Time at which Drawdowns are measured for Storage Coefficient Formula

Fx Copy
LaTeX Copy
The Total Drawdown is referred as reduction in hydraulic head observed at a well in an aquifer, typically due to pumping a well as part of an aquifer test or well test. Check FAQs
st=Sro22.25T
st - Total Drawdown?S - Storage Coefficient?ro - Distance from Pumping Well to Point Intersection?T - Transmissivity?

Time at which Drawdowns are measured for Storage Coefficient Example

With values
With units
Only example

Here is how the Time at which Drawdowns are measured for Storage Coefficient equation looks like with Values.

Here is how the Time at which Drawdowns are measured for Storage Coefficient equation looks like with Units.

Here is how the Time at which Drawdowns are measured for Storage Coefficient equation looks like.

0.0352Edit=0.0545Edit4Edit22.2511Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Engineering Hydrology » fx Time at which Drawdowns are measured for Storage Coefficient

Time at which Drawdowns are measured for Storage Coefficient Solution

Follow our step by step solution on how to calculate Time at which Drawdowns are measured for Storage Coefficient?

FIRST Step Consider the formula
st=Sro22.25T
Next Step Substitute values of Variables
st=0.05454m22.2511m²/s
Next Step Prepare to Evaluate
st=0.0545422.2511
Next Step Evaluate
st=0.0352323232323232m
LAST Step Rounding Answer
st=0.0352m

Time at which Drawdowns are measured for Storage Coefficient Formula Elements

Variables
Total Drawdown
The Total Drawdown is referred as reduction in hydraulic head observed at a well in an aquifer, typically due to pumping a well as part of an aquifer test or well test.
Symbol: st
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Storage Coefficient
The Storage Coefficient is referred as volume of water released from storage per unit decline in hydraulic head in the aquifer, per unit area of the aquifer.
Symbol: S
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Distance from Pumping Well to Point Intersection
The Distance from Pumping Well to Point Intersection is referred as the straight line which intersects the zero-drawdown line.
Symbol: ro
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Transmissivity
Transmissivity is the rate at which groundwater flows horizontally through an aquifer or the degree to which a medium allows something, in particular electromagnetic radiation, to pass through it.
Symbol: T
Measurement: Kinematic ViscosityUnit: m²/s
Note: Value can be positive or negative.

Other formulas in Distance Drawdown Analysis category

​Go Transmissivity from Distance Drawdown Graphs
T=2.3q2πΔsD
​Go Storage Coefficient from Distance-Drawdown Graphs
S=2.25Tstro2
​Go Pumping Rate from Distance Drawdown Graphs
q=T2πΔsD2.3
​Go Drawdown across One Log Cycle from Distance Drawdown Graphs given Transmissivity
ΔsD=2.3qT2π

How to Evaluate Time at which Drawdowns are measured for Storage Coefficient?

Time at which Drawdowns are measured for Storage Coefficient evaluator uses Total Drawdown = Storage Coefficient*Distance from Pumping Well to Point Intersection^2/(2.25*Transmissivity) to evaluate the Total Drawdown, The Time at which Drawdowns are measured for Storage Coefficient formula is defined as the time at which the reduction in hydraulic head observed at a well in an aquifer, typically due to pumping a well as part of an aquifer test or well test. Total Drawdown is denoted by st symbol.

How to evaluate Time at which Drawdowns are measured for Storage Coefficient using this online evaluator? To use this online evaluator for Time at which Drawdowns are measured for Storage Coefficient, enter Storage Coefficient (S), Distance from Pumping Well to Point Intersection (ro) & Transmissivity (T) and hit the calculate button.

FAQs on Time at which Drawdowns are measured for Storage Coefficient

What is the formula to find Time at which Drawdowns are measured for Storage Coefficient?
The formula of Time at which Drawdowns are measured for Storage Coefficient is expressed as Total Drawdown = Storage Coefficient*Distance from Pumping Well to Point Intersection^2/(2.25*Transmissivity). Here is an example- 0.035232 = 0.0545*4^2/(2.25*11).
How to calculate Time at which Drawdowns are measured for Storage Coefficient?
With Storage Coefficient (S), Distance from Pumping Well to Point Intersection (ro) & Transmissivity (T) we can find Time at which Drawdowns are measured for Storage Coefficient using the formula - Total Drawdown = Storage Coefficient*Distance from Pumping Well to Point Intersection^2/(2.25*Transmissivity).
Can the Time at which Drawdowns are measured for Storage Coefficient be negative?
Yes, the Time at which Drawdowns are measured for Storage Coefficient, measured in Length can be negative.
Which unit is used to measure Time at which Drawdowns are measured for Storage Coefficient?
Time at which Drawdowns are measured for Storage Coefficient is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Time at which Drawdowns are measured for Storage Coefficient can be measured.
Copied!