Temperature in Aeration Tank is the temperature required in aeration tank during the various treatment process in Kelvin. Check FAQs
Ta=log((N9.17NsDCf),1.024)+20
Ta - Temperature in Aeration Tank?N - Oxygen Transferred?Ns - Oxygen Transfer Capacity?D - Difference between Saturation DO and Operation DO?Cf - Correction Factor?

Temperature given Difference between Saturation D.O and Operation D.O Example

With values
With units
Only example

Here is how the Temperature given Difference between Saturation D.O and Operation D.O equation looks like with Values.

Here is how the Temperature given Difference between Saturation D.O and Operation D.O equation looks like with Units.

Here is how the Temperature given Difference between Saturation D.O and Operation D.O equation looks like.

20.0168Edit=log((3Edit9.172.03Edit6600Edit0.5Edit),1.024)+20
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Temperature given Difference between Saturation D.O and Operation D.O

Temperature given Difference between Saturation D.O and Operation D.O Solution

Follow our step by step solution on how to calculate Temperature given Difference between Saturation D.O and Operation D.O?

FIRST Step Consider the formula
Ta=log((N9.17NsDCf),1.024)+20
Next Step Substitute values of Variables
Ta=log((3kg/h/kW9.172.03kg/h/kW6600mg/L0.5),1.024)+20
Next Step Convert Units
Ta=log((8.3E-7kg/s/W9.175.6E-7kg/s/W6.6kg/m³0.5),1.024)+20
Next Step Prepare to Evaluate
Ta=log((8.3E-79.175.6E-76.60.5),1.024)+20
Next Step Evaluate
Ta=20.0167893759449K
LAST Step Rounding Answer
Ta=20.0168K

Temperature given Difference between Saturation D.O and Operation D.O Formula Elements

Variables
Functions
Temperature in Aeration Tank
Temperature in Aeration Tank is the temperature required in aeration tank during the various treatment process in Kelvin.
Symbol: Ta
Measurement: TemperatureUnit: K
Note: Value should be greater than 0.
Oxygen Transferred
Oxygen Transferred is the amount of oxygen that is moved from the air into the water.
Symbol: N
Measurement: Specific Fuel ConsumptionUnit: kg/h/kW
Note: Value should be greater than 0.
Oxygen Transfer Capacity
Oxygen Transfer Capacity is the ability of a system, typically in a wastewater treatment context, to transfer oxygen from the air into the water.
Symbol: Ns
Measurement: Specific Fuel ConsumptionUnit: kg/h/kW
Note: Value should be greater than 0.
Difference between Saturation DO and Operation DO
Difference between Saturation DO and Operation DO is the value obtained after subtracting operation DO from saturation DO.
Symbol: D
Measurement: DensityUnit: mg/L
Note: Value should be greater than 0.
Correction Factor
Correction Factor is that which is multiplied with the result of an equation to correct for a known amount of systematic error.
Symbol: Cf
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
log
Logarithmic function is an inverse function to exponentiation.
Syntax: log(Base, Number)

Other Formulas to find Temperature in Aeration Tank

​Go Temperature given Oxygen Transfer Capacity
Ta=log((N9.17Ns(DS-DL)Cf),1.024)+20
​Go Temperature when Correction Factor is 0.8
Ta=log((N9.17Ns(DS-DL)0.8),1.024)+20
​Go Temperature when Correction Factor is 0.85
Ta=log((N9.17Ns(DS-DL)0.85),1.024)+20

How to Evaluate Temperature given Difference between Saturation D.O and Operation D.O?

Temperature given Difference between Saturation D.O and Operation D.O evaluator uses Temperature in Aeration Tank = log(((Oxygen Transferred*9.17)/(Oxygen Transfer Capacity*Difference between Saturation DO and Operation DO*Correction Factor)),1.024)+20 to evaluate the Temperature in Aeration Tank, The Temperature given Difference between Saturation D.O and Operation D.O formula is defined as the calculation of value of temperature when we have prior information of difference between saturation DO and operation DO. Temperature in Aeration Tank is denoted by Ta symbol.

How to evaluate Temperature given Difference between Saturation D.O and Operation D.O using this online evaluator? To use this online evaluator for Temperature given Difference between Saturation D.O and Operation D.O, enter Oxygen Transferred (N), Oxygen Transfer Capacity (Ns), Difference between Saturation DO and Operation DO (D) & Correction Factor (Cf) and hit the calculate button.

FAQs on Temperature given Difference between Saturation D.O and Operation D.O

What is the formula to find Temperature given Difference between Saturation D.O and Operation D.O?
The formula of Temperature given Difference between Saturation D.O and Operation D.O is expressed as Temperature in Aeration Tank = log(((Oxygen Transferred*9.17)/(Oxygen Transfer Capacity*Difference between Saturation DO and Operation DO*Correction Factor)),1.024)+20. Here is an example- 20.01679 = log(((8.33333333333333E-07*9.17)/(5.63888888888889E-07*6.6*0.5)),1.024)+20.
How to calculate Temperature given Difference between Saturation D.O and Operation D.O?
With Oxygen Transferred (N), Oxygen Transfer Capacity (Ns), Difference between Saturation DO and Operation DO (D) & Correction Factor (Cf) we can find Temperature given Difference between Saturation D.O and Operation D.O using the formula - Temperature in Aeration Tank = log(((Oxygen Transferred*9.17)/(Oxygen Transfer Capacity*Difference between Saturation DO and Operation DO*Correction Factor)),1.024)+20. This formula also uses Logarithmic Inverse Function function(s).
What are the other ways to Calculate Temperature in Aeration Tank?
Here are the different ways to Calculate Temperature in Aeration Tank-
  • Temperature in Aeration Tank=log(((Oxygen Transferred*9.17)/(Oxygen Transfer Capacity*(Dissolved Oxygen Saturation-Operation Dissolved Oxygen)*Correction Factor)),1.024)+20OpenImg
  • Temperature in Aeration Tank=log(((Oxygen Transferred*9.17)/(Oxygen Transfer Capacity*(Dissolved Oxygen Saturation-Operation Dissolved Oxygen)*0.8)),1.024)+20OpenImg
  • Temperature in Aeration Tank=log(((Oxygen Transferred*9.17)/(Oxygen Transfer Capacity*(Dissolved Oxygen Saturation-Operation Dissolved Oxygen)*0.85)),1.024)+20OpenImg
Can the Temperature given Difference between Saturation D.O and Operation D.O be negative?
No, the Temperature given Difference between Saturation D.O and Operation D.O, measured in Temperature cannot be negative.
Which unit is used to measure Temperature given Difference between Saturation D.O and Operation D.O?
Temperature given Difference between Saturation D.O and Operation D.O is usually measured using the Kelvin[K] for Temperature. Celsius[K], Fahrenheit[K], Rankine[K] are the few other units in which Temperature given Difference between Saturation D.O and Operation D.O can be measured.