Fx Copy
LaTeX Copy
The Amount of Solute in Underflow entering column is the amount of the solute entering in the Underflow of the continuous leaching operation. Check FAQs
S0=SN((RN+1)-1)R-1
S0 - Amount of Solute in Underflow Entering Column?SN - Amount of Solute in Underflow Leaving Column?R - Ratio of Discharge in Overflow to Underflow?N - Number of Equilibrium Stages in Leaching?

Solute Underflow Entering Column based on Ratio of Overflow to Underflow Example

With values
With units
Only example

Here is how the Solute Underflow Entering Column based on Ratio of Overflow to Underflow equation looks like with Values.

Here is how the Solute Underflow Entering Column based on Ratio of Overflow to Underflow equation looks like with Units.

Here is how the Solute Underflow Entering Column based on Ratio of Overflow to Underflow equation looks like.

10.6211Edit=2Edit((1.35Edit2.5Edit+1)-1)1.35Edit-1
You are here -
HomeIcon Home » Category Engineering » Category Chemical Engineering » Category Mass Transfer Operations » fx Solute Underflow Entering Column based on Ratio of Overflow to Underflow

Solute Underflow Entering Column based on Ratio of Overflow to Underflow Solution

Follow our step by step solution on how to calculate Solute Underflow Entering Column based on Ratio of Overflow to Underflow?

FIRST Step Consider the formula
S0=SN((RN+1)-1)R-1
Next Step Substitute values of Variables
S0=2kg/s((1.352.5+1)-1)1.35-1
Next Step Prepare to Evaluate
S0=2((1.352.5+1)-1)1.35-1
Next Step Evaluate
S0=10.6211281150144kg/s
LAST Step Rounding Answer
S0=10.6211kg/s

Solute Underflow Entering Column based on Ratio of Overflow to Underflow Formula Elements

Variables
Amount of Solute in Underflow Entering Column
The Amount of Solute in Underflow entering column is the amount of the solute entering in the Underflow of the continuous leaching operation.
Symbol: S0
Measurement: Mass Flow RateUnit: kg/s
Note: Value should be greater than 0.
Amount of Solute in Underflow Leaving Column
The Amount of Solute in Underflow leaving column is the amount of the solute leaving in the Underflow of the continuous leaching operation.
Symbol: SN
Measurement: Mass Flow RateUnit: kg/s
Note: Value should be greater than 0.
Ratio of Discharge in Overflow to Underflow
The Ratio of Discharge in Overflow to Underflow is the ratio of the solution, solvent or solute discharge in the overflow to that in the underflow.
Symbol: R
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Number of Equilibrium Stages in Leaching
The Number of Equilibrium Stages in Leaching is the Number of mass transfer stages in leaching operation required to attain a specified level of solid concentration.
Symbol: N
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.

Other Formulas to find Amount of Solute in Underflow Entering Column

​Go Solute Underflow Entering Column based on Recovery of Solute
S0=SN1-Recovery

Other formulas in Counter Current Continuous Leaching for Constant Overflow (Pure Solvent) category

​Go Area of Contact for Batch Leaching Operation
A=(-VLeachingKLt)ln((CS-CCS))
​Go Concentration of Solute in Bulk Solution at Time t for Batch Leaching
C=CS(1-exp(-KLAtVLeaching))
​Go Time of Batch Leaching Operation
t=(-VLeachingAKL)ln((CS-CCS))
​Go Volume of Leaching Solution in Batch Leaching
VLeaching=-KLAtln((CS-CCS))

How to Evaluate Solute Underflow Entering Column based on Ratio of Overflow to Underflow?

Solute Underflow Entering Column based on Ratio of Overflow to Underflow evaluator uses Amount of Solute in Underflow Entering Column = (Amount of Solute in Underflow Leaving Column*((Ratio of Discharge in Overflow to Underflow^(Number of Equilibrium Stages in Leaching+1))-1))/(Ratio of Discharge in Overflow to Underflow-1) to evaluate the Amount of Solute in Underflow Entering Column, The Solute Underflow Entering Column based on Ratio of Overflow to Underflow formula is defined as Solute underflow i.e. solute with solid entering the column calculated based on Ratio of Underflow to Overflow and Number of Equilibrum Stages. Amount of Solute in Underflow Entering Column is denoted by S0 symbol.

How to evaluate Solute Underflow Entering Column based on Ratio of Overflow to Underflow using this online evaluator? To use this online evaluator for Solute Underflow Entering Column based on Ratio of Overflow to Underflow, enter Amount of Solute in Underflow Leaving Column (SN), Ratio of Discharge in Overflow to Underflow (R) & Number of Equilibrium Stages in Leaching (N) and hit the calculate button.

FAQs on Solute Underflow Entering Column based on Ratio of Overflow to Underflow

What is the formula to find Solute Underflow Entering Column based on Ratio of Overflow to Underflow?
The formula of Solute Underflow Entering Column based on Ratio of Overflow to Underflow is expressed as Amount of Solute in Underflow Entering Column = (Amount of Solute in Underflow Leaving Column*((Ratio of Discharge in Overflow to Underflow^(Number of Equilibrium Stages in Leaching+1))-1))/(Ratio of Discharge in Overflow to Underflow-1). Here is an example- 10.62113 = (2*((1.35^(2.5+1))-1))/(1.35-1).
How to calculate Solute Underflow Entering Column based on Ratio of Overflow to Underflow?
With Amount of Solute in Underflow Leaving Column (SN), Ratio of Discharge in Overflow to Underflow (R) & Number of Equilibrium Stages in Leaching (N) we can find Solute Underflow Entering Column based on Ratio of Overflow to Underflow using the formula - Amount of Solute in Underflow Entering Column = (Amount of Solute in Underflow Leaving Column*((Ratio of Discharge in Overflow to Underflow^(Number of Equilibrium Stages in Leaching+1))-1))/(Ratio of Discharge in Overflow to Underflow-1).
What are the other ways to Calculate Amount of Solute in Underflow Entering Column?
Here are the different ways to Calculate Amount of Solute in Underflow Entering Column-
  • Amount of Solute in Underflow Entering Column=Amount of Solute in Underflow Leaving Column/(1-Recovery of Solute in Leaching Column)OpenImg
Can the Solute Underflow Entering Column based on Ratio of Overflow to Underflow be negative?
No, the Solute Underflow Entering Column based on Ratio of Overflow to Underflow, measured in Mass Flow Rate cannot be negative.
Which unit is used to measure Solute Underflow Entering Column based on Ratio of Overflow to Underflow?
Solute Underflow Entering Column based on Ratio of Overflow to Underflow is usually measured using the Kilogram per Second[kg/s] for Mass Flow Rate. Gram per Second[kg/s], Gram per Hour[kg/s], Milligram per Minute[kg/s] are the few other units in which Solute Underflow Entering Column based on Ratio of Overflow to Underflow can be measured.
Copied!