Fx Copy
LaTeX Copy
The Thickness of Aquifer vertical thickness of the hydro geologically defined aquifer in which the pore spaces of the rock forming the aquifer are filled with water. Check FAQs
b=st+hw
b - Thickness of Aquifer?st - Total Drawdown?hw - Depth of Water?

Thickness of Aquifer given Drawdown Value measured at Well Example

With values
With units
Only example

Here is how the Thickness of Aquifer given Drawdown Value measured at Well equation looks like with Values.

Here is how the Thickness of Aquifer given Drawdown Value measured at Well equation looks like with Units.

Here is how the Thickness of Aquifer given Drawdown Value measured at Well equation looks like.

3.27Edit=0.83Edit+2.44Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Thickness of Aquifer given Drawdown Value measured at Well

Thickness of Aquifer given Drawdown Value measured at Well Solution

Follow our step by step solution on how to calculate Thickness of Aquifer given Drawdown Value measured at Well?

FIRST Step Consider the formula
b=st+hw
Next Step Substitute values of Variables
b=0.83m+2.44m
Next Step Prepare to Evaluate
b=0.83+2.44
LAST Step Evaluate
b=3.27m

Thickness of Aquifer given Drawdown Value measured at Well Formula Elements

Variables
Thickness of Aquifer
The Thickness of Aquifer vertical thickness of the hydro geologically defined aquifer in which the pore spaces of the rock forming the aquifer are filled with water.
Symbol: b
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Total Drawdown
The Total Drawdown is defined as the reduction in hydraulic head observed at a well in an aquifer, typically due to pumping a well as part of an aquifer test or well test.
Symbol: st
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Depth of Water
Depth of Water is the depth in the well measured above the impermeable layer.
Symbol: hw
Measurement: LengthUnit: m
Note: Value should be greater than 0.

Other Formulas to find Thickness of Aquifer

​Go Thickness of Aquifer for Discharge in Unconfined Aquifer with Base 10
b=hw2+Qlog((Rwr),10)1.36Ks

Other formulas in Aquifer Thickness category

​Go Thickness of Aquifer given Discharge in Unconfined Aquifer
H=hw2+Qlog((Rwr),e)πKWH
​Go Cross-section Area of Soil Mass given Flow Velocity
Axsec=(VaqVf)
​Go Length of Strainer given Discharge
lst=(Qlog((Rwr),10)2.72KWHStw)-(Stw2)

How to Evaluate Thickness of Aquifer given Drawdown Value measured at Well?

Thickness of Aquifer given Drawdown Value measured at Well evaluator uses Thickness of Aquifer = Total Drawdown+Depth of Water to evaluate the Thickness of Aquifer, The Thickness of Aquifer given Drawdown Value measured at Well formula is defined as the value of thickness of aquifer when we have prior information of drawdown. Thickness of Aquifer is denoted by b symbol.

How to evaluate Thickness of Aquifer given Drawdown Value measured at Well using this online evaluator? To use this online evaluator for Thickness of Aquifer given Drawdown Value measured at Well, enter Total Drawdown (st) & Depth of Water (hw) and hit the calculate button.

FAQs on Thickness of Aquifer given Drawdown Value measured at Well

What is the formula to find Thickness of Aquifer given Drawdown Value measured at Well?
The formula of Thickness of Aquifer given Drawdown Value measured at Well is expressed as Thickness of Aquifer = Total Drawdown+Depth of Water. Here is an example- 3.27 = 0.83+2.44.
How to calculate Thickness of Aquifer given Drawdown Value measured at Well?
With Total Drawdown (st) & Depth of Water (hw) we can find Thickness of Aquifer given Drawdown Value measured at Well using the formula - Thickness of Aquifer = Total Drawdown+Depth of Water.
What are the other ways to Calculate Thickness of Aquifer?
Here are the different ways to Calculate Thickness of Aquifer-
  • Thickness of Aquifer=sqrt(Depth of Water^2+(Discharge*log((Radius of Influence/Radius of Well),10))/(1.36*Standard Coefficient of Permeability at 20°C))OpenImg
Can the Thickness of Aquifer given Drawdown Value measured at Well be negative?
No, the Thickness of Aquifer given Drawdown Value measured at Well, measured in Length cannot be negative.
Which unit is used to measure Thickness of Aquifer given Drawdown Value measured at Well?
Thickness of Aquifer given Drawdown Value measured at Well is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Thickness of Aquifer given Drawdown Value measured at Well can be measured.
Copied!