Fx Copy
LaTeX Copy
The Specific Capacity refers to the measure used in hydrogeology to evaluate the efficiency of a well, defined as the amount of water a well can produce per unit of drawdown. Check FAQs
Sc=(QCQn+BQ)
Sc - Specific Capacity?Q - Discharge?CQn - Head Loss in Well?BQ - Aquifer Loss?

Specific Capacity given Aquifer Loss Example

With values
With units
Only example

Here is how the Specific Capacity given Aquifer Loss equation looks like with Values.

Here is how the Specific Capacity given Aquifer Loss equation looks like with Units.

Here is how the Specific Capacity given Aquifer Loss equation looks like.

0.0359Edit=(1.01Edit0.52Edit+27.6Edit)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Specific Capacity given Aquifer Loss

Specific Capacity given Aquifer Loss Solution

Follow our step by step solution on how to calculate Specific Capacity given Aquifer Loss?

FIRST Step Consider the formula
Sc=(QCQn+BQ)
Next Step Substitute values of Variables
Sc=(1.01m³/s0.52m+27.6m)
Next Step Prepare to Evaluate
Sc=(1.010.52+27.6)
Next Step Evaluate
Sc=0.0359174964438122m²/s
LAST Step Rounding Answer
Sc=0.0359m²/s

Specific Capacity given Aquifer Loss Formula Elements

Variables
Specific Capacity
The Specific Capacity refers to the measure used in hydrogeology to evaluate the efficiency of a well, defined as the amount of water a well can produce per unit of drawdown.
Symbol: Sc
Measurement: Kinematic ViscosityUnit: m²/s
Note: Value should be greater than 0.
Discharge
Discharge is the rate of flow of a liquid.
Symbol: Q
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value can be positive or negative.
Head Loss in Well
The Head Loss in Well refers to the difference between the head of the aquifer immediately outside and in the well a head inside because of all these losses.
Symbol: CQn
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Aquifer Loss
The Aquifer Loss refers to the reduction in the volume of water stored in an aquifer.
Symbol: BQ
Measurement: LengthUnit: m
Note: Value should be greater than 0.

Other Formulas to find Specific Capacity

​Go Specific Capacity given Drawdown
Sc=Qst

Other formulas in Specific Capacity of Well category

​Go Drawdown given Specific Capacity of Well
st=QSc
​Go Discharge given Specific Capacity
Q=Scst
​Go Aquifer Loss given Specific Capacity
BQ=(QSc)-CQn
​Go Well Discharge given Specific Capacity
Q=Sc(CQn+BQ)

How to Evaluate Specific Capacity given Aquifer Loss?

Specific Capacity given Aquifer Loss evaluator uses Specific Capacity = (Discharge/(Head Loss in Well+Aquifer Loss)) to evaluate the Specific Capacity, The Specific Capacity given Aquifer Loss formula is defined as the measure of the ability of an aquifer to transmit water under certain conditions, taking into account the well loss and aquifer loss components, which are critical in understanding groundwater flow and managing water resources effectively. Specific Capacity is denoted by Sc symbol.

How to evaluate Specific Capacity given Aquifer Loss using this online evaluator? To use this online evaluator for Specific Capacity given Aquifer Loss, enter Discharge (Q), Head Loss in Well (CQn) & Aquifer Loss (BQ) and hit the calculate button.

FAQs on Specific Capacity given Aquifer Loss

What is the formula to find Specific Capacity given Aquifer Loss?
The formula of Specific Capacity given Aquifer Loss is expressed as Specific Capacity = (Discharge/(Head Loss in Well+Aquifer Loss)). Here is an example- 0.036528 = (1.01/(0.52+27.6)).
How to calculate Specific Capacity given Aquifer Loss?
With Discharge (Q), Head Loss in Well (CQn) & Aquifer Loss (BQ) we can find Specific Capacity given Aquifer Loss using the formula - Specific Capacity = (Discharge/(Head Loss in Well+Aquifer Loss)).
What are the other ways to Calculate Specific Capacity?
Here are the different ways to Calculate Specific Capacity-
  • Specific Capacity=Discharge/Total DrawdownOpenImg
Can the Specific Capacity given Aquifer Loss be negative?
No, the Specific Capacity given Aquifer Loss, measured in Kinematic Viscosity cannot be negative.
Which unit is used to measure Specific Capacity given Aquifer Loss?
Specific Capacity given Aquifer Loss is usually measured using the Square Meter per Second[m²/s] for Kinematic Viscosity. Square Meter per Hour[m²/s], Square Centimeter per Second[m²/s], Square Millimeter per Second[m²/s] are the few other units in which Specific Capacity given Aquifer Loss can be measured.
Copied!