Strip Width given Total Static Design Moment Formula

Fx Copy
LaTeX Copy
Span Perpendicular to L1 in the direction in which moments are being determined, center to center of supports. Check FAQs
l2=8MoW(ln)2
l2 - Span Perpendicular to L1?Mo - Total Static Design Moment in Strip?W - Uniform Design Load?ln - Clear Span in Direction of Moments?

Strip Width given Total Static Design Moment Example

With values
With units
Only example

Here is how the Strip Width given Total Static Design Moment equation looks like with Values.

Here is how the Strip Width given Total Static Design Moment equation looks like with Units.

Here is how the Strip Width given Total Static Design Moment equation looks like.

2Edit=8125Edit20Edit(5Edit)2
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Concrete Formulas » fx Strip Width given Total Static Design Moment

Strip Width given Total Static Design Moment Solution

Follow our step by step solution on how to calculate Strip Width given Total Static Design Moment?

FIRST Step Consider the formula
l2=8MoW(ln)2
Next Step Substitute values of Variables
l2=8125kN*m20kN/m(5m)2
Next Step Convert Units
l2=8125000N*m20000N/m(5m)2
Next Step Prepare to Evaluate
l2=812500020000(5)2
LAST Step Evaluate
l2=2m

Strip Width given Total Static Design Moment Formula Elements

Variables
Span Perpendicular to L1
Span Perpendicular to L1 in the direction in which moments are being determined, center to center of supports.
Symbol: l2
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Total Static Design Moment in Strip
Total Static Design Moment in Strip bounded laterally by the centerline of the panel on each side of the centerline of the supports.
Symbol: Mo
Measurement: Moment of ForceUnit: kN*m
Note: Value can be positive or negative.
Uniform Design Load
Uniform Design Load per unit of slab area. The design load is maximum amount of something a system is designed to handle.
Symbol: W
Measurement: Surface TensionUnit: kN/m
Note: Value can be positive or negative.
Clear Span in Direction of Moments
Clear Span in Direction of Moments being determined.
Symbol: ln
Measurement: LengthUnit: m
Note: Value can be positive or negative.

Other formulas in Flat Plate Construction category

​Go Total Static Design Moment in Strip
Mo=Wl2(ln)28
​Go Uniform Design Load Per Unit of Slab Area given Total Static Design Moment
W=Mo8l2ln2
​Go Clear Span in Direction Moments given Total Static Design Moment
ln=Mo8Wl2
​Go Concrete Column Elasticity Modulus using Flexural Stiffness
Ec=KcI

How to Evaluate Strip Width given Total Static Design Moment?

Strip Width given Total Static Design Moment evaluator uses Span Perpendicular to L1 = (8*Total Static Design Moment in Strip)/(Uniform Design Load*(Clear Span in Direction of Moments)^2) to evaluate the Span Perpendicular to L1, The Strip Width given Total Static Design Moment formula is defined by the parameters of total static design moment, uniform design load and clear span in direction moments being determined. Span Perpendicular to L1 is denoted by l2 symbol.

How to evaluate Strip Width given Total Static Design Moment using this online evaluator? To use this online evaluator for Strip Width given Total Static Design Moment, enter Total Static Design Moment in Strip (Mo), Uniform Design Load (W) & Clear Span in Direction of Moments (ln) and hit the calculate button.

FAQs on Strip Width given Total Static Design Moment

What is the formula to find Strip Width given Total Static Design Moment?
The formula of Strip Width given Total Static Design Moment is expressed as Span Perpendicular to L1 = (8*Total Static Design Moment in Strip)/(Uniform Design Load*(Clear Span in Direction of Moments)^2). Here is an example- 2 = (8*125000)/(20000*(5)^2).
How to calculate Strip Width given Total Static Design Moment?
With Total Static Design Moment in Strip (Mo), Uniform Design Load (W) & Clear Span in Direction of Moments (ln) we can find Strip Width given Total Static Design Moment using the formula - Span Perpendicular to L1 = (8*Total Static Design Moment in Strip)/(Uniform Design Load*(Clear Span in Direction of Moments)^2).
Can the Strip Width given Total Static Design Moment be negative?
Yes, the Strip Width given Total Static Design Moment, measured in Length can be negative.
Which unit is used to measure Strip Width given Total Static Design Moment?
Strip Width given Total Static Design Moment is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Strip Width given Total Static Design Moment can be measured.
Copied!