Thickness of Plane Wall for Conduction through Wall Formula

Fx Copy
LaTeX Copy
Length is the measurement or extent of something from end to end. Check FAQs
L=(Ti-To)kAw1Q
L - Length?Ti - Inner Surface Temperature?To - Outer Surface Temperature?k - Thermal Conductivity?Aw1 - Area of Wall?Q - Heat Flow Rate?

Thickness of Plane Wall for Conduction through Wall Example

With values
With units
Only example

Here is how the Thickness of Plane Wall for Conduction through Wall equation looks like with Values.

Here is how the Thickness of Plane Wall for Conduction through Wall equation looks like with Units.

Here is how the Thickness of Plane Wall for Conduction through Wall equation looks like.

3Edit=(400.75Edit-400Edit)10Edit50Edit125Edit
You are here -
HomeIcon Home » Category Physics » Category Mechanical » Category Heat and Mass Transfer » fx Thickness of Plane Wall for Conduction through Wall

Thickness of Plane Wall for Conduction through Wall Solution

Follow our step by step solution on how to calculate Thickness of Plane Wall for Conduction through Wall?

FIRST Step Consider the formula
L=(Ti-To)kAw1Q
Next Step Substitute values of Variables
L=(400.75K-400K)10W/(m*K)50125W
Next Step Prepare to Evaluate
L=(400.75-400)1050125
LAST Step Evaluate
L=3m

Thickness of Plane Wall for Conduction through Wall Formula Elements

Variables
Length
Length is the measurement or extent of something from end to end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Inner Surface Temperature
Inner Surface Temperature is the temperature at the inner surface of the wall (either plane wall or cylindrical wall or spherical wall, etc).
Symbol: Ti
Measurement: TemperatureUnit: K
Note: Value can be positive or negative.
Outer Surface Temperature
Outer Surface Temperature is the temperature at the outer surface of the wall either plane wall or cylindrical wall or spherical wall, etc.
Symbol: To
Measurement: TemperatureUnit: K
Note: Value should be greater than 0.
Thermal Conductivity
Thermal Conductivity is rate of heat passes through specified material, expressed as amount of heat flows per unit time through a unit area with a temperature gradient of one degree per unit distance.
Symbol: k
Measurement: Thermal ConductivityUnit: W/(m*K)
Note: Value should be greater than 0.
Area of Wall
Area of Wall refers to the surface area of the wall, which is the total amount of space that it occupies. It is typically measured in square units such as square feet or square meters.
Symbol: Aw1
Measurement: AreaUnit:
Note: Value should be greater than 0.
Heat Flow Rate
Heat Flow Rate is the amount of heat that is transferred per unit of time in some material, usually measured in watt. Heat is the flow of thermal energy driven by thermal non-equilibrium.
Symbol: Q
Measurement: PowerUnit: W
Note: Value can be positive or negative.

Other formulas in Single Plane Wall category

​Go Thermal Resistance of Wall
Rth=LkA
​Go Area of Plane Wall Required for Given Temperature Difference
Aw1=QLk(Ti-To)
​Go Thermal Conductivity of Material Required to Maintain Given Temperature Difference
k=QL(Ti-To)Aw1
​Go Outer Surface Temperature of Wall in Conduction through Wall
To=Ti-QLkAw1

How to Evaluate Thickness of Plane Wall for Conduction through Wall?

Thickness of Plane Wall for Conduction through Wall evaluator uses Length = ((Inner Surface Temperature-Outer Surface Temperature)*Thermal Conductivity*Area of Wall)/Heat Flow Rate to evaluate the Length, The Thickness of Plane Wall for Conduction through Wall formula is defined as the thickness of the wall required to maintain a given temperature at a given heat flow rate through the area of the given material. Length is denoted by L symbol.

How to evaluate Thickness of Plane Wall for Conduction through Wall using this online evaluator? To use this online evaluator for Thickness of Plane Wall for Conduction through Wall, enter Inner Surface Temperature (Ti), Outer Surface Temperature (To), Thermal Conductivity (k), Area of Wall (Aw1) & Heat Flow Rate (Q) and hit the calculate button.

FAQs on Thickness of Plane Wall for Conduction through Wall

What is the formula to find Thickness of Plane Wall for Conduction through Wall?
The formula of Thickness of Plane Wall for Conduction through Wall is expressed as Length = ((Inner Surface Temperature-Outer Surface Temperature)*Thermal Conductivity*Area of Wall)/Heat Flow Rate. Here is an example- 160 = ((400.75-400)*10*50)/125.
How to calculate Thickness of Plane Wall for Conduction through Wall?
With Inner Surface Temperature (Ti), Outer Surface Temperature (To), Thermal Conductivity (k), Area of Wall (Aw1) & Heat Flow Rate (Q) we can find Thickness of Plane Wall for Conduction through Wall using the formula - Length = ((Inner Surface Temperature-Outer Surface Temperature)*Thermal Conductivity*Area of Wall)/Heat Flow Rate.
Can the Thickness of Plane Wall for Conduction through Wall be negative?
No, the Thickness of Plane Wall for Conduction through Wall, measured in Length cannot be negative.
Which unit is used to measure Thickness of Plane Wall for Conduction through Wall?
Thickness of Plane Wall for Conduction through Wall is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Thickness of Plane Wall for Conduction through Wall can be measured.
Copied!