Fx Copy
LaTeX Copy
Shear Capacity is the shear strength of a material or component against the type of yield or structural failure when the material or component fails in shear. Check FAQs
Vu=23760kAw(Htw)2
Vu - Shear Capacity?k - Effective Length Factor?Aw - Web Area?H - Height of Web?tw - Web Thickness?

Shear Capacity if Web Slenderness is greater than 1.25 alpha Example

With values
With units
Only example

Here is how the Shear Capacity if Web Slenderness is greater than 1.25 alpha equation looks like with Values.

Here is how the Shear Capacity if Web Slenderness is greater than 1.25 alpha equation looks like with Units.

Here is how the Shear Capacity if Web Slenderness is greater than 1.25 alpha equation looks like.

6.3112Edit=237605Edit85Edit(2000Edit50Edit)2
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Design of Steel Structures » fx Shear Capacity if Web Slenderness is greater than 1.25 alpha

Shear Capacity if Web Slenderness is greater than 1.25 alpha Solution

Follow our step by step solution on how to calculate Shear Capacity if Web Slenderness is greater than 1.25 alpha?

FIRST Step Consider the formula
Vu=23760kAw(Htw)2
Next Step Substitute values of Variables
Vu=23760585mm²(2000mm50mm)2
Next Step Convert Units
Vu=23760585mm²(2m0.05m)2
Next Step Prepare to Evaluate
Vu=23760585(20.05)2
Next Step Evaluate
Vu=6311.25N
Next Step Convert to Output's Unit
Vu=6.31125kN
LAST Step Rounding Answer
Vu=6.3112kN

Shear Capacity if Web Slenderness is greater than 1.25 alpha Formula Elements

Variables
Shear Capacity
Shear Capacity is the shear strength of a material or component against the type of yield or structural failure when the material or component fails in shear.
Symbol: Vu
Measurement: ForceUnit: kN
Note: Value should be greater than 0.
Effective Length Factor
Effective Length Factor used for the members in the frame is the ratio of compression member stiffness to the end restraint stiffness.
Symbol: k
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Web Area
Web Area is the cross-sectional area of the web of a structural member, such as an I-beam or a H-beam.
Symbol: Aw
Measurement: AreaUnit: mm²
Note: Value should be greater than 0.
Height of Web
Height of Web is the vertical distance between the top and bottom edges of the web section of a structural member, such as an I-beam or a T-beam.
Symbol: H
Measurement: LengthUnit: mm
Note: Value should be greater than 0.
Web Thickness
Web Thickness is the thickness of the web of a steel structural member, such as an I-beam, H-beam, or channel section. The web is the vertical, central part of these beams that connects the flanges.
Symbol: tw
Measurement: LengthUnit: mm
Note: Value should be greater than 0.

Other Formulas to find Shear Capacity

​Go Shear Capacity for Web Slenderness less than Alpha
Vu=0.54FywAw
​Go Shear Capacity if Web Slenderness is between 1 and 1.25 alpha
Vu=0.54FywAwαHtw

How to Evaluate Shear Capacity if Web Slenderness is greater than 1.25 alpha?

Shear Capacity if Web Slenderness is greater than 1.25 alpha evaluator uses Shear Capacity = (23760*Effective Length Factor*Web Area)/(Height of Web/Web Thickness)^2 to evaluate the Shear Capacity, The Shear Capacity if Web Slenderness is greater than 1.25 alpha formula is defined as the shear strength of the web section when the slenderness ration is more than specified separation value. Shear Capacity is denoted by Vu symbol.

How to evaluate Shear Capacity if Web Slenderness is greater than 1.25 alpha using this online evaluator? To use this online evaluator for Shear Capacity if Web Slenderness is greater than 1.25 alpha, enter Effective Length Factor (k), Web Area (Aw), Height of Web (H) & Web Thickness (tw) and hit the calculate button.

FAQs on Shear Capacity if Web Slenderness is greater than 1.25 alpha

What is the formula to find Shear Capacity if Web Slenderness is greater than 1.25 alpha?
The formula of Shear Capacity if Web Slenderness is greater than 1.25 alpha is expressed as Shear Capacity = (23760*Effective Length Factor*Web Area)/(Height of Web/Web Thickness)^2. Here is an example- 0.006311 = (23760*5*8.5E-05)/(2/0.05)^2.
How to calculate Shear Capacity if Web Slenderness is greater than 1.25 alpha?
With Effective Length Factor (k), Web Area (Aw), Height of Web (H) & Web Thickness (tw) we can find Shear Capacity if Web Slenderness is greater than 1.25 alpha using the formula - Shear Capacity = (23760*Effective Length Factor*Web Area)/(Height of Web/Web Thickness)^2.
What are the other ways to Calculate Shear Capacity?
Here are the different ways to Calculate Shear Capacity-
  • Shear Capacity=0.54*Specified Minimum Yield Stress*Web AreaOpenImg
  • Shear Capacity=(0.54*Specified Minimum Yield Stress*Web Area*Separation Ratio)/(Height of Web/Web Thickness)OpenImg
Can the Shear Capacity if Web Slenderness is greater than 1.25 alpha be negative?
No, the Shear Capacity if Web Slenderness is greater than 1.25 alpha, measured in Force cannot be negative.
Which unit is used to measure Shear Capacity if Web Slenderness is greater than 1.25 alpha?
Shear Capacity if Web Slenderness is greater than 1.25 alpha is usually measured using the Kilonewton[kN] for Force. Newton[kN], Exanewton[kN], Meganewton[kN] are the few other units in which Shear Capacity if Web Slenderness is greater than 1.25 alpha can be measured.
Copied!