Shunt Adjustable Resistance for Series Type Ohmmeter Formula

Fx Copy
LaTeX Copy
Zero Adjusting Resistance refers to a variable resistor used to calibrate or adjust the zero reading of a measuring instrument. Check FAQs
R2=IfRhRmE-(IfRh)
R2 - Zero Adjusting Resistance?If - Current Full Scale Reading?Rh - Half Scale Resistance?Rm - Meter Resistance?E - Voltage Source?

Shunt Adjustable Resistance for Series Type Ohmmeter Example

With values
With units
Only example

Here is how the Shunt Adjustable Resistance for Series Type Ohmmeter equation looks like with Values.

Here is how the Shunt Adjustable Resistance for Series Type Ohmmeter equation looks like with Units.

Here is how the Shunt Adjustable Resistance for Series Type Ohmmeter equation looks like.

35.7143Edit=0.2Edit25Edit75Edit15.5Edit-(0.2Edit25Edit)
You are here -
HomeIcon Home » Category Engineering » Category Electronics and Instrumentation » Category Measuring Instrument Circuits » fx Shunt Adjustable Resistance for Series Type Ohmmeter

Shunt Adjustable Resistance for Series Type Ohmmeter Solution

Follow our step by step solution on how to calculate Shunt Adjustable Resistance for Series Type Ohmmeter?

FIRST Step Consider the formula
R2=IfRhRmE-(IfRh)
Next Step Substitute values of Variables
R2=0.2A25Ω75Ω15.5V-(0.2A25Ω)
Next Step Prepare to Evaluate
R2=0.2257515.5-(0.225)
Next Step Evaluate
R2=35.7142857142857Ω
LAST Step Rounding Answer
R2=35.7143Ω

Shunt Adjustable Resistance for Series Type Ohmmeter Formula Elements

Variables
Zero Adjusting Resistance
Zero Adjusting Resistance refers to a variable resistor used to calibrate or adjust the zero reading of a measuring instrument.
Symbol: R2
Measurement: Electric ResistanceUnit: Ω
Note: Value should be greater than 0.
Current Full Scale Reading
Current Full Scale Reading represents the maximum current that the ohmmeter will pass through the resistor when it's being measured at its highest resistance value.
Symbol: If
Measurement: Electric CurrentUnit: A
Note: Value should be greater than 0.
Half Scale Resistance
Half Scale Resistance refers to the resistance value halfway between the maximum and minimum resistance of a variable resistor or potentiometer, typically used to calibrate or set reference points.
Symbol: Rh
Measurement: Electric ResistanceUnit: Ω
Note: Value should be greater than 0.
Meter Resistance
Meter Resistance refers to the internal resistance of a measuring instrument. This resistance is inherent to the design of the instrument and affects the accuracy of measurements made by the device.
Symbol: Rm
Measurement: Electric ResistanceUnit: Ω
Note: Value should be greater than 0.
Voltage Source
Voltage Source refers to as a fundamental element that supplies electrical energy to a circuit.
Symbol: E
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.

Other formulas in Series Type category

​Go Current Limiting Resistance for Series Type Ohmmeter
R1=Rh-(IfRmRhE)
​Go Half Scale Resistance for Series Type Ohmmeter
Rh=ER2IfR2+IfRm

How to Evaluate Shunt Adjustable Resistance for Series Type Ohmmeter?

Shunt Adjustable Resistance for Series Type Ohmmeter evaluator uses Zero Adjusting Resistance = (Current Full Scale Reading*Half Scale Resistance*Meter Resistance)/(Voltage Source-(Current Full Scale Reading*Half Scale Resistance)) to evaluate the Zero Adjusting Resistance, The Shunt Adjustable Resistance for Series Type Ohmmeter formula is defined as a variable resistor (shunt resistor) connected in parallel with the meter movement and the unknown resistance being measured. This resistor is adjustable and allows for fine-tuning the sensitivity of the ohmmeter across its measurement range. It is also known as zero adjusting resistance. Zero Adjusting Resistance is denoted by R2 symbol.

How to evaluate Shunt Adjustable Resistance for Series Type Ohmmeter using this online evaluator? To use this online evaluator for Shunt Adjustable Resistance for Series Type Ohmmeter, enter Current Full Scale Reading (If), Half Scale Resistance (Rh), Meter Resistance (Rm) & Voltage Source (E) and hit the calculate button.

FAQs on Shunt Adjustable Resistance for Series Type Ohmmeter

What is the formula to find Shunt Adjustable Resistance for Series Type Ohmmeter?
The formula of Shunt Adjustable Resistance for Series Type Ohmmeter is expressed as Zero Adjusting Resistance = (Current Full Scale Reading*Half Scale Resistance*Meter Resistance)/(Voltage Source-(Current Full Scale Reading*Half Scale Resistance)). Here is an example- 3.095238 = (0.2*25*75)/(15.5-(0.2*25)).
How to calculate Shunt Adjustable Resistance for Series Type Ohmmeter?
With Current Full Scale Reading (If), Half Scale Resistance (Rh), Meter Resistance (Rm) & Voltage Source (E) we can find Shunt Adjustable Resistance for Series Type Ohmmeter using the formula - Zero Adjusting Resistance = (Current Full Scale Reading*Half Scale Resistance*Meter Resistance)/(Voltage Source-(Current Full Scale Reading*Half Scale Resistance)).
Can the Shunt Adjustable Resistance for Series Type Ohmmeter be negative?
No, the Shunt Adjustable Resistance for Series Type Ohmmeter, measured in Electric Resistance cannot be negative.
Which unit is used to measure Shunt Adjustable Resistance for Series Type Ohmmeter?
Shunt Adjustable Resistance for Series Type Ohmmeter is usually measured using the Ohm[Ω] for Electric Resistance. Megohm[Ω], Microhm[Ω], Volt per Ampere[Ω] are the few other units in which Shunt Adjustable Resistance for Series Type Ohmmeter can be measured.
Copied!