Temperature Corrections for Incorrect Tape Length Formula

Fx Copy
LaTeX Copy
Temperature Corrections for Incorrect Tape Length is the adjustments made to account for the changes in tape length due to temperature variations. Check FAQs
Ctemp=(La-Ao)UlAo
Ctemp - Temperature Corrections for Incorrect Tape Length?La - Actual Tape Length?Ao - Nominal Tape Length?Ul - Unsupported Length?

Temperature Corrections for Incorrect Tape Length Example

With values
With units
Only example

Here is how the Temperature Corrections for Incorrect Tape Length equation looks like with Values.

Here is how the Temperature Corrections for Incorrect Tape Length equation looks like with Units.

Here is how the Temperature Corrections for Incorrect Tape Length equation looks like.

18.5Edit=(5.5Edit-1.8Edit)9Edit1.8Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Surveying Formulas » fx Temperature Corrections for Incorrect Tape Length

Temperature Corrections for Incorrect Tape Length Solution

Follow our step by step solution on how to calculate Temperature Corrections for Incorrect Tape Length?

FIRST Step Consider the formula
Ctemp=(La-Ao)UlAo
Next Step Substitute values of Variables
Ctemp=(5.5m-1.8m)9m1.8m
Next Step Prepare to Evaluate
Ctemp=(5.5-1.8)91.8
LAST Step Evaluate
Ctemp=18.5m

Temperature Corrections for Incorrect Tape Length Formula Elements

Variables
Temperature Corrections for Incorrect Tape Length
Temperature Corrections for Incorrect Tape Length is the adjustments made to account for the changes in tape length due to temperature variations.
Symbol: Ctemp
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Actual Tape Length
Actual Tape Length is the precise length of a measuring tape used in surveying, accounting for any errors or corrections necessary due to temperature, tension, or manufacturing imperfections.
Symbol: La
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Nominal Tape Length
Nominal Tape Length is the length of tape that can be affected by physical imperfections, stretching, or wear.
Symbol: Ao
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Unsupported Length
Unsupported Length is the span or distance between supports or points of restraint for a structural member, such as a beam or a column.
Symbol: Ul
Measurement: LengthUnit: m
Note: Value can be positive or negative.

Other formulas in Temperature Corrections category

​Go Sag Correction between Points of Support
Cs=-(W2)Ul324P2
​Go Tape Weight per Foot for Sag Correction between Points of Support
W=Cs24P2Ul3
​Go Unsupported Tape Length given Sag Correction between Points of Support
Ul=(24CsP2W2)13
​Go Pull-on Tape given Sag Correction between Points of Support
P=-W2Ul324Cs

How to Evaluate Temperature Corrections for Incorrect Tape Length?

Temperature Corrections for Incorrect Tape Length evaluator uses Temperature Corrections for Incorrect Tape Length = ((Actual Tape Length-Nominal Tape Length)*Unsupported Length)/(Nominal Tape Length) to evaluate the Temperature Corrections for Incorrect Tape Length, The Temperature Corrections for Incorrect Tape Length formula is defined as the correction which is applied to correct the length of the tape. Temperature Corrections for Incorrect Tape Length is denoted by Ctemp symbol.

How to evaluate Temperature Corrections for Incorrect Tape Length using this online evaluator? To use this online evaluator for Temperature Corrections for Incorrect Tape Length, enter Actual Tape Length (La), Nominal Tape Length (Ao) & Unsupported Length (Ul) and hit the calculate button.

FAQs on Temperature Corrections for Incorrect Tape Length

What is the formula to find Temperature Corrections for Incorrect Tape Length?
The formula of Temperature Corrections for Incorrect Tape Length is expressed as Temperature Corrections for Incorrect Tape Length = ((Actual Tape Length-Nominal Tape Length)*Unsupported Length)/(Nominal Tape Length). Here is an example- 18.5 = ((5.5-1.8)*9)/(1.8).
How to calculate Temperature Corrections for Incorrect Tape Length?
With Actual Tape Length (La), Nominal Tape Length (Ao) & Unsupported Length (Ul) we can find Temperature Corrections for Incorrect Tape Length using the formula - Temperature Corrections for Incorrect Tape Length = ((Actual Tape Length-Nominal Tape Length)*Unsupported Length)/(Nominal Tape Length).
Can the Temperature Corrections for Incorrect Tape Length be negative?
No, the Temperature Corrections for Incorrect Tape Length, measured in Length cannot be negative.
Which unit is used to measure Temperature Corrections for Incorrect Tape Length?
Temperature Corrections for Incorrect Tape Length is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Temperature Corrections for Incorrect Tape Length can be measured.
Copied!