Time of Dialysis using Hollow Fiber Haemodialyser Formula

Fx Copy
LaTeX Copy
Time of dialysis is the time required for completion of dialysis process. Check FAQs
t=(VbQb)ln(C1C2)((1-(e-NT))-1)
t - Time of Dialysis?Vb - Volume of blood?Qb - Volumetric Rate of Blood?C1 - Initial Concentration In Blood?C2 - Final Concentration In Blood?NT - No of Transfer Units?

Time of Dialysis using Hollow Fiber Haemodialyser Example

With values
With units
Only example

Here is how the Time of Dialysis using Hollow Fiber Haemodialyser equation looks like with Values.

Here is how the Time of Dialysis using Hollow Fiber Haemodialyser equation looks like with Units.

Here is how the Time of Dialysis using Hollow Fiber Haemodialyser equation looks like.

2.6745Edit=(0.005Edit4.7E-6Edit)ln(200Edit20Edit)((1-(e-0.296Edit))-1)
You are here -
HomeIcon Home » Category Engineering » Category Chemical Engineering » Category Mass Transfer Operations » fx Time of Dialysis using Hollow Fiber Haemodialyser

Time of Dialysis using Hollow Fiber Haemodialyser Solution

Follow our step by step solution on how to calculate Time of Dialysis using Hollow Fiber Haemodialyser?

FIRST Step Consider the formula
t=(VbQb)ln(C1C2)((1-(e-NT))-1)
Next Step Substitute values of Variables
t=(0.0054.7E-6m³/s)ln(200mg20mg)((1-(e-0.296))-1)
Next Step Prepare to Evaluate
t=(0.0054.7E-6)ln(20020)((1-(e-0.296))-1)
Next Step Evaluate
t=9628.25216598987s
Next Step Convert to Output's Unit
t=2.67451449055274h
LAST Step Rounding Answer
t=2.6745h

Time of Dialysis using Hollow Fiber Haemodialyser Formula Elements

Variables
Functions
Time of Dialysis
Time of dialysis is the time required for completion of dialysis process.
Symbol: t
Measurement: TimeUnit: h
Note: Value should be greater than 0.
Volume of blood
Volume of blood is the total amount blood circulating within circulatory system.
Symbol: Vb
Measurement: VolumeUnit:
Note: Value should be greater than 0.
Volumetric Rate of Blood
Volumetric Rate of blood is defined as amount of blood passes through a specific point in the circulatory system per unit of time.
Symbol: Qb
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Initial Concentration In Blood
Initial Concentration in blood is defined as the amount of component present in blood in mg.
Symbol: C1
Measurement: WeightUnit: mg
Note: Value should be greater than 0.
Final Concentration In Blood
Final Concentration in blood is defined as the amount of component present in blood after dialysis in mg.
Symbol: C2
Measurement: WeightUnit: mg
Note: Value should be greater than 0.
No of Transfer Units
No of Transfer Units is defined as the as the number of stages required for haemodialysis.
Symbol: NT
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
ln
The natural logarithm, also known as the logarithm to the base e, is the inverse function of the natural exponential function.
Syntax: ln(Number)

Other formulas in Basics of Membrane Separation Processes category

​Go Hagen Poiseuille Based Flux for Membrane Separation
JwM=εd2ΔPm32μΤlmt
​Go Resistance to flow in Membranes
Rm=ΔPmμJwM
​Go Liquid Viscosity based on Membrane Resistance
μ=ΔPmRmJwM
​Go Membrane Flux Based on Resistance
JwM=ΔPmRmμ

How to Evaluate Time of Dialysis using Hollow Fiber Haemodialyser?

Time of Dialysis using Hollow Fiber Haemodialyser evaluator uses Time of Dialysis = (Volume of blood/Volumetric Rate of Blood)*ln(Initial Concentration In Blood/Final Concentration In Blood)*((1-(e^-No of Transfer Units))^-1) to evaluate the Time of Dialysis, Time of Dialysis using Hollow Fiber Haemodialyser means time required to carry out dialysis process using a haemodialysis membrane. Time of Dialysis is denoted by t symbol.

How to evaluate Time of Dialysis using Hollow Fiber Haemodialyser using this online evaluator? To use this online evaluator for Time of Dialysis using Hollow Fiber Haemodialyser, enter Volume of blood (Vb), Volumetric Rate of Blood (Qb), Initial Concentration In Blood (C1), Final Concentration In Blood (C2) & No of Transfer Units (NT) and hit the calculate button.

FAQs on Time of Dialysis using Hollow Fiber Haemodialyser

What is the formula to find Time of Dialysis using Hollow Fiber Haemodialyser?
The formula of Time of Dialysis using Hollow Fiber Haemodialyser is expressed as Time of Dialysis = (Volume of blood/Volumetric Rate of Blood)*ln(Initial Concentration In Blood/Final Concentration In Blood)*((1-(e^-No of Transfer Units))^-1). Here is an example- 0.000743 = (0.005/4.667E-06)*ln(0.0002/2E-05)*((1-(e^-0.296))^-1).
How to calculate Time of Dialysis using Hollow Fiber Haemodialyser?
With Volume of blood (Vb), Volumetric Rate of Blood (Qb), Initial Concentration In Blood (C1), Final Concentration In Blood (C2) & No of Transfer Units (NT) we can find Time of Dialysis using Hollow Fiber Haemodialyser using the formula - Time of Dialysis = (Volume of blood/Volumetric Rate of Blood)*ln(Initial Concentration In Blood/Final Concentration In Blood)*((1-(e^-No of Transfer Units))^-1). This formula also uses Natural Logarithm (ln) function(s).
Can the Time of Dialysis using Hollow Fiber Haemodialyser be negative?
Yes, the Time of Dialysis using Hollow Fiber Haemodialyser, measured in Time can be negative.
Which unit is used to measure Time of Dialysis using Hollow Fiber Haemodialyser?
Time of Dialysis using Hollow Fiber Haemodialyser is usually measured using the Hour[h] for Time. Second[h], Millisecond[h], Microsecond[h] are the few other units in which Time of Dialysis using Hollow Fiber Haemodialyser can be measured.
Copied!