Fx Copy
LaTeX Copy
The tensile strength of connected part is the maximum stress that a material can bear before breaking when it is allowed to be stretched or pulled. Check FAQs
Fu=Fp0.80
Fu - Tensile Strength of connected part?Fp - Allowable Bearing Stress?

Tensile Strength of Connected Part given Allowable Bearing Stress on Milled Stiffeners Example

With values
With units
Only example

Here is how the Tensile Strength of Connected Part given Allowable Bearing Stress on Milled Stiffeners equation looks like with Values.

Here is how the Tensile Strength of Connected Part given Allowable Bearing Stress on Milled Stiffeners equation looks like with Units.

Here is how the Tensile Strength of Connected Part given Allowable Bearing Stress on Milled Stiffeners equation looks like.

133.75Edit=107Edit0.80
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Bridge and Suspension Cable » fx Tensile Strength of Connected Part given Allowable Bearing Stress on Milled Stiffeners

Tensile Strength of Connected Part given Allowable Bearing Stress on Milled Stiffeners Solution

Follow our step by step solution on how to calculate Tensile Strength of Connected Part given Allowable Bearing Stress on Milled Stiffeners?

FIRST Step Consider the formula
Fu=Fp0.80
Next Step Substitute values of Variables
Fu=107MPa0.80
Next Step Prepare to Evaluate
Fu=1070.80
Next Step Evaluate
Fu=133750000Pa
LAST Step Convert to Output's Unit
Fu=133.75MPa

Tensile Strength of Connected Part given Allowable Bearing Stress on Milled Stiffeners Formula Elements

Variables
Tensile Strength of connected part
The tensile strength of connected part is the maximum stress that a material can bear before breaking when it is allowed to be stretched or pulled.
Symbol: Fu
Measurement: StressUnit: MPa
Note: Value can be positive or negative.
Allowable Bearing Stress
The allowable bearing stress is the maximum bearing stress that can be applied to the structure such that it is safe against instability due to shear failure.
Symbol: Fp
Measurement: StressUnit: MPa
Note: Value can be positive or negative.

Other Formulas to find Tensile Strength of connected part

​Go Tensile Strength of Connected Part given Allowable Bearing Stress for High Strength Bolts
Fu=Fp1.35

Other formulas in Bearing on Milled Surfaces and Bridge Fasteners category

​Go Allowable Stress for Expansion Rollers and Rockers where Diameter is up to 635 mm
p=(fy-1320)0.6d
​Go Allowable Stress for Expansion Rollers and Rockers where Diameter is from 635 mm to 3175 mm
p=(fy-1320)3d
​Go Diameter of Roller or Rocker for d up to 635 mm
d=p(fy20)0.6
​Go Diameter of Roller or Rocker for d from 635 to 3125mm
d=(p(fy-1320)3)2

How to Evaluate Tensile Strength of Connected Part given Allowable Bearing Stress on Milled Stiffeners?

Tensile Strength of Connected Part given Allowable Bearing Stress on Milled Stiffeners evaluator uses Tensile Strength of connected part = Allowable Bearing Stress/0.80 to evaluate the Tensile Strength of connected part, The Tensile Strength of Connected Part given Allowable Bearing Stress on Milled Stiffeners formula is defined as the maximum load in tension that a material which is connected can withstand before breaking or fracturing. Tensile Strength of connected part is denoted by Fu symbol.

How to evaluate Tensile Strength of Connected Part given Allowable Bearing Stress on Milled Stiffeners using this online evaluator? To use this online evaluator for Tensile Strength of Connected Part given Allowable Bearing Stress on Milled Stiffeners, enter Allowable Bearing Stress (Fp) and hit the calculate button.

FAQs on Tensile Strength of Connected Part given Allowable Bearing Stress on Milled Stiffeners

What is the formula to find Tensile Strength of Connected Part given Allowable Bearing Stress on Milled Stiffeners?
The formula of Tensile Strength of Connected Part given Allowable Bearing Stress on Milled Stiffeners is expressed as Tensile Strength of connected part = Allowable Bearing Stress/0.80. Here is an example- 0.000134 = 107000000/0.80.
How to calculate Tensile Strength of Connected Part given Allowable Bearing Stress on Milled Stiffeners?
With Allowable Bearing Stress (Fp) we can find Tensile Strength of Connected Part given Allowable Bearing Stress on Milled Stiffeners using the formula - Tensile Strength of connected part = Allowable Bearing Stress/0.80.
What are the other ways to Calculate Tensile Strength of connected part?
Here are the different ways to Calculate Tensile Strength of connected part-
  • Tensile Strength of connected part=Allowable Bearing Stress/1.35OpenImg
Can the Tensile Strength of Connected Part given Allowable Bearing Stress on Milled Stiffeners be negative?
Yes, the Tensile Strength of Connected Part given Allowable Bearing Stress on Milled Stiffeners, measured in Stress can be negative.
Which unit is used to measure Tensile Strength of Connected Part given Allowable Bearing Stress on Milled Stiffeners?
Tensile Strength of Connected Part given Allowable Bearing Stress on Milled Stiffeners is usually measured using the Megapascal[MPa] for Stress. Pascal[MPa], Newton per Square Meter[MPa], Newton per Square Millimeter[MPa] are the few other units in which Tensile Strength of Connected Part given Allowable Bearing Stress on Milled Stiffeners can be measured.
Copied!