Stripping Section Flowrate of Liquid for given Quality of Feed Formula

Fx Copy
LaTeX Copy
Liquid Flowrate in Stripping Section refers to the molar flowrate of liquid traveling through the stripping section of a distillation column. Check FAQs
Lm=Ln+q(F)
Lm - Liquid Flowrate in Stripping Section?Ln - Liquid Flowrate in Rectifying Section?q - Feed Quality?F - Feed Flowrate?

Stripping Section Flowrate of Liquid for given Quality of Feed Example

With values
With units
Only example

Here is how the Stripping Section Flowrate of Liquid for given Quality of Feed equation looks like with Values.

Here is how the Stripping Section Flowrate of Liquid for given Quality of Feed equation looks like with Units.

Here is how the Stripping Section Flowrate of Liquid for given Quality of Feed equation looks like.

593.3399Edit=301.4321Edit+1.345Edit(217.0318Edit)
You are here -
HomeIcon Home » Category Engineering » Category Chemical Engineering » Category Process Equipment Design » fx Stripping Section Flowrate of Liquid for given Quality of Feed

Stripping Section Flowrate of Liquid for given Quality of Feed Solution

Follow our step by step solution on how to calculate Stripping Section Flowrate of Liquid for given Quality of Feed?

FIRST Step Consider the formula
Lm=Ln+q(F)
Next Step Substitute values of Variables
Lm=301.4321mol/s+1.345(217.0318mol/s)
Next Step Prepare to Evaluate
Lm=301.4321+1.345(217.0318)
Next Step Evaluate
Lm=593.339871mol/s
LAST Step Rounding Answer
Lm=593.3399mol/s

Stripping Section Flowrate of Liquid for given Quality of Feed Formula Elements

Variables
Liquid Flowrate in Stripping Section
Liquid Flowrate in Stripping Section refers to the molar flowrate of liquid traveling through the stripping section of a distillation column.
Symbol: Lm
Measurement: Molar Flow RateUnit: mol/s
Note: Value should be greater than 0.
Liquid Flowrate in Rectifying Section
Liquid Flowrate in Rectifying Section refers to the molar flowrate of the liquid component traveling in the rectifying section of distillation column.
Symbol: Ln
Measurement: Molar Flow RateUnit: mol/s
Note: Value should be greater than 0.
Feed Quality
Feed Quality refers to the composition, properties, and condition of the feedstock entering the distillation column.
Symbol: q
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Feed Flowrate
Feed Flowrate is defined as the molar flowrate of the feedstock that is sent into a distillation column.
Symbol: F
Measurement: Molar Flow RateUnit: mol/s
Note: Value should be greater than 0.

Other formulas in Distillation Tower Design category

​Go Clearance Area under Downcomer given Weir Length and Apron Height
Aap=haplw
​Go Active Area given Gas Volumetric Flow and Flow Velocity
Aa=Gvfduf
​Go Column Diameter Based on Vapor Flowrate and Mass Velocity of Vapor
Dc=(4VWπWmax)12
​Go Column Diameter given Maximum Vapor Rate and Maximum Vapor Velocity
Dc=4VWπρVUv

How to Evaluate Stripping Section Flowrate of Liquid for given Quality of Feed?

Stripping Section Flowrate of Liquid for given Quality of Feed evaluator uses Liquid Flowrate in Stripping Section = Liquid Flowrate in Rectifying Section+Feed Quality*(Feed Flowrate) to evaluate the Liquid Flowrate in Stripping Section, The Stripping Section Flowrate of Liquid for given Quality of Feed formula is defined as molar flowrate of the liquid component that travels across the stripping section of a distillation column. Liquid Flowrate in Stripping Section is denoted by Lm symbol.

How to evaluate Stripping Section Flowrate of Liquid for given Quality of Feed using this online evaluator? To use this online evaluator for Stripping Section Flowrate of Liquid for given Quality of Feed, enter Liquid Flowrate in Rectifying Section (Ln), Feed Quality (q) & Feed Flowrate (F) and hit the calculate button.

FAQs on Stripping Section Flowrate of Liquid for given Quality of Feed

What is the formula to find Stripping Section Flowrate of Liquid for given Quality of Feed?
The formula of Stripping Section Flowrate of Liquid for given Quality of Feed is expressed as Liquid Flowrate in Stripping Section = Liquid Flowrate in Rectifying Section+Feed Quality*(Feed Flowrate). Here is an example- 593.3399 = 301.4321+1.345*(217.0318).
How to calculate Stripping Section Flowrate of Liquid for given Quality of Feed?
With Liquid Flowrate in Rectifying Section (Ln), Feed Quality (q) & Feed Flowrate (F) we can find Stripping Section Flowrate of Liquid for given Quality of Feed using the formula - Liquid Flowrate in Stripping Section = Liquid Flowrate in Rectifying Section+Feed Quality*(Feed Flowrate).
Can the Stripping Section Flowrate of Liquid for given Quality of Feed be negative?
No, the Stripping Section Flowrate of Liquid for given Quality of Feed, measured in Molar Flow Rate cannot be negative.
Which unit is used to measure Stripping Section Flowrate of Liquid for given Quality of Feed?
Stripping Section Flowrate of Liquid for given Quality of Feed is usually measured using the Mole per Second[mol/s] for Molar Flow Rate. Kilomole per Second[mol/s], Dekamole per Second[mol/s], Mole per Minute[mol/s] are the few other units in which Stripping Section Flowrate of Liquid for given Quality of Feed can be measured.