Specific Weight of Fill Material given Load Per Unit Length for Flexible Pipes Formula

Fx Copy
LaTeX Copy
The Specific Weight of Fill refers to the weight per unit volume of fill. Check FAQs
γ=(WCDw)
γ - Specific Weight of Fill?W - Load per unit Length?C - Coefficient of Fill?D - External Diameter?w - Width?

Specific Weight of Fill Material given Load Per Unit Length for Flexible Pipes Example

With values
With units
Only example

Here is how the Specific Weight of Fill Material given Load Per Unit Length for Flexible Pipes equation looks like with Values.

Here is how the Specific Weight of Fill Material given Load Per Unit Length for Flexible Pipes equation looks like with Units.

Here is how the Specific Weight of Fill Material given Load Per Unit Length for Flexible Pipes equation looks like.

3.2023Edit=(22Edit1.5Edit2Edit2.29Edit)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Specific Weight of Fill Material given Load Per Unit Length for Flexible Pipes

Specific Weight of Fill Material given Load Per Unit Length for Flexible Pipes Solution

Follow our step by step solution on how to calculate Specific Weight of Fill Material given Load Per Unit Length for Flexible Pipes?

FIRST Step Consider the formula
γ=(WCDw)
Next Step Substitute values of Variables
γ=(22kN/m1.52m2.29m)
Next Step Convert Units
γ=(22000N/m1.52m2.29m)
Next Step Prepare to Evaluate
γ=(220001.522.29)
Next Step Evaluate
γ=3202.32896652111N/m³
Next Step Convert to Output's Unit
γ=3.20232896652111kN/m³
LAST Step Rounding Answer
γ=3.2023kN/m³

Specific Weight of Fill Material given Load Per Unit Length for Flexible Pipes Formula Elements

Variables
Specific Weight of Fill
The Specific Weight of Fill refers to the weight per unit volume of fill.
Symbol: γ
Measurement: Specific WeightUnit: kN/m³
Note: Value should be greater than 0.
Load per unit Length
The Load per unit Length refers to the load applied per unit length of the pipe.
Symbol: W
Measurement: Surface TensionUnit: kN/m
Note: Value should be greater than 0.
Coefficient of Fill
The Coefficient of Fill refers to the constant dependent on the nature of the fill.
Symbol: C
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
External Diameter
The External Diameter refers to the outer diameter of the pipe.
Symbol: D
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Width
The Width refers to the measurement or extent of something from side to side.
Symbol: w
Measurement: LengthUnit: m
Note: Value can be positive or negative.

Other formulas in Flexible Pipes category

​Go Load Per Unit Length for Flexible Pipes
W=CγwD
​Go Width of Trench given Load Per Unit Length for Flexible Pipes
w=(WCDγ)

How to Evaluate Specific Weight of Fill Material given Load Per Unit Length for Flexible Pipes?

Specific Weight of Fill Material given Load Per Unit Length for Flexible Pipes evaluator uses Specific Weight of Fill = (Load per unit Length/(Coefficient of Fill*External Diameter*Width)) to evaluate the Specific Weight of Fill, The Specific Weight of Fill Material given Load Per Unit Length for Flexible Pipes is simply mass per unit volume of a body, where as specific weight is the weight per unit volume of a body. Specific Weight of Fill is denoted by γ symbol.

How to evaluate Specific Weight of Fill Material given Load Per Unit Length for Flexible Pipes using this online evaluator? To use this online evaluator for Specific Weight of Fill Material given Load Per Unit Length for Flexible Pipes, enter Load per unit Length (W), Coefficient of Fill (C), External Diameter (D) & Width (w) and hit the calculate button.

FAQs on Specific Weight of Fill Material given Load Per Unit Length for Flexible Pipes

What is the formula to find Specific Weight of Fill Material given Load Per Unit Length for Flexible Pipes?
The formula of Specific Weight of Fill Material given Load Per Unit Length for Flexible Pipes is expressed as Specific Weight of Fill = (Load per unit Length/(Coefficient of Fill*External Diameter*Width)). Here is an example- 0.002444 = (22000/(1.5*2*2.29)).
How to calculate Specific Weight of Fill Material given Load Per Unit Length for Flexible Pipes?
With Load per unit Length (W), Coefficient of Fill (C), External Diameter (D) & Width (w) we can find Specific Weight of Fill Material given Load Per Unit Length for Flexible Pipes using the formula - Specific Weight of Fill = (Load per unit Length/(Coefficient of Fill*External Diameter*Width)).
Can the Specific Weight of Fill Material given Load Per Unit Length for Flexible Pipes be negative?
No, the Specific Weight of Fill Material given Load Per Unit Length for Flexible Pipes, measured in Specific Weight cannot be negative.
Which unit is used to measure Specific Weight of Fill Material given Load Per Unit Length for Flexible Pipes?
Specific Weight of Fill Material given Load Per Unit Length for Flexible Pipes is usually measured using the Kilonewton per Cubic Meter[kN/m³] for Specific Weight. Newton per Cubic Meter[kN/m³], Newton per Cubic Centimeter[kN/m³], Newton per Cubic Millimeter[kN/m³] are the few other units in which Specific Weight of Fill Material given Load Per Unit Length for Flexible Pipes can be measured.
Copied!