Stack Design Pressure Draft for Furnace Formula

Fx Copy
LaTeX Copy
Draft pressure, also known as chimney draft or flue draft, refers to the pressure difference between the inside and outside of a combustion system or chimney. Check FAQs
PDraft=0.0342(Ls)PAtm(1TAmbient-1TFlue Gas)
PDraft - Draft Pressure?Ls - Stack Height?PAtm - Atmospheric Pressure?TAmbient - Ambient Temperature?TFlue Gas - Flue Gas Temperature?

Stack Design Pressure Draft for Furnace Example

With values
With units
Only example

Here is how the Stack Design Pressure Draft for Furnace equation looks like with Values.

Here is how the Stack Design Pressure Draft for Furnace equation looks like with Units.

Here is how the Stack Design Pressure Draft for Furnace equation looks like.

11045.4996Edit=0.0342(6500Edit)100000Edit(1298.15Edit-1350Edit)
You are here -
HomeIcon Home » Category Engineering » Category Chemical Engineering » Category Process Equipment Design » fx Stack Design Pressure Draft for Furnace

Stack Design Pressure Draft for Furnace Solution

Follow our step by step solution on how to calculate Stack Design Pressure Draft for Furnace?

FIRST Step Consider the formula
PDraft=0.0342(Ls)PAtm(1TAmbient-1TFlue Gas)
Next Step Substitute values of Variables
PDraft=0.0342(6500mm)100000Pa(1298.15K-1350K)
Next Step Convert Units
PDraft=0.0342(6.5m)100000Pa(1298.15K-1350K)
Next Step Prepare to Evaluate
PDraft=0.0342(6.5)100000(1298.15-1350)
Next Step Evaluate
PDraft=11.0454996286625m
Next Step Convert to Output's Unit
PDraft=11045.4996286625mm
LAST Step Rounding Answer
PDraft=11045.4996mm

Stack Design Pressure Draft for Furnace Formula Elements

Variables
Draft Pressure
Draft pressure, also known as chimney draft or flue draft, refers to the pressure difference between the inside and outside of a combustion system or chimney.
Symbol: PDraft
Measurement: LengthUnit: mm
Note: Value should be greater than 0.
Stack Height
Stack Height is the height of chimney/ furnace which is used to vent the combustion gases and emissions produced during heating/combustion.
Symbol: Ls
Measurement: LengthUnit: mm
Note: Value should be greater than 0.
Atmospheric Pressure
Atmospheric Pressure is the pressure exerted by the atmosphere on to the surface of Earth.
Symbol: PAtm
Measurement: PressureUnit: Pa
Note: Value should be greater than 0.
Ambient Temperature
Ambient Temperature refers to the temperature of the surrounding air or environment at a specific location.
Symbol: TAmbient
Measurement: TemperatureUnit: K
Note: Value should be greater than 0.
Flue Gas Temperature
Flue gas temperature refers to the temperature of the gases that are produced as a byproduct of combustion in various processes, such as in industrial furnaces.
Symbol: TFlue Gas
Measurement: TemperatureUnit: K
Note: Value should be greater than 0.

Other formulas in Basic Formulas of Heat Exchanger Designs category

​Go Equivalent Diameter for Square Pitch in Heat Exchanger
De=(1.27DOuter)((PTube2)-0.785(DOuter2))
​Go Equivalent Diameter for Triangular Pitch in Heat Exchanger
De=(1.10DOuter)((PTube2)-0.917(DOuter2))
​Go Number of Baffles in Shell and Tube Heat Exchanger
NBaffles=(LTubeLBaffle)-1
​Go Number of Tubes in Center Row Given Bundle Diameter and Tube Pitch
Nr=DBPTube

How to Evaluate Stack Design Pressure Draft for Furnace?

Stack Design Pressure Draft for Furnace evaluator uses Draft Pressure = 0.0342*(Stack Height)*Atmospheric Pressure*(1/Ambient Temperature-1/Flue Gas Temperature) to evaluate the Draft Pressure, The Stack Design Pressure Draft for Furnace formula is defined as pressure inside the combustion chamber/ furnace during operations. This pressure ensures that the flames and combustion process remain contained within the furnace. Draft Pressure is denoted by PDraft symbol.

How to evaluate Stack Design Pressure Draft for Furnace using this online evaluator? To use this online evaluator for Stack Design Pressure Draft for Furnace, enter Stack Height (Ls), Atmospheric Pressure (PAtm), Ambient Temperature (TAmbient) & Flue Gas Temperature (TFlue Gas) and hit the calculate button.

FAQs on Stack Design Pressure Draft for Furnace

What is the formula to find Stack Design Pressure Draft for Furnace?
The formula of Stack Design Pressure Draft for Furnace is expressed as Draft Pressure = 0.0342*(Stack Height)*Atmospheric Pressure*(1/Ambient Temperature-1/Flue Gas Temperature). Here is an example- 1.1E+7 = 0.0342*(6.5)*100000*(1/298.15-1/350).
How to calculate Stack Design Pressure Draft for Furnace?
With Stack Height (Ls), Atmospheric Pressure (PAtm), Ambient Temperature (TAmbient) & Flue Gas Temperature (TFlue Gas) we can find Stack Design Pressure Draft for Furnace using the formula - Draft Pressure = 0.0342*(Stack Height)*Atmospheric Pressure*(1/Ambient Temperature-1/Flue Gas Temperature).
Can the Stack Design Pressure Draft for Furnace be negative?
No, the Stack Design Pressure Draft for Furnace, measured in Length cannot be negative.
Which unit is used to measure Stack Design Pressure Draft for Furnace?
Stack Design Pressure Draft for Furnace is usually measured using the Millimeter[mm] for Length. Meter[mm], Kilometer[mm], Decimeter[mm] are the few other units in which Stack Design Pressure Draft for Furnace can be measured.
Copied!