Thermal Resistance of SCR Formula

Fx Copy
LaTeX Copy
Thermal resistance of SCR is defined as the the ratio of the temperature difference between the two faces of a material to the rate of heat flow per unit area in a SCR. Check FAQs
θ=Tjunc-TambPdis
θ - Thermal Resistance?Tjunc - Junction Temperature?Tamb - Ambient Temperature?Pdis - Power Dissipated by Heat?

Thermal Resistance of SCR Example

With values
With units
Only example

Here is how the Thermal Resistance of SCR equation looks like with Values.

Here is how the Thermal Resistance of SCR equation looks like with Units.

Here is how the Thermal Resistance of SCR equation looks like.

1.4968Edit=10.2Edit-5.81Edit2.933Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power Electronics » fx Thermal Resistance of SCR

Thermal Resistance of SCR Solution

Follow our step by step solution on how to calculate Thermal Resistance of SCR?

FIRST Step Consider the formula
θ=Tjunc-TambPdis
Next Step Substitute values of Variables
θ=10.2K-5.81K2.933W
Next Step Prepare to Evaluate
θ=10.2-5.812.933
Next Step Evaluate
θ=1.49676099556768K/W
LAST Step Rounding Answer
θ=1.4968K/W

Thermal Resistance of SCR Formula Elements

Variables
Thermal Resistance
Thermal resistance of SCR is defined as the the ratio of the temperature difference between the two faces of a material to the rate of heat flow per unit area in a SCR.
Symbol: θ
Measurement: Thermal ResistanceUnit: K/W
Note: Value can be positive or negative.
Junction Temperature
Junction temperature is defined as the temperature of the junction of a SCR due to movement of charge.
Symbol: Tjunc
Measurement: TemperatureUnit: K
Note: Value should be greater than 0.
Ambient Temperature
Ambient temperature is defined as the temperature of the surroundings of the SCR.
Symbol: Tamb
Measurement: TemperatureUnit: K
Note: Value should be greater than 0.
Power Dissipated by Heat
Power Dissipated by Heat in SCR is defined as the average of the total heat generated at the junctions of the SCR due to movement of charge.
Symbol: Pdis
Measurement: PowerUnit: W
Note: Value should be greater than 0.

Other formulas in SCR Performance Parameters category

​Go Derating Factor of Series Connected Thyristor String
DRF=1-VstringVssn
​Go Leakage Current of Collector-Base Junction
ICBO=IC-αIC
​Go Power Dissipated by Heat in SCR
Pdis=Tjunc-Tambθ
​Go Worst Case Steady State Voltage across First Thyristor in Series Connected Thyristors
Vss=Vstring+Rstb(n-1)ΔIDn

How to Evaluate Thermal Resistance of SCR?

Thermal Resistance of SCR evaluator uses Thermal Resistance = (Junction Temperature-Ambient Temperature)/Power Dissipated by Heat to evaluate the Thermal Resistance, The Thermal resistance of SCR formula is defined as the ratio of the temperature difference between the two faces of a material to the rate of heat flow per unit area in a SCR. Thermal Resistance is denoted by θ symbol.

How to evaluate Thermal Resistance of SCR using this online evaluator? To use this online evaluator for Thermal Resistance of SCR, enter Junction Temperature (Tjunc), Ambient Temperature (Tamb) & Power Dissipated by Heat (Pdis) and hit the calculate button.

FAQs on Thermal Resistance of SCR

What is the formula to find Thermal Resistance of SCR?
The formula of Thermal Resistance of SCR is expressed as Thermal Resistance = (Junction Temperature-Ambient Temperature)/Power Dissipated by Heat. Here is an example- 1.496761 = (10.2-5.81)/2.933.
How to calculate Thermal Resistance of SCR?
With Junction Temperature (Tjunc), Ambient Temperature (Tamb) & Power Dissipated by Heat (Pdis) we can find Thermal Resistance of SCR using the formula - Thermal Resistance = (Junction Temperature-Ambient Temperature)/Power Dissipated by Heat.
Can the Thermal Resistance of SCR be negative?
Yes, the Thermal Resistance of SCR, measured in Thermal Resistance can be negative.
Which unit is used to measure Thermal Resistance of SCR?
Thermal Resistance of SCR is usually measured using the Kelvin per Watt[K/W] for Thermal Resistance. Degree Fahrenheit hour per Btu (IT)[K/W], Degree Fahrenheit Hour per Btu (th)[K/W], Kelvin per Milliwatt[K/W] are the few other units in which Thermal Resistance of SCR can be measured.
Copied!