Fx Copy
LaTeX Copy
The Amount of Solute in Underflow entering column is the amount of the solute entering in the Underflow of the continuous leaching operation. Check FAQs
S0=SNf
S0 - Amount of Solute in Underflow Entering Column?SN - Amount of Solute in Underflow Leaving Column?f - Fractional Solute Discharge?

Solute Underflow Entering Column based on Fractional Solute Discharge Example

With values
With units
Only example

Here is how the Solute Underflow Entering Column based on Fractional Solute Discharge equation looks like with Values.

Here is how the Solute Underflow Entering Column based on Fractional Solute Discharge equation looks like with Units.

Here is how the Solute Underflow Entering Column based on Fractional Solute Discharge equation looks like.

10Edit=2Edit0.2Edit
You are here -
HomeIcon Home » Category Engineering » Category Chemical Engineering » Category Mass Transfer Operations » fx Solute Underflow Entering Column based on Fractional Solute Discharge

Solute Underflow Entering Column based on Fractional Solute Discharge Solution

Follow our step by step solution on how to calculate Solute Underflow Entering Column based on Fractional Solute Discharge?

FIRST Step Consider the formula
S0=SNf
Next Step Substitute values of Variables
S0=2kg/s0.2
Next Step Prepare to Evaluate
S0=20.2
LAST Step Evaluate
S0=10kg/s

Solute Underflow Entering Column based on Fractional Solute Discharge Formula Elements

Variables
Amount of Solute in Underflow Entering Column
The Amount of Solute in Underflow entering column is the amount of the solute entering in the Underflow of the continuous leaching operation.
Symbol: S0
Measurement: Mass Flow RateUnit: kg/s
Note: Value should be greater than 0.
Amount of Solute in Underflow Leaving Column
The Amount of Solute in Underflow leaving column is the amount of the solute leaving in the Underflow of the continuous leaching operation.
Symbol: SN
Measurement: Mass Flow RateUnit: kg/s
Note: Value should be greater than 0.
Fractional Solute Discharge
The Fractional Solute Discharge is the ratio of the Solute exiting the stage of continuous leaching to that entering the stage.
Symbol: f
Measurement: NAUnit: Unitless
Note: Value should be less than 1.

Other Formulas to find Amount of Solute in Underflow Entering Column

​Go Solute Underflow Entering Column based on Recovery of Solute
S0=SN1-Recovery
​Go Solute Underflow Entering Column based on Ratio of Overflow to Underflow
S0=SN((RN+1)-1)R-1

Other formulas in Counter Current Continuous Leaching for Constant Overflow (Pure Solvent) category

​Go Ratio of Solute Discharged in Underflow to Overflow
R=LS
​Go Ratio of Solvent Discharged in Underflow to Overflow
R=V-LW-S
​Go Ratio of Solution Discharged in Overflow to Underflow
R=VW
​Go Solute Discharged in Overflow based on Ratio of Overflow to Underflow
L=RS

How to Evaluate Solute Underflow Entering Column based on Fractional Solute Discharge?

Solute Underflow Entering Column based on Fractional Solute Discharge evaluator uses Amount of Solute in Underflow Entering Column = Amount of Solute in Underflow Leaving Column/Fractional Solute Discharge to evaluate the Amount of Solute in Underflow Entering Column, The Solute Underflow Entering Column based on Fractional Solute Discharge formula is defined as the amount of solute in underflow entering the column calculated from the fraction ratio of solute discharge. Amount of Solute in Underflow Entering Column is denoted by S0 symbol.

How to evaluate Solute Underflow Entering Column based on Fractional Solute Discharge using this online evaluator? To use this online evaluator for Solute Underflow Entering Column based on Fractional Solute Discharge, enter Amount of Solute in Underflow Leaving Column (SN) & Fractional Solute Discharge (f) and hit the calculate button.

FAQs on Solute Underflow Entering Column based on Fractional Solute Discharge

What is the formula to find Solute Underflow Entering Column based on Fractional Solute Discharge?
The formula of Solute Underflow Entering Column based on Fractional Solute Discharge is expressed as Amount of Solute in Underflow Entering Column = Amount of Solute in Underflow Leaving Column/Fractional Solute Discharge. Here is an example- 10 = 2/0.2.
How to calculate Solute Underflow Entering Column based on Fractional Solute Discharge?
With Amount of Solute in Underflow Leaving Column (SN) & Fractional Solute Discharge (f) we can find Solute Underflow Entering Column based on Fractional Solute Discharge using the formula - Amount of Solute in Underflow Entering Column = Amount of Solute in Underflow Leaving Column/Fractional Solute Discharge.
What are the other ways to Calculate Amount of Solute in Underflow Entering Column?
Here are the different ways to Calculate Amount of Solute in Underflow Entering Column-
  • Amount of Solute in Underflow Entering Column=Amount of Solute in Underflow Leaving Column/(1-Recovery of Solute in Leaching Column)OpenImg
  • Amount of Solute in Underflow Entering Column=(Amount of Solute in Underflow Leaving Column*((Ratio of Discharge in Overflow to Underflow^(Number of Equilibrium Stages in Leaching+1))-1))/(Ratio of Discharge in Overflow to Underflow-1)OpenImg
Can the Solute Underflow Entering Column based on Fractional Solute Discharge be negative?
No, the Solute Underflow Entering Column based on Fractional Solute Discharge, measured in Mass Flow Rate cannot be negative.
Which unit is used to measure Solute Underflow Entering Column based on Fractional Solute Discharge?
Solute Underflow Entering Column based on Fractional Solute Discharge is usually measured using the Kilogram per Second[kg/s] for Mass Flow Rate. Gram per Second[kg/s], Gram per Hour[kg/s], Milligram per Minute[kg/s] are the few other units in which Solute Underflow Entering Column based on Fractional Solute Discharge can be measured.
Copied!