Fx Copy
LaTeX Copy
Space Time in Mixed Flow is the time necessary to process volume of reactor fluid at the entrance conditions. Check FAQs
𝛕mixed=Xmfr(1-Xmfr)2(kmixed)(Co)
𝛕mixed - Space Time in Mixed Flow?Xmfr - Reactant Conversion in Mixed Flow?kmixed - Rate Constant for Second Order in Mixed Flow?Co - Initial Reactant Concentration in Mixed Flow?

Space Time for Second Order Reaction for Mixed Flow Example

With values
With units
Only example

Here is how the Space Time for Second Order Reaction for Mixed Flow equation looks like with Values.

Here is how the Space Time for Second Order Reaction for Mixed Flow equation looks like with Units.

Here is how the Space Time for Second Order Reaction for Mixed Flow equation looks like.

0.1733Edit=0.71Edit(1-0.71Edit)2(0.609Edit)(80Edit)
You are here -
HomeIcon Home » Category Engineering » Category Chemical Engineering » Category Chemical Reaction Engineering » fx Space Time for Second Order Reaction for Mixed Flow

Space Time for Second Order Reaction for Mixed Flow Solution

Follow our step by step solution on how to calculate Space Time for Second Order Reaction for Mixed Flow?

FIRST Step Consider the formula
𝛕mixed=Xmfr(1-Xmfr)2(kmixed)(Co)
Next Step Substitute values of Variables
𝛕mixed=0.71(1-0.71)2(0.609m³/(mol*s))(80mol/m³)
Next Step Prepare to Evaluate
𝛕mixed=0.71(1-0.71)2(0.609)(80)
Next Step Evaluate
𝛕mixed=0.173282646938803s
LAST Step Rounding Answer
𝛕mixed=0.1733s

Space Time for Second Order Reaction for Mixed Flow Formula Elements

Variables
Space Time in Mixed Flow
Space Time in Mixed Flow is the time necessary to process volume of reactor fluid at the entrance conditions.
Symbol: 𝛕mixed
Measurement: TimeUnit: s
Note: Value should be greater than 0.
Reactant Conversion in Mixed Flow
Reactant Conversion in Mixed Flow gives us the percentage of reactants converted into products. Enter the percentage as a decimal between 0 and 1.
Symbol: Xmfr
Measurement: NAUnit: Unitless
Note: Value should be less than 1.
Rate Constant for Second Order in Mixed Flow
The Rate Constant for Second Order in Mixed Flow is defined as the average rate of the reaction per concentration of the reactant having power raised to 2.
Symbol: kmixed
Measurement: Second Order Reaction Rate ConstantUnit: m³/(mol*s)
Note: Value should be greater than 0.
Initial Reactant Concentration in Mixed Flow
The Initial Reactant Concentration in Mixed Flow refers to the amount of reactant present in the solvent before the considered process.
Symbol: Co
Measurement: Molar ConcentrationUnit: mol/m³
Note: Value should be greater than 0.

Other Formulas to find Space Time in Mixed Flow

​Go Space Time for First Order Reaction for Mixed Flow
𝛕mixed=(1k')(Xmfr1-Xmfr)
​Go Space Time for First Order Reaction using Reactant Concentration for Mixed Flow
𝛕mixed=(1k')(Co-CC)
​Go Space Time for Second Order Reaction using Reactant Concentration for Mixed Flow
𝛕mixed=Co-C(kmixed)(C)2
​Go Space Time for Zero Order Reaction for Mixed Flow
𝛕mixed=XmfrCokmixed flow

Other formulas in Mixed Flow category

​Go Initial Reactant Concentration for Second Order Reaction using Space Time for Mixed Flow
Co=Xmfr(1-Xmfr)2(𝛕mixed)(kmixed)
​Go Initial Reactant Concentration for Zero Order Reaction using Space Time for Mixed Flow
Co=kmixed flow𝛕mixedXmfr
​Go Rate Constant for First Order Reaction using Reactant Concentration for Mixed Flow
k'=(1𝛕mixed)(Co-CC)
​Go Rate Constant for First Order Reaction using Space Time for Mixed Flow
k'=(1𝛕mixed)(Xmfr1-Xmfr)

How to Evaluate Space Time for Second Order Reaction for Mixed Flow?

Space Time for Second Order Reaction for Mixed Flow evaluator uses Space Time in Mixed Flow = (Reactant Conversion in Mixed Flow)/((1-Reactant Conversion in Mixed Flow)^2*(Rate Constant for Second Order in Mixed Flow)*(Initial Reactant Concentration in Mixed Flow)) to evaluate the Space Time in Mixed Flow, The Space Time for Second Order Reaction for Mixed Flow formula is defined as the time necessary to process volume of reactor fluid for second order reaction where fractional volume change is zero for mixed flow. Space Time in Mixed Flow is denoted by 𝛕mixed symbol.

How to evaluate Space Time for Second Order Reaction for Mixed Flow using this online evaluator? To use this online evaluator for Space Time for Second Order Reaction for Mixed Flow, enter Reactant Conversion in Mixed Flow (Xmfr), Rate Constant for Second Order in Mixed Flow (kmixed) & Initial Reactant Concentration in Mixed Flow (Co) and hit the calculate button.

FAQs on Space Time for Second Order Reaction for Mixed Flow

What is the formula to find Space Time for Second Order Reaction for Mixed Flow?
The formula of Space Time for Second Order Reaction for Mixed Flow is expressed as Space Time in Mixed Flow = (Reactant Conversion in Mixed Flow)/((1-Reactant Conversion in Mixed Flow)^2*(Rate Constant for Second Order in Mixed Flow)*(Initial Reactant Concentration in Mixed Flow)). Here is an example- 0.173283 = (0.71)/((1-0.71)^2*(0.609)*(80)).
How to calculate Space Time for Second Order Reaction for Mixed Flow?
With Reactant Conversion in Mixed Flow (Xmfr), Rate Constant for Second Order in Mixed Flow (kmixed) & Initial Reactant Concentration in Mixed Flow (Co) we can find Space Time for Second Order Reaction for Mixed Flow using the formula - Space Time in Mixed Flow = (Reactant Conversion in Mixed Flow)/((1-Reactant Conversion in Mixed Flow)^2*(Rate Constant for Second Order in Mixed Flow)*(Initial Reactant Concentration in Mixed Flow)).
What are the other ways to Calculate Space Time in Mixed Flow?
Here are the different ways to Calculate Space Time in Mixed Flow-
  • Space Time in Mixed Flow=(1/Rate Constant for First Order Reaction)*(Reactant Conversion in Mixed Flow/(1-Reactant Conversion in Mixed Flow))OpenImg
  • Space Time in Mixed Flow=(1/Rate Constant for First Order Reaction)*((Initial Reactant Concentration in Mixed Flow-Reactant Concentration at given Time)/Reactant Concentration at given Time)OpenImg
  • Space Time in Mixed Flow=(Initial Reactant Concentration in Mixed Flow-Reactant Concentration at given Time)/((Rate Constant for Second Order in Mixed Flow)*(Reactant Concentration at given Time)^2)OpenImg
Can the Space Time for Second Order Reaction for Mixed Flow be negative?
No, the Space Time for Second Order Reaction for Mixed Flow, measured in Time cannot be negative.
Which unit is used to measure Space Time for Second Order Reaction for Mixed Flow?
Space Time for Second Order Reaction for Mixed Flow is usually measured using the Second[s] for Time. Millisecond[s], Microsecond[s], Nanosecond[s] are the few other units in which Space Time for Second Order Reaction for Mixed Flow can be measured.
Copied!