Fx Copy
LaTeX Copy
Conduction shape factor is defined as the value used to determine the heat transfer rate for the configurations which are very complex and require high calculation time. Check FAQs
S=2πLpipe0.785ln(wo2wi2)
S - Conduction Shape Factor?Lpipe - Length of Pipe?wo2 - Outer Width 2?wi2 - Inner Width 2?π - Archimedes' constant?

Square Flow Passage with Width to b Ratio Less than 1.4 Example

With values
With units
Only example

Here is how the Square Flow Passage with Width to b Ratio Less than 1.4 equation looks like with Values.

Here is how the Square Flow Passage with Width to b Ratio Less than 1.4 equation looks like with Units.

Here is how the Square Flow Passage with Width to b Ratio Less than 1.4 equation looks like.

28Edit=23.14160.1Edit0.785ln(6.174Edit6Edit)
You are here -
HomeIcon Home » Category Physics » Category Mechanical » Category Heat and Mass Transfer » fx Square Flow Passage with Width to b Ratio Less than 1.4

Square Flow Passage with Width to b Ratio Less than 1.4 Solution

Follow our step by step solution on how to calculate Square Flow Passage with Width to b Ratio Less than 1.4?

FIRST Step Consider the formula
S=2πLpipe0.785ln(wo2wi2)
Next Step Substitute values of Variables
S=2π0.1m0.785ln(6.174m6m)
Next Step Substitute values of Constants
S=23.14160.1m0.785ln(6.174m6m)
Next Step Prepare to Evaluate
S=23.14160.10.785ln(6.1746)
Next Step Evaluate
S=28.0000000070978m
LAST Step Rounding Answer
S=28m

Square Flow Passage with Width to b Ratio Less than 1.4 Formula Elements

Variables
Constants
Functions
Conduction Shape Factor
Conduction shape factor is defined as the value used to determine the heat transfer rate for the configurations which are very complex and require high calculation time.
Symbol: S
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Length of Pipe
Length of Pipe describes the length of the pipe in which the liquid is flowing.
Symbol: Lpipe
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Outer Width 2
Outer width 2 is the side length of the outer part of the pipe, duct, or passage of the cross-section shape other than the circle.
Symbol: wo2
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Inner Width 2
Inner Width 2 is the side length of the inner part of the pipe, duct, or passage of the cross-section shape other than the circle.
Symbol: wi2
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Archimedes' constant
Archimedes' constant is a mathematical constant that represents the ratio of the circumference of a circle to its diameter.
Symbol: π
Value: 3.14159265358979323846264338327950288
ln
The natural logarithm, also known as the logarithm to the base e, is the inverse function of the natural exponential function.
Syntax: ln(Number)

Other Formulas to find Conduction Shape Factor

​Go Isothermal Cylinder at Center of Square Solid Bar of Same Length
S=2πLcln(1.08wD)
​Go Eccentric Isothermal Cylinder in Cylinder of Same Length
S=2πLcacosh(D12+D22-4z22D1D2)
​Go Large Plane Wall
S=At
​Go Long Hollow Cylindrical Layer
S=2πLcln(r2r1)

How to Evaluate Square Flow Passage with Width to b Ratio Less than 1.4?

Square Flow Passage with Width to b Ratio Less than 1.4 evaluator uses Conduction Shape Factor = (2*pi*Length of Pipe)/(0.785*ln(Outer Width 2/Inner Width 2)) to evaluate the Conduction Shape Factor, Square Flow Passage with Width to b Ratio Less than 1.4 formula is defined as a dimensionless quantity that characterizes the flow passage geometry in a pipe, where the width to b ratio is less than 1.4, and is used to analyze and design piping systems in various engineering applications. Conduction Shape Factor is denoted by S symbol.

How to evaluate Square Flow Passage with Width to b Ratio Less than 1.4 using this online evaluator? To use this online evaluator for Square Flow Passage with Width to b Ratio Less than 1.4, enter Length of Pipe (Lpipe), Outer Width 2 (wo2) & Inner Width 2 (wi2) and hit the calculate button.

FAQs on Square Flow Passage with Width to b Ratio Less than 1.4

What is the formula to find Square Flow Passage with Width to b Ratio Less than 1.4?
The formula of Square Flow Passage with Width to b Ratio Less than 1.4 is expressed as Conduction Shape Factor = (2*pi*Length of Pipe)/(0.785*ln(Outer Width 2/Inner Width 2)). Here is an example- -0.901658 = (2*pi*0.1)/(0.785*ln(6.173990514/6)).
How to calculate Square Flow Passage with Width to b Ratio Less than 1.4?
With Length of Pipe (Lpipe), Outer Width 2 (wo2) & Inner Width 2 (wi2) we can find Square Flow Passage with Width to b Ratio Less than 1.4 using the formula - Conduction Shape Factor = (2*pi*Length of Pipe)/(0.785*ln(Outer Width 2/Inner Width 2)). This formula also uses Archimedes' constant and Natural Logarithm Function function(s).
What are the other ways to Calculate Conduction Shape Factor?
Here are the different ways to Calculate Conduction Shape Factor-
  • Conduction Shape Factor=(2*pi*Length of Cylinder)/ln((1.08*Width of Square Bar)/Diameter of Cylinder)OpenImg
  • Conduction Shape Factor=(2*pi*Length of Cylinder)/acosh((Diameter of Cylinder 1^2+Diameter of Cylinder 2^2-4*Eccentric Distance Between Objects^2)/(2*Diameter of Cylinder 1*Diameter of Cylinder 2))OpenImg
  • Conduction Shape Factor=Cross-Sectional Area/ThicknessOpenImg
Can the Square Flow Passage with Width to b Ratio Less than 1.4 be negative?
No, the Square Flow Passage with Width to b Ratio Less than 1.4, measured in Length cannot be negative.
Which unit is used to measure Square Flow Passage with Width to b Ratio Less than 1.4?
Square Flow Passage with Width to b Ratio Less than 1.4 is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Square Flow Passage with Width to b Ratio Less than 1.4 can be measured.
Copied!