Temperature given Reoxygenation Coefficient at T degree Celsius Formula

Fx Copy
LaTeX Copy
Temperature is the degree or intensity of heat present in a substance or object. Check FAQs
T=log((KRKR(20)),1.016)+20
T - Temperature?KR - Reoxygenation Coefficient?KR(20) - Reoxygenation Coefficient at Temperature 20?

Temperature given Reoxygenation Coefficient at T degree Celsius Example

With values
With units
Only example

Here is how the Temperature given Reoxygenation Coefficient at T degree Celsius equation looks like with Values.

Here is how the Temperature given Reoxygenation Coefficient at T degree Celsius equation looks like with Units.

Here is how the Temperature given Reoxygenation Coefficient at T degree Celsius equation looks like.

19.9853Edit=log((0.22Edit0.65Edit),1.016)+20
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Temperature given Reoxygenation Coefficient at T degree Celsius

Temperature given Reoxygenation Coefficient at T degree Celsius Solution

Follow our step by step solution on how to calculate Temperature given Reoxygenation Coefficient at T degree Celsius?

FIRST Step Consider the formula
T=log((KRKR(20)),1.016)+20
Next Step Substitute values of Variables
T=log((0.22d⁻¹0.65d⁻¹),1.016)+20
Next Step Convert Units
T=log((2.5E-6s⁻¹7.5E-6s⁻¹),1.016)+20
Next Step Prepare to Evaluate
T=log((2.5E-67.5E-6),1.016)+20
Next Step Evaluate
T=19.9853478330131K
LAST Step Rounding Answer
T=19.9853K

Temperature given Reoxygenation Coefficient at T degree Celsius Formula Elements

Variables
Functions
Temperature
Temperature is the degree or intensity of heat present in a substance or object.
Symbol: T
Measurement: TemperatureUnit: K
Note: Value can be positive or negative.
Reoxygenation Coefficient
Reoxygenation Coefficient is referred as the parameter used in water quality modeling to describe the rate at which oxygen is transferred from the atmosphere to the water body.
Symbol: KR
Measurement: First Order Reaction Rate ConstantUnit: d⁻¹
Note: Value should be greater than 0.
Reoxygenation Coefficient at Temperature 20
Reoxygenation Coefficient at Temperature 20 is the BOD rate constant at 20°C temperature.
Symbol: KR(20)
Measurement: First Order Reaction Rate ConstantUnit: d⁻¹
Note: Value should be greater than 0.
log
Logarithmic function is an inverse function to exponentiation.
Syntax: log(Base, Number)

Other formulas in Reoxygenation Coefficient category

​Go Reoxygenation Coefficients
KR=KR(20)(1.016)T-20
​Go Reoxygenation Coefficient at 20 Degree Celsius
KR(20)=KR(1.016)T-20
​Go Reoxygenation Coefficient given Self Purification Constant
KR=KDf
​Go Reoxygenation Coefficient given Critical Oxygen Deficit
KR=KDLt10-KDtcDc

How to Evaluate Temperature given Reoxygenation Coefficient at T degree Celsius?

Temperature given Reoxygenation Coefficient at T degree Celsius evaluator uses Temperature = log((Reoxygenation Coefficient/Reoxygenation Coefficient at Temperature 20),1.016)+20 to evaluate the Temperature, The Temperature given Reoxygenation Coefficient at T degree Celsius formula is the defined as the temperature at which oxygen is added to the water body. It is expressed in °C. Temperature is denoted by T symbol.

How to evaluate Temperature given Reoxygenation Coefficient at T degree Celsius using this online evaluator? To use this online evaluator for Temperature given Reoxygenation Coefficient at T degree Celsius, enter Reoxygenation Coefficient (KR) & Reoxygenation Coefficient at Temperature 20 (KR(20)) and hit the calculate button.

FAQs on Temperature given Reoxygenation Coefficient at T degree Celsius

What is the formula to find Temperature given Reoxygenation Coefficient at T degree Celsius?
The formula of Temperature given Reoxygenation Coefficient at T degree Celsius is expressed as Temperature = log((Reoxygenation Coefficient/Reoxygenation Coefficient at Temperature 20),1.016)+20. Here is an example- 19.98653 = log((2.5462962962963E-06/7.52314814814815E-06),1.016)+20.
How to calculate Temperature given Reoxygenation Coefficient at T degree Celsius?
With Reoxygenation Coefficient (KR) & Reoxygenation Coefficient at Temperature 20 (KR(20)) we can find Temperature given Reoxygenation Coefficient at T degree Celsius using the formula - Temperature = log((Reoxygenation Coefficient/Reoxygenation Coefficient at Temperature 20),1.016)+20. This formula also uses Logarithmic Inverse (log) function(s).
Can the Temperature given Reoxygenation Coefficient at T degree Celsius be negative?
Yes, the Temperature given Reoxygenation Coefficient at T degree Celsius, measured in Temperature can be negative.
Which unit is used to measure Temperature given Reoxygenation Coefficient at T degree Celsius?
Temperature given Reoxygenation Coefficient at T degree Celsius is usually measured using the Kelvin[K] for Temperature. Celsius[K], Fahrenheit[K], Rankine[K] are the few other units in which Temperature given Reoxygenation Coefficient at T degree Celsius can be measured.
Copied!