Sewage Flow into Aeration Tank given Organic Loading Formula

Fx Copy
LaTeX Copy
Sewage Flow into the aeration tank is the sewage flow into the aeration tank when we have prior information of other parameters used. Check FAQs
Q=VVLBODi
Q - Sewage Flow?V - Volume of Tank?VL - Organic Loading?BODi - BOD Influent?

Sewage Flow into Aeration Tank given Organic Loading Example

With values
With units
Only example

Here is how the Sewage Flow into Aeration Tank given Organic Loading equation looks like with Values.

Here is how the Sewage Flow into Aeration Tank given Organic Loading equation looks like with Units.

Here is how the Sewage Flow into Aeration Tank given Organic Loading equation looks like.

19.9958Edit=8.99Edit1.23Edit0.553Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Sewage Flow into Aeration Tank given Organic Loading

Sewage Flow into Aeration Tank given Organic Loading Solution

Follow our step by step solution on how to calculate Sewage Flow into Aeration Tank given Organic Loading?

FIRST Step Consider the formula
Q=VVLBODi
Next Step Substitute values of Variables
Q=8.991.23mg/L0.553mg/L
Next Step Convert Units
Q=8.990.0012kg/m³0.0006kg/m³
Next Step Prepare to Evaluate
Q=8.990.00120.0006
Next Step Evaluate
Q=19.9958408679928
LAST Step Rounding Answer
Q=19.9958

Sewage Flow into Aeration Tank given Organic Loading Formula Elements

Variables
Sewage Flow
Sewage Flow into the aeration tank is the sewage flow into the aeration tank when we have prior information of other parameters used.
Symbol: Q
Measurement: VolumeUnit:
Note: Value should be greater than 0.
Volume of Tank
Volume of Tank is defined as the capacity of flocculation and mixing tank.
Symbol: V
Measurement: VolumeUnit:
Note: Value should be greater than 0.
Organic Loading
Organic Loading is the amount of organic matter, typically measured as biochemical oxygen demand or chemical oxygen demand, that is introduced into a wastewater treatment system.
Symbol: VL
Measurement: DensityUnit: mg/L
Note: Value should be greater than 0.
BOD Influent
BOD Influent is the concentration of Biochemical Oxygen Demand (BOD) in the incoming wastewater entering a treatment facility.
Symbol: BODi
Measurement: DensityUnit: mg/L
Note: Value should be greater than 0.

Other formulas in Volumetric BOD Loading category

​Go Volumetric BOD Loading or Organic Loading
VL=Bod_massV
​Go Mass of BOD Applied Per Day given Organic Loading
Bod_mass=VVL
​Go Organic Loading given BOD of influent Sewage
VL=QBODiV
​Go Volume of Aeration Tank given Organic Loading
V=QBODiVL

How to Evaluate Sewage Flow into Aeration Tank given Organic Loading?

Sewage Flow into Aeration Tank given Organic Loading evaluator uses Sewage Flow = (Volume of Tank*Organic Loading)/BOD Influent to evaluate the Sewage Flow, The Sewage Flow into Aeration Tank given Organic Loading formula is defined as the calculation of sewage flow into aeration tank when we have prior information of organic loading. Sewage Flow is denoted by Q symbol.

How to evaluate Sewage Flow into Aeration Tank given Organic Loading using this online evaluator? To use this online evaluator for Sewage Flow into Aeration Tank given Organic Loading, enter Volume of Tank (V), Organic Loading (VL) & BOD Influent (BODi) and hit the calculate button.

FAQs on Sewage Flow into Aeration Tank given Organic Loading

What is the formula to find Sewage Flow into Aeration Tank given Organic Loading?
The formula of Sewage Flow into Aeration Tank given Organic Loading is expressed as Sewage Flow = (Volume of Tank*Organic Loading)/BOD Influent. Here is an example- 20.01808 = (8.99*0.00123)/0.000553.
How to calculate Sewage Flow into Aeration Tank given Organic Loading?
With Volume of Tank (V), Organic Loading (VL) & BOD Influent (BODi) we can find Sewage Flow into Aeration Tank given Organic Loading using the formula - Sewage Flow = (Volume of Tank*Organic Loading)/BOD Influent.
Can the Sewage Flow into Aeration Tank given Organic Loading be negative?
No, the Sewage Flow into Aeration Tank given Organic Loading, measured in Volume cannot be negative.
Which unit is used to measure Sewage Flow into Aeration Tank given Organic Loading?
Sewage Flow into Aeration Tank given Organic Loading is usually measured using the Cubic Meter[m³] for Volume. Cubic Centimeter[m³], Cubic Millimeter[m³], Liter[m³] are the few other units in which Sewage Flow into Aeration Tank given Organic Loading can be measured.
Copied!