Time at 2nd Instance since Pumping Started given Discharge Formula

Fx Copy
LaTeX Copy
Time of Drawdown is the total period for the difference between the pumping water level and the static (non-pumping) water level. Check FAQs
t2=t110Δs2.303Q4πtseconds
t2 - Time of Drawdown?t1 - Time of Drawdown (t1) in Wells?Δs - Difference in Drawdowns?Q - Discharge?tseconds - Time in Seconds?π - Archimedes' constant?

Time at 2nd Instance since Pumping Started given Discharge Example

With values
With units
Only example

Here is how the Time at 2nd Instance since Pumping Started given Discharge equation looks like with Values.

Here is how the Time at 2nd Instance since Pumping Started given Discharge equation looks like with Units.

Here is how the Time at 2nd Instance since Pumping Started given Discharge equation looks like.

236.4383Edit=58.7Edit100.014Edit2.3031.01Edit43.14168Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Time at 2nd Instance since Pumping Started given Discharge

Time at 2nd Instance since Pumping Started given Discharge Solution

Follow our step by step solution on how to calculate Time at 2nd Instance since Pumping Started given Discharge?

FIRST Step Consider the formula
t2=t110Δs2.303Q4πtseconds
Next Step Substitute values of Variables
t2=58.7s100.014m2.3031.01m³/s4π8s
Next Step Substitute values of Constants
t2=58.7s100.014m2.3031.01m³/s43.14168s
Next Step Prepare to Evaluate
t2=58.7100.0142.3031.0143.14168
Next Step Evaluate
t2=236.438279349223s
LAST Step Rounding Answer
t2=236.4383s

Time at 2nd Instance since Pumping Started given Discharge Formula Elements

Variables
Constants
Time of Drawdown
Time of Drawdown is the total period for the difference between the pumping water level and the static (non-pumping) water level.
Symbol: t2
Measurement: TimeUnit: s
Note: Value should be greater than 0.
Time of Drawdown (t1) in Wells
Time of Drawdown (t1) in Wells is the total period for the difference between the pumping water level and the static (non-pumping) water level for wells.
Symbol: t1
Measurement: TimeUnit: s
Note: Value should be greater than 0.
Difference in Drawdowns
Difference in Drawdowns between the two wells.
Symbol: Δs
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Discharge
Discharge is the rate of flow of a fluid in unsteady flow.
Symbol: Q
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value can be positive or negative.
Time in Seconds
Time in Seconds is the continued sequence of existence and events that occurs in an apparently irreversible succession from the past, through the present, into the future, measured in seconds.
Symbol: tseconds
Measurement: TimeUnit: s
Note: Value should be greater than 0.
Archimedes' constant
Archimedes' constant is a mathematical constant that represents the ratio of the circumference of a circle to its diameter.
Symbol: π
Value: 3.14159265358979323846264338327950288

Other formulas in Time of Flow category

​Go Time given Formation Constant S
tdays=Sc4uT(dradial)2
​Go Time in Days given Radial Distance
tdays=Sc2.25T(dradial)2
​Go Time in Hours given Time at 1st and 2nd Instance since Pumping Started
thour=2.303Qlog((t2sect1),10)4πΔs
​Go Time at 1st Instance since Pumping Started given Discharge
t1=t210Δs2.303Q4πtseconds

How to Evaluate Time at 2nd Instance since Pumping Started given Discharge?

Time at 2nd Instance since Pumping Started given Discharge evaluator uses Time of Drawdown = Time of Drawdown (t1) in Wells*10^(Difference in Drawdowns/((2.303*Discharge)/(4*pi*Time in Seconds))) to evaluate the Time of Drawdown, Time at 2nd Instance since Pumping Started given Discharge formula is defined as a measure of the time elapsed at the second instance since pumping started, which is crucial in unsteady flow contexts, particularly in understanding the dynamics of fluid flow and pressure changes over time. Time of Drawdown is denoted by t2 symbol.

How to evaluate Time at 2nd Instance since Pumping Started given Discharge using this online evaluator? To use this online evaluator for Time at 2nd Instance since Pumping Started given Discharge, enter Time of Drawdown (t1) in Wells (t1), Difference in Drawdowns (Δs), Discharge (Q) & Time in Seconds (tseconds) and hit the calculate button.

FAQs on Time at 2nd Instance since Pumping Started given Discharge

What is the formula to find Time at 2nd Instance since Pumping Started given Discharge?
The formula of Time at 2nd Instance since Pumping Started given Discharge is expressed as Time of Drawdown = Time of Drawdown (t1) in Wells*10^(Difference in Drawdowns/((2.303*Discharge)/(4*pi*Time in Seconds))). Here is an example- 236.4383 = 58.7*10^(0.014/((2.303*1.01)/(4*pi*8))).
How to calculate Time at 2nd Instance since Pumping Started given Discharge?
With Time of Drawdown (t1) in Wells (t1), Difference in Drawdowns (Δs), Discharge (Q) & Time in Seconds (tseconds) we can find Time at 2nd Instance since Pumping Started given Discharge using the formula - Time of Drawdown = Time of Drawdown (t1) in Wells*10^(Difference in Drawdowns/((2.303*Discharge)/(4*pi*Time in Seconds))). This formula also uses Archimedes' constant .
Can the Time at 2nd Instance since Pumping Started given Discharge be negative?
No, the Time at 2nd Instance since Pumping Started given Discharge, measured in Time cannot be negative.
Which unit is used to measure Time at 2nd Instance since Pumping Started given Discharge?
Time at 2nd Instance since Pumping Started given Discharge is usually measured using the Second[s] for Time. Millisecond[s], Microsecond[s], Nanosecond[s] are the few other units in which Time at 2nd Instance since Pumping Started given Discharge can be measured.
Copied!