Stator Conductor Cross Section Area Formula

Fx Copy
LaTeX Copy
Stator conductor cross section area can be estimated from the stator current per phase and suitably assumed value of current density for the stator windings. Check FAQs
σz=Izδs
σz - Stator Conductor Cross Section Area?Iz - Current in Conductor?δs - Current Density in Stator Conductor?

Stator Conductor Cross Section Area Example

With values
With units
Only example

Here is how the Stator Conductor Cross Section Area equation looks like with Values.

Here is how the Stator Conductor Cross Section Area equation looks like with Units.

Here is how the Stator Conductor Cross Section Area equation looks like.

3.8458Edit=9.999Edit2.6Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Electrical Machine Design » fx Stator Conductor Cross Section Area

Stator Conductor Cross Section Area Solution

Follow our step by step solution on how to calculate Stator Conductor Cross Section Area?

FIRST Step Consider the formula
σz=Izδs
Next Step Substitute values of Variables
σz=9.999A2.6A/m²
Next Step Prepare to Evaluate
σz=9.9992.6
Next Step Evaluate
σz=3.84576923076923
LAST Step Rounding Answer
σz=3.8458

Stator Conductor Cross Section Area Formula Elements

Variables
Stator Conductor Cross Section Area
Stator conductor cross section area can be estimated from the stator current per phase and suitably assumed value of current density for the stator windings.
Symbol: σz
Measurement: AreaUnit:
Note: Value should be greater than 0.
Current in Conductor
Current in conductor is ratio of per phase current to the number of parallel path present machine.
Symbol: Iz
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.
Current Density in Stator Conductor
Current density in stator conductor is the amount of electric current traveling per unit cross-section area is called as current density and expressed in amperes per square meter.
Symbol: δs
Measurement: Surface Current DensityUnit: A/m²
Note: Value should be greater than 0.

Other formulas in DC Machines category

​Go Limiting Value of Core Length
Llimit=7.5BavVaTcnc
​Go Average Gap Density using Limiting Value of Core Length
Bav=7.5LlimitVaTcnc
​Go Peripheral Speed of Armature using Limiting Value of Core Length
Va=7.5BavLlimitTcnc
​Go Number of Poles using Magnetic Loading
n=BΦ

How to Evaluate Stator Conductor Cross Section Area?

Stator Conductor Cross Section Area evaluator uses Stator Conductor Cross Section Area = Current in Conductor/Current Density in Stator Conductor to evaluate the Stator Conductor Cross Section Area, The Stator conductor cross section area is the ratio of current flowing in each conductor of stator to the current density. The cross-sectional area of a stator conductor in an electrical machine refers to the area of the conductor perpendicular to the direction of current flow. Stator Conductor Cross Section Area is denoted by σz symbol.

How to evaluate Stator Conductor Cross Section Area using this online evaluator? To use this online evaluator for Stator Conductor Cross Section Area, enter Current in Conductor (Iz) & Current Density in Stator Conductor s) and hit the calculate button.

FAQs on Stator Conductor Cross Section Area

What is the formula to find Stator Conductor Cross Section Area?
The formula of Stator Conductor Cross Section Area is expressed as Stator Conductor Cross Section Area = Current in Conductor/Current Density in Stator Conductor. Here is an example- 3.845769 = 9.999/2.6.
How to calculate Stator Conductor Cross Section Area?
With Current in Conductor (Iz) & Current Density in Stator Conductor s) we can find Stator Conductor Cross Section Area using the formula - Stator Conductor Cross Section Area = Current in Conductor/Current Density in Stator Conductor.
Can the Stator Conductor Cross Section Area be negative?
No, the Stator Conductor Cross Section Area, measured in Area cannot be negative.
Which unit is used to measure Stator Conductor Cross Section Area?
Stator Conductor Cross Section Area is usually measured using the Square Meter[m²] for Area. Square Kilometer[m²], Square Centimeter[m²], Square Millimeter[m²] are the few other units in which Stator Conductor Cross Section Area can be measured.
Copied!