Solute Discharged in Overflow based on Ratio of Overflow to Underflow and Solution Discharged Formula

Fx Copy
LaTeX Copy
The Amount of Solute Discharge in Overflow is the amount of the solute discharged in the Overflow of the continuous leaching operation. Check FAQs
L=V-R(W-S)
L - Amount of Solute Discharge in Overflow?V - Amount of Solution Discharge in Overflow?R - Ratio of Discharge in Overflow to Underflow?W - Amount of Solution Discharge in Underflow?S - Amount of Solute Discharge in Underflow?

Solute Discharged in Overflow based on Ratio of Overflow to Underflow and Solution Discharged Example

With values
With units
Only example

Here is how the Solute Discharged in Overflow based on Ratio of Overflow to Underflow and Solution Discharged equation looks like with Values.

Here is how the Solute Discharged in Overflow based on Ratio of Overflow to Underflow and Solution Discharged equation looks like with Units.

Here is how the Solute Discharged in Overflow based on Ratio of Overflow to Underflow and Solution Discharged equation looks like.

0.5037Edit=1.01Edit-1.35Edit(0.75Edit-0.375Edit)
You are here -
HomeIcon Home » Category Engineering » Category Chemical Engineering » Category Mass Transfer Operations » fx Solute Discharged in Overflow based on Ratio of Overflow to Underflow and Solution Discharged

Solute Discharged in Overflow based on Ratio of Overflow to Underflow and Solution Discharged Solution

Follow our step by step solution on how to calculate Solute Discharged in Overflow based on Ratio of Overflow to Underflow and Solution Discharged?

FIRST Step Consider the formula
L=V-R(W-S)
Next Step Substitute values of Variables
L=1.01kg/s-1.35(0.75kg/s-0.375kg/s)
Next Step Prepare to Evaluate
L=1.01-1.35(0.75-0.375)
Next Step Evaluate
L=0.50375kg/s
LAST Step Rounding Answer
L=0.5037kg/s

Solute Discharged in Overflow based on Ratio of Overflow to Underflow and Solution Discharged Formula Elements

Variables
Amount of Solute Discharge in Overflow
The Amount of Solute Discharge in Overflow is the amount of the solute discharged in the Overflow of the continuous leaching operation.
Symbol: L
Measurement: Mass Flow RateUnit: kg/s
Note: Value should be greater than 0.
Amount of Solution Discharge in Overflow
The Amount of Solution Discharge in Overflow is the amount of the solution discharged in the Overflow of the continuous leaching operation.
Symbol: V
Measurement: Mass Flow RateUnit: kg/s
Note: Value should be greater than 0.
Ratio of Discharge in Overflow to Underflow
The Ratio of Discharge in Overflow to Underflow is the ratio of the solution, solvent or solute discharge in the overflow to that in the underflow.
Symbol: R
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Amount of Solution Discharge in Underflow
The Amount of Solution Discharge in Underflow is the amount of the solution discharged in the Underflow of the continuous leaching operation.
Symbol: W
Measurement: Mass Flow RateUnit: kg/s
Note: Value should be greater than 0.
Amount of Solute Discharge in Underflow
The Amount of Solute Discharge in Underflow is the amount of the solute discharged in the Underflow of the continuous leaching operation.
Symbol: S
Measurement: Mass Flow RateUnit: kg/s
Note: Value should be greater than 0.

Other formulas in Counter Current Continuous Leaching for Constant Overflow (Pure Solvent) category

​Go Area of Contact for Batch Leaching Operation
A=(-VLeachingKLt)ln((CS-CCS))
​Go Concentration of Solute in Bulk Solution at Time t for Batch Leaching
C=CS(1-exp(-KLAtVLeaching))
​Go Time of Batch Leaching Operation
t=(-VLeachingAKL)ln((CS-CCS))
​Go Volume of Leaching Solution in Batch Leaching
VLeaching=-KLAtln((CS-CCS))

How to Evaluate Solute Discharged in Overflow based on Ratio of Overflow to Underflow and Solution Discharged?

Solute Discharged in Overflow based on Ratio of Overflow to Underflow and Solution Discharged evaluator uses Amount of Solute Discharge in Overflow = Amount of Solution Discharge in Overflow-Ratio of Discharge in Overflow to Underflow*(Amount of Solution Discharge in Underflow-Amount of Solute Discharge in Underflow) to evaluate the Amount of Solute Discharge in Overflow, The Solute Discharged in Overflow based on Ratio of Overflow to Underflow and Solution Discharged formula is defined as the Amount of Solute Discharge in Overflow based on the Ratio of Overflow o Underflow and solution discharged values. Amount of Solute Discharge in Overflow is denoted by L symbol.

How to evaluate Solute Discharged in Overflow based on Ratio of Overflow to Underflow and Solution Discharged using this online evaluator? To use this online evaluator for Solute Discharged in Overflow based on Ratio of Overflow to Underflow and Solution Discharged, enter Amount of Solution Discharge in Overflow (V), Ratio of Discharge in Overflow to Underflow (R), Amount of Solution Discharge in Underflow (W) & Amount of Solute Discharge in Underflow (S) and hit the calculate button.

FAQs on Solute Discharged in Overflow based on Ratio of Overflow to Underflow and Solution Discharged

What is the formula to find Solute Discharged in Overflow based on Ratio of Overflow to Underflow and Solution Discharged?
The formula of Solute Discharged in Overflow based on Ratio of Overflow to Underflow and Solution Discharged is expressed as Amount of Solute Discharge in Overflow = Amount of Solution Discharge in Overflow-Ratio of Discharge in Overflow to Underflow*(Amount of Solution Discharge in Underflow-Amount of Solute Discharge in Underflow). Here is an example- 0.50375 = 1.01-1.35*(0.75-0.375).
How to calculate Solute Discharged in Overflow based on Ratio of Overflow to Underflow and Solution Discharged?
With Amount of Solution Discharge in Overflow (V), Ratio of Discharge in Overflow to Underflow (R), Amount of Solution Discharge in Underflow (W) & Amount of Solute Discharge in Underflow (S) we can find Solute Discharged in Overflow based on Ratio of Overflow to Underflow and Solution Discharged using the formula - Amount of Solute Discharge in Overflow = Amount of Solution Discharge in Overflow-Ratio of Discharge in Overflow to Underflow*(Amount of Solution Discharge in Underflow-Amount of Solute Discharge in Underflow).
Can the Solute Discharged in Overflow based on Ratio of Overflow to Underflow and Solution Discharged be negative?
No, the Solute Discharged in Overflow based on Ratio of Overflow to Underflow and Solution Discharged, measured in Mass Flow Rate cannot be negative.
Which unit is used to measure Solute Discharged in Overflow based on Ratio of Overflow to Underflow and Solution Discharged?
Solute Discharged in Overflow based on Ratio of Overflow to Underflow and Solution Discharged is usually measured using the Kilogram per Second[kg/s] for Mass Flow Rate. Gram per Second[kg/s], Gram per Hour[kg/s], Milligram per Minute[kg/s] are the few other units in which Solute Discharged in Overflow based on Ratio of Overflow to Underflow and Solution Discharged can be measured.
Copied!