The Amount of Solute in Underflow leaving column is the amount of the solute leaving in the Underflow of the continuous leaching operation. Check FAQs
SN=S0(1-Recovery)
SN - Amount of Solute in Underflow Leaving Column?S0 - Amount of Solute in Underflow Entering Column?Recovery - Recovery of Solute in Leaching Column?

Solute Underflow Leaving Column based on Recovery of Solute Example

With values
With units
Only example

Here is how the Solute Underflow Leaving Column based on Recovery of Solute equation looks like with Values.

Here is how the Solute Underflow Leaving Column based on Recovery of Solute equation looks like with Units.

Here is how the Solute Underflow Leaving Column based on Recovery of Solute equation looks like.

1.97Edit=9.85Edit(1-0.8Edit)
You are here -
HomeIcon Home » Category Engineering » Category Chemical Engineering » Category Mass Transfer Operations » fx Solute Underflow Leaving Column based on Recovery of Solute

Solute Underflow Leaving Column based on Recovery of Solute Solution

Follow our step by step solution on how to calculate Solute Underflow Leaving Column based on Recovery of Solute?

FIRST Step Consider the formula
SN=S0(1-Recovery)
Next Step Substitute values of Variables
SN=9.85kg/s(1-0.8)
Next Step Prepare to Evaluate
SN=9.85(1-0.8)
LAST Step Evaluate
SN=1.97kg/s

Solute Underflow Leaving Column based on Recovery of Solute Formula Elements

Variables
Amount of Solute in Underflow Leaving Column
The Amount of Solute in Underflow leaving column is the amount of the solute leaving in the Underflow of the continuous leaching operation.
Symbol: SN
Measurement: Mass Flow RateUnit: kg/s
Note: Value should be greater than 0.
Amount of Solute in Underflow Entering Column
The Amount of Solute in Underflow entering column is the amount of the solute entering in the Underflow of the continuous leaching operation.
Symbol: S0
Measurement: Mass Flow RateUnit: kg/s
Note: Value should be greater than 0.
Recovery of Solute in Leaching Column
The Recovery of Solute in Leaching column is defined as the ratio of the amount of solute recovered to the amount of solute feed into the column.
Symbol: Recovery
Measurement: NAUnit: Unitless
Note: Value should be less than 1.

Other Formulas to find Amount of Solute in Underflow Leaving Column

​Go Solute Underflow Leaving Column based on Ratio of Overflow to Underflow
SN=S0(R-1)(RN+1)-1

Other formulas in Counter Current Continuous Leaching for Constant Overflow (Pure Solvent) category

​Go Area of Contact for Batch Leaching Operation
A=(-VLeachingKLt)ln((CS-CCS))
​Go Concentration of Solute in Bulk Solution at Time t for Batch Leaching
C=CS(1-exp(-KLAtVLeaching))
​Go Time of Batch Leaching Operation
t=(-VLeachingAKL)ln((CS-CCS))
​Go Volume of Leaching Solution in Batch Leaching
VLeaching=-KLAtln((CS-CCS))

How to Evaluate Solute Underflow Leaving Column based on Recovery of Solute?

Solute Underflow Leaving Column based on Recovery of Solute evaluator uses Amount of Solute in Underflow Leaving Column = Amount of Solute in Underflow Entering Column*(1-Recovery of Solute in Leaching Column) to evaluate the Amount of Solute in Underflow Leaving Column, The Solute Underflow Leaving Column based on Recovery of Solute formula is defined as the Solute Underflow that leaves the Continuous Leaching operation based on recovery of solute. Amount of Solute in Underflow Leaving Column is denoted by SN symbol.

How to evaluate Solute Underflow Leaving Column based on Recovery of Solute using this online evaluator? To use this online evaluator for Solute Underflow Leaving Column based on Recovery of Solute, enter Amount of Solute in Underflow Entering Column (S0) & Recovery of Solute in Leaching Column (Recovery) and hit the calculate button.

FAQs on Solute Underflow Leaving Column based on Recovery of Solute

What is the formula to find Solute Underflow Leaving Column based on Recovery of Solute?
The formula of Solute Underflow Leaving Column based on Recovery of Solute is expressed as Amount of Solute in Underflow Leaving Column = Amount of Solute in Underflow Entering Column*(1-Recovery of Solute in Leaching Column). Here is an example- 1.97 = 9.85*(1-0.8).
How to calculate Solute Underflow Leaving Column based on Recovery of Solute?
With Amount of Solute in Underflow Entering Column (S0) & Recovery of Solute in Leaching Column (Recovery) we can find Solute Underflow Leaving Column based on Recovery of Solute using the formula - Amount of Solute in Underflow Leaving Column = Amount of Solute in Underflow Entering Column*(1-Recovery of Solute in Leaching Column).
What are the other ways to Calculate Amount of Solute in Underflow Leaving Column?
Here are the different ways to Calculate Amount of Solute in Underflow Leaving Column-
  • Amount of Solute in Underflow Leaving Column=(Amount of Solute in Underflow Entering Column*(Ratio of Discharge in Overflow to Underflow-1))/((Ratio of Discharge in Overflow to Underflow^(Number of Equilibrium Stages in Leaching+1))-1)OpenImg
Can the Solute Underflow Leaving Column based on Recovery of Solute be negative?
No, the Solute Underflow Leaving Column based on Recovery of Solute, measured in Mass Flow Rate cannot be negative.
Which unit is used to measure Solute Underflow Leaving Column based on Recovery of Solute?
Solute Underflow Leaving Column based on Recovery of Solute is usually measured using the Kilogram per Second[kg/s] for Mass Flow Rate. Gram per Second[kg/s], Gram per Hour[kg/s], Milligram per Minute[kg/s] are the few other units in which Solute Underflow Leaving Column based on Recovery of Solute can be measured.
Copied!