Suction Temperature at Low Pressure Compressor is the temperature of the refrigerant at the inlet or during the suction stroke. Check FAQs
T1=(T2q)-T2+T3q
T1 - Suction Temperature at Low Pressure Compressor?T2 - Suction Temperature at High Pressure Compressor?q - Cooling Ratio?T3 - Discharge Temperature at High Pressure Compressor?

Suction Temperature at Low Pressure Compressor given Cooling Ratio Example

With values
With units
Only example

Here is how the Suction Temperature at Low Pressure Compressor given Cooling Ratio equation looks like with Values.

Here is how the Suction Temperature at Low Pressure Compressor given Cooling Ratio equation looks like with Units.

Here is how the Suction Temperature at Low Pressure Compressor given Cooling Ratio equation looks like.

300Edit=(400Edit0.9Edit)-400Edit+310Edit0.9Edit
You are here -
HomeIcon Home » Category Physics » Category Mechanical » Category Refrigeration and Air Conditioning » fx Suction Temperature at Low Pressure Compressor given Cooling Ratio

Suction Temperature at Low Pressure Compressor given Cooling Ratio Solution

Follow our step by step solution on how to calculate Suction Temperature at Low Pressure Compressor given Cooling Ratio?

FIRST Step Consider the formula
T1=(T2q)-T2+T3q
Next Step Substitute values of Variables
T1=(400K0.9)-400K+310K0.9
Next Step Prepare to Evaluate
T1=(4000.9)-400+3100.9
LAST Step Evaluate
T1=300K

Suction Temperature at Low Pressure Compressor given Cooling Ratio Formula Elements

Variables
Suction Temperature at Low Pressure Compressor
Suction Temperature at Low Pressure Compressor is the temperature of the refrigerant at the inlet or during the suction stroke.
Symbol: T1
Measurement: TemperatureUnit: K
Note: Value can be positive or negative.
Suction Temperature at High Pressure Compressor
The Suction Temperature at High Pressure Compressor is the temperature of the refrigerant at the inlet or temperature of the refrigerant leaving the intercooler.
Symbol: T2
Measurement: TemperatureUnit: K
Note: Value can be positive or negative.
Cooling Ratio
Cooling Ratio is defined as the ratio of heat abstracted by the cooling system to the heat abstracted to bring the refrigerant to the initial temperature.
Symbol: q
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Discharge Temperature at High Pressure Compressor
Discharge Temperature at High Pressure Compressor is the temperature at which refrigerant leaves the compressor.
Symbol: T3
Measurement: TemperatureUnit: K
Note: Value can be positive or negative.

Other Formulas to find Suction Temperature at Low Pressure Compressor

​Go Suction Temperature at Low pressure compressor when Cooling ratio is constant
T1=T3q+(1-q)(P2P1)nc-1nc

Other formulas in Minimum Work category

​Go Minimum Work required when Temperature at end of Cooling in Intercooler is fixed
W=2(ncnc-1)m[R]T1((P3P1)nc-12nc-1)
​Go Minimum Work required when Cooling Ratio is fixed
W=(ncnc-1)m[R]((T1(P3P1)nc-12nc+Td(P3P1)nc-12nc-T1-T3))
​Go Cooling ratio
q=T2-T3T2-T1
​Go Minimum Work required when Cooling Ratio is fixed and Intercooling is Perfect
W=2(ncnc-1)m[R]Tr((P3P1)nc-12nc-1)

How to Evaluate Suction Temperature at Low Pressure Compressor given Cooling Ratio?

Suction Temperature at Low Pressure Compressor given Cooling Ratio evaluator uses Suction Temperature at Low Pressure Compressor = ((Suction Temperature at High Pressure Compressor*Cooling Ratio)-Suction Temperature at High Pressure Compressor+Discharge Temperature at High Pressure Compressor)/Cooling Ratio to evaluate the Suction Temperature at Low Pressure Compressor, Suction Temperature at Low Pressure Compressor given Cooling Ratio formula is defined as a measure of the temperature at the suction side of a low-pressure compressor, which is critical in determining the performance and efficiency of the compressor in a refrigeration system, particularly in air conditioning and refrigeration applications. Suction Temperature at Low Pressure Compressor is denoted by T1 symbol.

How to evaluate Suction Temperature at Low Pressure Compressor given Cooling Ratio using this online evaluator? To use this online evaluator for Suction Temperature at Low Pressure Compressor given Cooling Ratio, enter Suction Temperature at High Pressure Compressor (T2), Cooling Ratio (q) & Discharge Temperature at High Pressure Compressor (T3) and hit the calculate button.

FAQs on Suction Temperature at Low Pressure Compressor given Cooling Ratio

What is the formula to find Suction Temperature at Low Pressure Compressor given Cooling Ratio?
The formula of Suction Temperature at Low Pressure Compressor given Cooling Ratio is expressed as Suction Temperature at Low Pressure Compressor = ((Suction Temperature at High Pressure Compressor*Cooling Ratio)-Suction Temperature at High Pressure Compressor+Discharge Temperature at High Pressure Compressor)/Cooling Ratio. Here is an example- 300 = ((400*0.9)-400+310)/0.9.
How to calculate Suction Temperature at Low Pressure Compressor given Cooling Ratio?
With Suction Temperature at High Pressure Compressor (T2), Cooling Ratio (q) & Discharge Temperature at High Pressure Compressor (T3) we can find Suction Temperature at Low Pressure Compressor given Cooling Ratio using the formula - Suction Temperature at Low Pressure Compressor = ((Suction Temperature at High Pressure Compressor*Cooling Ratio)-Suction Temperature at High Pressure Compressor+Discharge Temperature at High Pressure Compressor)/Cooling Ratio.
What are the other ways to Calculate Suction Temperature at Low Pressure Compressor?
Here are the different ways to Calculate Suction Temperature at Low Pressure Compressor-
  • Suction Temperature at Low Pressure Compressor=Discharge Temperature at High Pressure Compressor/(Cooling Ratio+(1-Cooling Ratio)*(Discharge Pressure of Low Pressure Compressor/Suction Pressure of Low Pressure Compressor)^((Polytropic Index For Compression-1)/Polytropic Index For Compression))OpenImg
Can the Suction Temperature at Low Pressure Compressor given Cooling Ratio be negative?
Yes, the Suction Temperature at Low Pressure Compressor given Cooling Ratio, measured in Temperature can be negative.
Which unit is used to measure Suction Temperature at Low Pressure Compressor given Cooling Ratio?
Suction Temperature at Low Pressure Compressor given Cooling Ratio is usually measured using the Kelvin[K] for Temperature. Celsius[K], Fahrenheit[K], Rankine[K] are the few other units in which Suction Temperature at Low Pressure Compressor given Cooling Ratio can be measured.
Copied!