Tensile Resistance of Plate between two Rivets Formula

Fx Copy
LaTeX Copy
Tensile Resistance of Plate Per Rivet Pitch is defined as the maximum load that the riveted plate material can support without fracture when being stretched. Check FAQs
Pt=(p-d)t1σt
Pt - Tensile Resistance of Plate Per Rivet Pitch?p - Pitch of Rivet?d - Diameter of Rivet?t1 - Thickness of Plate 1 of Riveted Joint?σt - Tensile Stress in Riveted Plate?

Tensile Resistance of Plate between two Rivets Example

With values
With units
Only example

Here is how the Tensile Resistance of Plate between two Rivets equation looks like with Values.

Here is how the Tensile Resistance of Plate between two Rivets equation looks like with Units.

Here is how the Tensile Resistance of Plate between two Rivets equation looks like.

28620Edit=(54Edit-18Edit)10.6Edit75Edit
You are here -
HomeIcon Home » Category Physics » Category Mechanical » Category Design of Machine Elements » fx Tensile Resistance of Plate between two Rivets

Tensile Resistance of Plate between two Rivets Solution

Follow our step by step solution on how to calculate Tensile Resistance of Plate between two Rivets?

FIRST Step Consider the formula
Pt=(p-d)t1σt
Next Step Substitute values of Variables
Pt=(54mm-18mm)10.6mm75N/mm²
Next Step Convert Units
Pt=(0.054m-0.018m)0.0106m7.5E+7Pa
Next Step Prepare to Evaluate
Pt=(0.054-0.018)0.01067.5E+7
LAST Step Evaluate
Pt=28620N

Tensile Resistance of Plate between two Rivets Formula Elements

Variables
Tensile Resistance of Plate Per Rivet Pitch
Tensile Resistance of Plate Per Rivet Pitch is defined as the maximum load that the riveted plate material can support without fracture when being stretched.
Symbol: Pt
Measurement: ForceUnit: N
Note: Value should be greater than 0.
Pitch of Rivet
Pitch of Rivet is defined as the distance between the centers of adjacent rivets that hold together the parts of a built member.
Symbol: p
Measurement: LengthUnit: mm
Note: Value should be greater than 0.
Diameter of Rivet
Diameter of Rivet is somewhat equal to diameter of the hole in which rivetting is to be done. It is the diameter of the shank length of a rivet.
Symbol: d
Measurement: LengthUnit: mm
Note: Value should be greater than 0.
Thickness of Plate 1 of Riveted Joint
Thickness of Plate 1 of Riveted Joint is defined as the thickness of the first plate that is joined by the rivet.
Symbol: t1
Measurement: LengthUnit: mm
Note: Value should be greater than 0.
Tensile Stress in Riveted Plate
Tensile Stress in Riveted Plate is the stress developed into the plate joined by the riveted joint due to the tensile load acting onto it.
Symbol: σt
Measurement: PressureUnit: N/mm²
Note: Value should be greater than 0.

Other formulas in Stresses and Resistances category

​Go Permissible Shear Stress for Rivet given Shear Resistance of Rivet Per Pitch Length
τ=ps(π4)d2
​Go Permissible Shear Stress for Rivet for Single Shear
τ=ps(π4)nd2
​Go Permissible Tensile Stress of Plate given Tensile Resistance of Plate between two Rivets
σt=Pt(p-d)t1
​Go Permissible Compressive Stress of Plate Material given Crushing Resistance of Plates
σc=Pcdnt1

How to Evaluate Tensile Resistance of Plate between two Rivets?

Tensile Resistance of Plate between two Rivets evaluator uses Tensile Resistance of Plate Per Rivet Pitch = (Pitch of Rivet-Diameter of Rivet)*Thickness of Plate 1 of Riveted Joint*Tensile Stress in Riveted Plate to evaluate the Tensile Resistance of Plate Per Rivet Pitch, The Tensile Resistance of Plate between two Rivets formula is defined as maximum load that a material can support without fracture when being stretched, divided by the original cross-sectional area of the material. Tensile Resistance of Plate Per Rivet Pitch is denoted by Pt symbol.

How to evaluate Tensile Resistance of Plate between two Rivets using this online evaluator? To use this online evaluator for Tensile Resistance of Plate between two Rivets, enter Pitch of Rivet (p), Diameter of Rivet (d), Thickness of Plate 1 of Riveted Joint (t1) & Tensile Stress in Riveted Plate t) and hit the calculate button.

FAQs on Tensile Resistance of Plate between two Rivets

What is the formula to find Tensile Resistance of Plate between two Rivets?
The formula of Tensile Resistance of Plate between two Rivets is expressed as Tensile Resistance of Plate Per Rivet Pitch = (Pitch of Rivet-Diameter of Rivet)*Thickness of Plate 1 of Riveted Joint*Tensile Stress in Riveted Plate. Here is an example- 28620 = (0.054-0.018)*0.0106*75000000.
How to calculate Tensile Resistance of Plate between two Rivets?
With Pitch of Rivet (p), Diameter of Rivet (d), Thickness of Plate 1 of Riveted Joint (t1) & Tensile Stress in Riveted Plate t) we can find Tensile Resistance of Plate between two Rivets using the formula - Tensile Resistance of Plate Per Rivet Pitch = (Pitch of Rivet-Diameter of Rivet)*Thickness of Plate 1 of Riveted Joint*Tensile Stress in Riveted Plate.
Can the Tensile Resistance of Plate between two Rivets be negative?
No, the Tensile Resistance of Plate between two Rivets, measured in Force cannot be negative.
Which unit is used to measure Tensile Resistance of Plate between two Rivets?
Tensile Resistance of Plate between two Rivets is usually measured using the Newton[N] for Force. Exanewton[N], Meganewton[N], Kilonewton[N] are the few other units in which Tensile Resistance of Plate between two Rivets can be measured.
Copied!