Fx Copy
LaTeX Copy
Specific Resistance of The Electrolyte is the measure of how strongly it opposes the flow of current through them. Check FAQs
re=RAgh
re - Specific Resistance of The Electrolyte?R - Resistance of Gap Between Work And Tool?Ag - Cross Sectional Area of Gap?h - Gap Between Tool And Work Surface?

Specific Resistance of Electrolyte Example

With values
With units
Only example

Here is how the Specific Resistance of Electrolyte equation looks like with Values.

Here is how the Specific Resistance of Electrolyte equation looks like with Units.

Here is how the Specific Resistance of Electrolyte equation looks like.

3Edit=0.012Edit6.25Edit0.25Edit
You are here -
HomeIcon Home » Category Engineering » Category Production Engineering » Category Metal Machining » fx Specific Resistance of Electrolyte

Specific Resistance of Electrolyte Solution

Follow our step by step solution on how to calculate Specific Resistance of Electrolyte?

FIRST Step Consider the formula
re=RAgh
Next Step Substitute values of Variables
re=0.012Ω6.25cm²0.25mm
Next Step Convert Units
re=0.012Ω0.00060.0002m
Next Step Prepare to Evaluate
re=0.0120.00060.0002
Next Step Evaluate
re=0.03Ω*m
LAST Step Convert to Output's Unit
re=3Ω*cm

Specific Resistance of Electrolyte Formula Elements

Variables
Specific Resistance of The Electrolyte
Specific Resistance of The Electrolyte is the measure of how strongly it opposes the flow of current through them.
Symbol: re
Measurement: Electric ResistivityUnit: Ω*cm
Note: Value should be greater than 0.
Resistance of Gap Between Work And Tool
Resistance of Gap Between Work And Tool, often referred to as the "gap" in machining processes, depends on various factors such as the material being machined, the tool material and geometry.
Symbol: R
Measurement: Electric ResistanceUnit: Ω
Note: Value should be greater than 0.
Cross Sectional Area of Gap
The Cross Sectional Area of Gap is defined as the cross-sectional area of the equilibrium gap which is required to maintain the desired electrolytic effect between tool and workpiece.
Symbol: Ag
Measurement: AreaUnit: cm²
Note: Value should be greater than 0.
Gap Between Tool And Work Surface
The Gap between Tool and Work Surface is the stretch of the distance between tool and work Surface during Electrochemical Machining.
Symbol: h
Measurement: LengthUnit: mm
Note: Value should be greater than 0.

Other Formulas to find Specific Resistance of The Electrolyte

​Go Specific Resistivity of Electrolyte given Supply Current
re=AVshI
​Go Specific Resistivity of Electrolyte given Gap between Tool and Work Surface
re=ηeVsehρVf

Other formulas in Gap Resistance category

​Go Gap between Tool and Work Surface given Supply Current
h=AVsreI
​Go Gap between Tool and Work Surface
h=ηeVsereρVf
​Go Density of Work Material given Gap between Tool and Work Surface
ρ=ηeVsereVfh
​Go Gap Resistance between Work and Tool
R=rehAg

How to Evaluate Specific Resistance of Electrolyte?

Specific Resistance of Electrolyte evaluator uses Specific Resistance of The Electrolyte = (Resistance of Gap Between Work And Tool*Cross Sectional Area of Gap)/Gap Between Tool And Work Surface to evaluate the Specific Resistance of The Electrolyte, The Specific resistance of electrolyte formula is defined as the resistivity of the electrolyte used in the ECM. Specific Resistance of The Electrolyte is denoted by re symbol.

How to evaluate Specific Resistance of Electrolyte using this online evaluator? To use this online evaluator for Specific Resistance of Electrolyte, enter Resistance of Gap Between Work And Tool (R), Cross Sectional Area of Gap (Ag) & Gap Between Tool And Work Surface (h) and hit the calculate button.

FAQs on Specific Resistance of Electrolyte

What is the formula to find Specific Resistance of Electrolyte?
The formula of Specific Resistance of Electrolyte is expressed as Specific Resistance of The Electrolyte = (Resistance of Gap Between Work And Tool*Cross Sectional Area of Gap)/Gap Between Tool And Work Surface. Here is an example- 300 = (0.012*0.000625)/0.00025.
How to calculate Specific Resistance of Electrolyte?
With Resistance of Gap Between Work And Tool (R), Cross Sectional Area of Gap (Ag) & Gap Between Tool And Work Surface (h) we can find Specific Resistance of Electrolyte using the formula - Specific Resistance of The Electrolyte = (Resistance of Gap Between Work And Tool*Cross Sectional Area of Gap)/Gap Between Tool And Work Surface.
What are the other ways to Calculate Specific Resistance of The Electrolyte?
Here are the different ways to Calculate Specific Resistance of The Electrolyte-
  • Specific Resistance of The Electrolyte=Area of Penetration*Supply Voltage/(Gap Between Tool And Work Surface*Electric Current)OpenImg
  • Specific Resistance of The Electrolyte=Current Efficiency in Decimal*Supply Voltage*Electrochemical Equivalent/(Gap Between Tool And Work Surface*Work Piece Density*Feed Speed)OpenImg
Can the Specific Resistance of Electrolyte be negative?
No, the Specific Resistance of Electrolyte, measured in Electric Resistivity cannot be negative.
Which unit is used to measure Specific Resistance of Electrolyte?
Specific Resistance of Electrolyte is usually measured using the Ohm Centimeter[Ω*cm] for Electric Resistivity. Ohm Meter[Ω*cm], Ohm Inch[Ω*cm], Microhm Centimeter[Ω*cm] are the few other units in which Specific Resistance of Electrolyte can be measured.
Copied!