Fx Copy
LaTeX Copy
The Storage Coefficient is referred as volume of water released from storage per unit decline in hydraulic head in the aquifer, per unit area of the aquifer. Check FAQs
S=Tst640ro2
S - Storage Coefficient?T - Transmissivity?st - Total Drawdown?ro - Distance from Pumping Well to Point Intersection?

Storage Coefficient for Inconsistent Units from Distance Drawdown Graphs Example

With values
With units
Only example

Here is how the Storage Coefficient for Inconsistent Units from Distance Drawdown Graphs equation looks like with Values.

Here is how the Storage Coefficient for Inconsistent Units from Distance Drawdown Graphs equation looks like with Units.

Here is how the Storage Coefficient for Inconsistent Units from Distance Drawdown Graphs equation looks like.

0.0096Edit=11Edit0.035Edit6404Edit2
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Engineering Hydrology » fx Storage Coefficient for Inconsistent Units from Distance Drawdown Graphs

Storage Coefficient for Inconsistent Units from Distance Drawdown Graphs Solution

Follow our step by step solution on how to calculate Storage Coefficient for Inconsistent Units from Distance Drawdown Graphs?

FIRST Step Consider the formula
S=Tst640ro2
Next Step Substitute values of Variables
S=11m²/s0.035m6404m2
Next Step Prepare to Evaluate
S=110.03564042
Next Step Evaluate
S=0.009625
LAST Step Rounding Answer
S=0.0096

Storage Coefficient for Inconsistent Units from Distance Drawdown Graphs Formula Elements

Variables
Storage Coefficient
The Storage Coefficient is referred as volume of water released from storage per unit decline in hydraulic head in the aquifer, per unit area of the aquifer.
Symbol: S
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Transmissivity
Transmissivity is the rate at which groundwater flows horizontally through an aquifer or the degree to which a medium allows something, in particular electromagnetic radiation, to pass through it.
Symbol: T
Measurement: Kinematic ViscosityUnit: m²/s
Note: Value can be positive or negative.
Total Drawdown
The Total Drawdown is referred as reduction in hydraulic head observed at a well in an aquifer, typically due to pumping a well as part of an aquifer test or well test.
Symbol: st
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Distance from Pumping Well to Point Intersection
The Distance from Pumping Well to Point Intersection is referred as the straight line which intersects the zero-drawdown line.
Symbol: ro
Measurement: LengthUnit: m
Note: Value can be positive or negative.

Other Formulas to find Storage Coefficient

​Go Storage Coefficient from Distance-Drawdown Graphs
S=2.25Tstro2

Other formulas in Distance Drawdown Analysis category

​Go Transmissivity from Distance Drawdown Graphs
T=2.3q2πΔsD
​Go Pumping Rate from Distance Drawdown Graphs
q=T2πΔsD2.3
​Go Drawdown across One Log Cycle from Distance Drawdown Graphs given Transmissivity
ΔsD=2.3qT2π
​Go Transmissivity given Storage Coefficient from Distance Drawdown
T=Sro22.25st

How to Evaluate Storage Coefficient for Inconsistent Units from Distance Drawdown Graphs?

Storage Coefficient for Inconsistent Units from Distance Drawdown Graphs evaluator uses Storage Coefficient = Transmissivity*Total Drawdown/640*Distance from Pumping Well to Point Intersection^2 to evaluate the Storage Coefficient, The Storage Coefficient for Inconsistent Units from Distance Drawdown Graphs formula is defined as the volume of water released from storage per unit decline in hydraulic head in the aquifer, per unit area of the aquifer. Storage Coefficient is denoted by S symbol.

How to evaluate Storage Coefficient for Inconsistent Units from Distance Drawdown Graphs using this online evaluator? To use this online evaluator for Storage Coefficient for Inconsistent Units from Distance Drawdown Graphs, enter Transmissivity (T), Total Drawdown (st) & Distance from Pumping Well to Point Intersection (ro) and hit the calculate button.

FAQs on Storage Coefficient for Inconsistent Units from Distance Drawdown Graphs

What is the formula to find Storage Coefficient for Inconsistent Units from Distance Drawdown Graphs?
The formula of Storage Coefficient for Inconsistent Units from Distance Drawdown Graphs is expressed as Storage Coefficient = Transmissivity*Total Drawdown/640*Distance from Pumping Well to Point Intersection^2. Here is an example- 0.009625 = 11*0.035/640*4^2.
How to calculate Storage Coefficient for Inconsistent Units from Distance Drawdown Graphs?
With Transmissivity (T), Total Drawdown (st) & Distance from Pumping Well to Point Intersection (ro) we can find Storage Coefficient for Inconsistent Units from Distance Drawdown Graphs using the formula - Storage Coefficient = Transmissivity*Total Drawdown/640*Distance from Pumping Well to Point Intersection^2.
What are the other ways to Calculate Storage Coefficient?
Here are the different ways to Calculate Storage Coefficient-
  • Storage Coefficient=2.25*Transmissivity*Total Drawdown/Distance from Pumping Well to Point Intersection^2OpenImg
Copied!