Fx Copy
LaTeX Copy
Temperature in Aeration Tank is the temperature required in aeration tank during the various treatment process in Kelvin. Check FAQs
Ta=log((N9.17Ns(DS-DL)0.85),1.024)+20
Ta - Temperature in Aeration Tank?N - Oxygen Transferred?Ns - Oxygen Transfer Capacity?DS - Dissolved Oxygen Saturation?DL - Operation Dissolved Oxygen?

Temperature when Correction Factor is 0.85 Example

With values
With units
Only example

Here is how the Temperature when Correction Factor is 0.85 equation looks like with Values.

Here is how the Temperature when Correction Factor is 0.85 equation looks like with Units.

Here is how the Temperature when Correction Factor is 0.85 equation looks like.

20.0235Edit=log((3Edit9.172.03Edit(5803Edit-2.01Edit)0.85),1.024)+20
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Temperature when Correction Factor is 0.85

Temperature when Correction Factor is 0.85 Solution

Follow our step by step solution on how to calculate Temperature when Correction Factor is 0.85?

FIRST Step Consider the formula
Ta=log((N9.17Ns(DS-DL)0.85),1.024)+20
Next Step Substitute values of Variables
Ta=log((3kg/h/kW9.172.03kg/h/kW(5803mg/L-2.01mg/L)0.85),1.024)+20
Next Step Convert Units
Ta=log((8.3E-7kg/s/W9.175.6E-7kg/s/W(5.803kg/m³-0.002kg/m³)0.85),1.024)+20
Next Step Prepare to Evaluate
Ta=log((8.3E-79.175.6E-7(5.803-0.002)0.85),1.024)+20
Next Step Evaluate
Ta=20.0234583877333K
LAST Step Rounding Answer
Ta=20.0235K

Temperature when Correction Factor is 0.85 Formula Elements

Variables
Functions
Temperature in Aeration Tank
Temperature in Aeration Tank is the temperature required in aeration tank during the various treatment process in Kelvin.
Symbol: Ta
Measurement: TemperatureUnit: K
Note: Value should be greater than 0.
Oxygen Transferred
Oxygen Transferred is the amount of oxygen that is moved from the air into the water.
Symbol: N
Measurement: Specific Fuel ConsumptionUnit: kg/h/kW
Note: Value should be greater than 0.
Oxygen Transfer Capacity
Oxygen Transfer Capacity is the ability of a system, typically in a wastewater treatment context, to transfer oxygen from the air into the water.
Symbol: Ns
Measurement: Specific Fuel ConsumptionUnit: kg/h/kW
Note: Value should be greater than 0.
Dissolved Oxygen Saturation
Dissolved Oxygen Saturation is the maximum amount of oxygen that can be dissolved in water at a given temperature and pressure.
Symbol: DS
Measurement: DensityUnit: mg/L
Note: Value should be greater than 0.
Operation Dissolved Oxygen
Operation Dissolved Oxygen is the amount of oxygen that is present in water. It is a crucial parameter in assessing water quality because it is essential for the survival of aquatic organisms.
Symbol: DL
Measurement: DensityUnit: mg/L
Note: Value should be greater than 0.
log
Logarithmic function is an inverse function to exponentiation.
Syntax: log(Base, Number)

Other Formulas to find Temperature in Aeration Tank

​Go Temperature given Oxygen Transfer Capacity
Ta=log((N9.17Ns(DS-DL)Cf),1.024)+20
​Go Temperature given Difference between Saturation D.O and Operation D.O
Ta=log((N9.17NsDCf),1.024)+20
​Go Temperature when Correction Factor is 0.8
Ta=log((N9.17Ns(DS-DL)0.8),1.024)+20

How to Evaluate Temperature when Correction Factor is 0.85?

Temperature when Correction Factor is 0.85 evaluator uses Temperature in Aeration Tank = log(((Oxygen Transferred*9.17)/(Oxygen Transfer Capacity*(Dissolved Oxygen Saturation-Operation Dissolved Oxygen)*0.85)),1.024)+20 to evaluate the Temperature in Aeration Tank, The Temperature when Correction Factor is 0.85 formula is defined as the calculation of the value of temperature when correction factor is 0.85. Temperature in Aeration Tank is denoted by Ta symbol.

How to evaluate Temperature when Correction Factor is 0.85 using this online evaluator? To use this online evaluator for Temperature when Correction Factor is 0.85, enter Oxygen Transferred (N), Oxygen Transfer Capacity (Ns), Dissolved Oxygen Saturation (DS) & Operation Dissolved Oxygen (DL) and hit the calculate button.

FAQs on Temperature when Correction Factor is 0.85

What is the formula to find Temperature when Correction Factor is 0.85?
The formula of Temperature when Correction Factor is 0.85 is expressed as Temperature in Aeration Tank = log(((Oxygen Transferred*9.17)/(Oxygen Transfer Capacity*(Dissolved Oxygen Saturation-Operation Dissolved Oxygen)*0.85)),1.024)+20. Here is an example- 20.02346 = log(((8.33333333333333E-07*9.17)/(5.63888888888889E-07*(5.803-0.00201)*0.85)),1.024)+20.
How to calculate Temperature when Correction Factor is 0.85?
With Oxygen Transferred (N), Oxygen Transfer Capacity (Ns), Dissolved Oxygen Saturation (DS) & Operation Dissolved Oxygen (DL) we can find Temperature when Correction Factor is 0.85 using the formula - Temperature in Aeration Tank = log(((Oxygen Transferred*9.17)/(Oxygen Transfer Capacity*(Dissolved Oxygen Saturation-Operation Dissolved Oxygen)*0.85)),1.024)+20. This formula also uses Logarithmic Inverse (log) function(s).
What are the other ways to Calculate Temperature in Aeration Tank?
Here are the different ways to Calculate Temperature in Aeration Tank-
  • Temperature in Aeration Tank=log(((Oxygen Transferred*9.17)/(Oxygen Transfer Capacity*(Dissolved Oxygen Saturation-Operation Dissolved Oxygen)*Correction Factor)),1.024)+20OpenImg
  • Temperature in Aeration Tank=log(((Oxygen Transferred*9.17)/(Oxygen Transfer Capacity*Difference between Saturation DO and Operation DO*Correction Factor)),1.024)+20OpenImg
  • Temperature in Aeration Tank=log(((Oxygen Transferred*9.17)/(Oxygen Transfer Capacity*(Dissolved Oxygen Saturation-Operation Dissolved Oxygen)*0.8)),1.024)+20OpenImg
Can the Temperature when Correction Factor is 0.85 be negative?
No, the Temperature when Correction Factor is 0.85, measured in Temperature cannot be negative.
Which unit is used to measure Temperature when Correction Factor is 0.85?
Temperature when Correction Factor is 0.85 is usually measured using the Kelvin[K] for Temperature. Celsius[K], Fahrenheit[K], Rankine[K] are the few other units in which Temperature when Correction Factor is 0.85 can be measured.
Copied!