Stanton number for Colburn analogy Formula

Fx Copy
LaTeX Copy
The Stanton Number is a dimensionless number that measures the ratio of heat transferred into a fluid to the thermal capacity of the fluid. Check FAQs
St=df8(Pr0.67)
St - Stanton Number?df - Darcy Friction Factor?Pr - Prandtl Number?

Stanton number for Colburn analogy Example

With values
With units
Only example

Here is how the Stanton number for Colburn analogy equation looks like with Values.

Here is how the Stanton number for Colburn analogy equation looks like with Units.

Here is how the Stanton number for Colburn analogy equation looks like.

0.0794Edit=0.5Edit8(0.7Edit0.67)
You are here -
HomeIcon Home » Category Physics » Category Mechanical » Category Heat and Mass Transfer » fx Stanton number for Colburn analogy

Stanton number for Colburn analogy Solution

Follow our step by step solution on how to calculate Stanton number for Colburn analogy?

FIRST Step Consider the formula
St=df8(Pr0.67)
Next Step Substitute values of Variables
St=0.58(0.70.67)
Next Step Prepare to Evaluate
St=0.58(0.70.67)
Next Step Evaluate
St=0.0793714529667513
LAST Step Rounding Answer
St=0.0794

Stanton number for Colburn analogy Formula Elements

Variables
Stanton Number
The Stanton Number is a dimensionless number that measures the ratio of heat transferred into a fluid to the thermal capacity of the fluid.
Symbol: St
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Darcy Friction Factor
Darcy Friction Factor is denoted by f. Its value depends on the flow's Reynolds number Re and on the pipe's relative roughness ε / D. It can be obtained from Moody's chart.
Symbol: df
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Prandtl Number
The Prandtl number (Pr) or Prandtl group is a dimensionless number, named after the German physicist Ludwig Prandtl, defined as the ratio of momentum diffusivity to thermal diffusivity.
Symbol: Pr
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.

Other formulas in Laminar Flow category

​Go Darcy friction factor
df=64ReD
​Go Reynolds Number given Darcy Friction Factor
Re=64df
​Go Hydrodynamic entry length
L=0.04DReD
​Go Diameter of hydrodynamic entry tube
D=L0.04ReD

How to Evaluate Stanton number for Colburn analogy?

Stanton number for Colburn analogy evaluator uses Stanton Number = Darcy Friction Factor/(8*(Prandtl Number^0.67)) to evaluate the Stanton Number, The Stanton number for Colburn analogy formula is defined as the ratio of heat transferred into a fluid to the thermal capacity of fluid. Stanton Number is denoted by St symbol.

How to evaluate Stanton number for Colburn analogy using this online evaluator? To use this online evaluator for Stanton number for Colburn analogy, enter Darcy Friction Factor (df) & Prandtl Number (Pr) and hit the calculate button.

FAQs on Stanton number for Colburn analogy

What is the formula to find Stanton number for Colburn analogy?
The formula of Stanton number for Colburn analogy is expressed as Stanton Number = Darcy Friction Factor/(8*(Prandtl Number^0.67)). Here is an example- 0.079371 = 0.5/(8*(0.7^0.67)).
How to calculate Stanton number for Colburn analogy?
With Darcy Friction Factor (df) & Prandtl Number (Pr) we can find Stanton number for Colburn analogy using the formula - Stanton Number = Darcy Friction Factor/(8*(Prandtl Number^0.67)).
Copied!