rounding Answer
Etotal=253.1305J

Total Energy per unit Weight of Water in Flow Section considering Bed Slope as Datum Formula Elements

Variables
Constants
Total Energy
Total Energy is the sum of the kinetic energy and the potential energy of the system under consideration.
Symbol: Etotal
Measurement: EnergyUnit: J
Note: Value should be greater than 0.
Mean Velocity for Froude Number
Mean Velocity for Froude Number is defined as the average velocity of a fluid at a point and over an arbitrary time T.
Symbol: VFN
Measurement: SpeedUnit: m/s
Note: Value can be positive or negative.
Depth of Flow
Depth of Flow is the distance from the top or surface of the flow to the bottom of a channel or other waterway or Depth of Flow at the Vertical while measuring Sound Weights.
Symbol: df
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Gravitational acceleration on Earth
Gravitational acceleration on Earth means that the velocity of an object in free fall will increase by 9.8 m/s2 every second.
Symbol: [g]
Value: 9.80665 m/s²

Other Formulas to find Total Energy

​Go Total Energy per unit Weight of Water in Flow Section
Etotal=(Vmean22[g])+df+y
​Go Total Energy per unit Weight of Water in Flow Section given Discharge
Etotal=df+((QAcs)22[g])

Other formulas in Specific Energy and Critical Depth category

​Go Datum Height for Total Energy per unit Weight of Water in Flow Section
y=Etotal-((Vmean22[g])+df)
​Go Mean Velocity of Flow for Total Energy per Unit Weight of Water in Flow Section
Vmean=(Etotal-(df+y))2[g]
​Go Depth of Flow given Total Energy per Unit Weight of Water in Flow Section
df=Etotal-((Vmean22[g])+y)
​Go Mean Velocity of flow given Total Energy in flow section taking Bed Slope as Datum
Vmean=(Etotal-(df))2[g]

How to Evaluate Total Energy per unit Weight of Water in Flow Section considering Bed Slope as Datum?

Total Energy per unit Weight of Water in Flow Section considering Bed Slope as Datum evaluator uses Total Energy = ((Mean Velocity for Froude Number^2)/(2*[g]))+Depth of Flow to evaluate the Total Energy, The Total Energy per unit Weight of Water in Flow Section considering Bed Slope as Datum is defined as the sum of kinetic and potential energy stored in flowing water in channel. Total Energy is denoted by Etotal symbol.

How to evaluate Total Energy per unit Weight of Water in Flow Section considering Bed Slope as Datum using this online evaluator? To use this online evaluator for Total Energy per unit Weight of Water in Flow Section considering Bed Slope as Datum, enter Mean Velocity for Froude Number (VFN) & Depth of Flow (df) and hit the calculate button.

FAQs on Total Energy per unit Weight of Water in Flow Section considering Bed Slope as Datum

What is the formula to find Total Energy per unit Weight of Water in Flow Section considering Bed Slope as Datum?
The formula of Total Energy per unit Weight of Water in Flow Section considering Bed Slope as Datum is expressed as Total Energy = ((Mean Velocity for Froude Number^2)/(2*[g]))+Depth of Flow. Here is an example- 130.7645 = ((70^2)/(2*[g]))+3.3.
How to calculate Total Energy per unit Weight of Water in Flow Section considering Bed Slope as Datum?
With Mean Velocity for Froude Number (VFN) & Depth of Flow (df) we can find Total Energy per unit Weight of Water in Flow Section considering Bed Slope as Datum using the formula - Total Energy = ((Mean Velocity for Froude Number^2)/(2*[g]))+Depth of Flow. This formula also uses Gravitational acceleration on Earth constant(s).
What are the other ways to Calculate Total Energy?
Here are the different ways to Calculate Total Energy-
  • Total Energy=((Mean Velocity^2)/(2*[g]))+Depth of Flow+Height above DatumOpenImg
  • Total Energy=Depth of Flow+(((Discharge of Channel/Cross-Sectional Area of Channel)^2)/(2*[g]))OpenImg
Can the Total Energy per unit Weight of Water in Flow Section considering Bed Slope as Datum be negative?
No, the Total Energy per unit Weight of Water in Flow Section considering Bed Slope as Datum, measured in Energy cannot be negative.
Which unit is used to measure Total Energy per unit Weight of Water in Flow Section considering Bed Slope as Datum?
Total Energy per unit Weight of Water in Flow Section considering Bed Slope as Datum is usually measured using the Joule[J] for Energy. Kilojoule[J], Gigajoule[J], Megajoule[J] are the few other units in which Total Energy per unit Weight of Water in Flow Section considering Bed Slope as Datum can be measured.
Copied!