Fx Copy
LaTeX Copy
Slip in Induction Motor is the relative speed between the rotating magnetic flux and rotor expressed in terms of per unit synchronous speed. It is a dimensionless quantity. Check FAQs
s=frf
s - Slip?fr - Rotor Frequency?f - Frequency?

Slip given Frequency in Induction Motor Example

With values
With units
Only example

Here is how the Slip given Frequency in Induction Motor equation looks like with Values.

Here is how the Slip given Frequency in Induction Motor equation looks like with Units.

Here is how the Slip given Frequency in Induction Motor equation looks like.

0.1877Edit=10.25Edit54.6Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Machine » fx Slip given Frequency in Induction Motor

Slip given Frequency in Induction Motor Solution

Follow our step by step solution on how to calculate Slip given Frequency in Induction Motor?

FIRST Step Consider the formula
s=frf
Next Step Substitute values of Variables
s=10.25Hz54.6Hz
Next Step Prepare to Evaluate
s=10.2554.6
Next Step Evaluate
s=0.187728937728938
LAST Step Rounding Answer
s=0.1877

Slip given Frequency in Induction Motor Formula Elements

Variables
Slip
Slip in Induction Motor is the relative speed between the rotating magnetic flux and rotor expressed in terms of per unit synchronous speed. It is a dimensionless quantity.
Symbol: s
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Rotor Frequency
Rotor frequency is the number of cycles per second of the rotor.
Symbol: fr
Measurement: FrequencyUnit: Hz
Note: Value can be positive or negative.
Frequency
Frequency is the rate at which current changes direction per second. It is measured in hertz (Hz).
Symbol: f
Measurement: FrequencyUnit: Hz
Note: Value should be greater than 0.

Other Formulas to find Slip

​Go Slip at Pull Out Torque
s=R2Rth2+(Xth+X2)2
​Go Breakdown Slip of Induction Motor
s=RX
​Go Slip given Efficiency in Induction Motor
s=1-η
​Go Slip of Motor in Induction Motor
s=Ns-NmNs

How to Evaluate Slip given Frequency in Induction Motor?

Slip given Frequency in Induction Motor evaluator uses Slip = Rotor Frequency/Frequency to evaluate the Slip, Slip given Frequency in Induction Motor is defined as the difference between Synchronous Speed (Speed of rotation of magnetic field) and Rotor Speed. Slip is denoted by s symbol.

How to evaluate Slip given Frequency in Induction Motor using this online evaluator? To use this online evaluator for Slip given Frequency in Induction Motor, enter Rotor Frequency (fr) & Frequency (f) and hit the calculate button.

FAQs on Slip given Frequency in Induction Motor

What is the formula to find Slip given Frequency in Induction Motor?
The formula of Slip given Frequency in Induction Motor is expressed as Slip = Rotor Frequency/Frequency. Here is an example- 0.187729 = 10.25/54.6.
How to calculate Slip given Frequency in Induction Motor?
With Rotor Frequency (fr) & Frequency (f) we can find Slip given Frequency in Induction Motor using the formula - Slip = Rotor Frequency/Frequency.
What are the other ways to Calculate Slip?
Here are the different ways to Calculate Slip-
  • Slip=Referred Resistance/sqrt(Thevenin Resistance^2+(Thevenin Reactance+Referred Reactance)^2)OpenImg
  • Slip=Resistance/ReactanceOpenImg
  • Slip=1-EfficiencyOpenImg
Copied!