Sensible Cooling Load is the heat added or removed from conditioned space by means of roof, ceiling, floor or windows. Check FAQs
Qph=QTLF
Qph - Sensible Cooling Load?QT - Total Cooling Load?LF - Latent Factor?

Sensible Cooling load due to Equipment Example

With values
With units
Only example

Here is how the Sensible Cooling load due to Equipment equation looks like with Values.

Here is how the Sensible Cooling load due to Equipment equation looks like with Units.

Here is how the Sensible Cooling load due to Equipment equation looks like.

11.36Edit=14.2Edit1.25Edit
You are here -
HomeIcon Home » Category Physics » Category Mechanical » Category Refrigeration and Air Conditioning » fx Sensible Cooling load due to Equipment

Sensible Cooling load due to Equipment Solution

Follow our step by step solution on how to calculate Sensible Cooling load due to Equipment?

FIRST Step Consider the formula
Qph=QTLF
Next Step Substitute values of Variables
Qph=14.2Btu/h1.25
Next Step Convert Units
Qph=4.1588W1.25
Next Step Prepare to Evaluate
Qph=4.15881.25
Next Step Evaluate
Qph=3.32705999991934W
LAST Step Convert to Output's Unit
Qph=11.36Btu/h

Sensible Cooling load due to Equipment Formula Elements

Variables
Sensible Cooling Load
Sensible Cooling Load is the heat added or removed from conditioned space by means of roof, ceiling, floor or windows.
Symbol: Qph
Measurement: PowerUnit: Btu/h
Note: Value can be positive or negative.
Total Cooling Load
Total Cooling Load is heat transferred through the building envelope and heat generated by occupants, equipment, and lights.
Symbol: QT
Measurement: PowerUnit: Btu/h
Note: Value can be positive or negative.
Latent Factor
The Latent Factor is approximated latent cooling load.
Symbol: LF
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.

Other Formulas to find Sensible Cooling Load

​Go Sensible Cooling Load due to infiltrating air
Qph=1.1CFMTC

Other formulas in Cooling Loads category

​Go Cooling load for roof, wall or glass given Corrected Cooling Load Temperature Difference
Q=UoArCLTDc
​Go Corrected Cooling Load Temperature Difference given Cooling Load Temperature Difference
CLTDc=CLΔt+LM+(78-tr)+(ta-85)
​Go Average outside temperature on design day
to=tod-(DR2)
​Go Total heat removed from ventilation air
Qt=Qs+Qlv

How to Evaluate Sensible Cooling load due to Equipment?

Sensible Cooling load due to Equipment evaluator uses Sensible Cooling Load = Total Cooling Load/Latent Factor to evaluate the Sensible Cooling Load, Sensible Cooling load due to Equipment formula is defined as the amount of heat generated by equipment in a given space that needs to be removed by the cooling system to maintain a comfortable temperature, taking into account the total heat gain and latent heat factor. Sensible Cooling Load is denoted by Qph symbol.

How to evaluate Sensible Cooling load due to Equipment using this online evaluator? To use this online evaluator for Sensible Cooling load due to Equipment, enter Total Cooling Load (QT) & Latent Factor (LF) and hit the calculate button.

FAQs on Sensible Cooling load due to Equipment

What is the formula to find Sensible Cooling load due to Equipment?
The formula of Sensible Cooling load due to Equipment is expressed as Sensible Cooling Load = Total Cooling Load/Latent Factor. Here is an example- 38.78788 = 4.15882499989918/1.25.
How to calculate Sensible Cooling load due to Equipment?
With Total Cooling Load (QT) & Latent Factor (LF) we can find Sensible Cooling load due to Equipment using the formula - Sensible Cooling Load = Total Cooling Load/Latent Factor.
What are the other ways to Calculate Sensible Cooling Load?
Here are the different ways to Calculate Sensible Cooling Load-
  • Sensible Cooling Load=1.1*Air Infiltration Rate into Room*Temperature Change Between Outdoor and Inside AirOpenImg
Can the Sensible Cooling load due to Equipment be negative?
Yes, the Sensible Cooling load due to Equipment, measured in Power can be negative.
Which unit is used to measure Sensible Cooling load due to Equipment?
Sensible Cooling load due to Equipment is usually measured using the Btu (th) per Hour[Btu/h] for Power. Watt[Btu/h], Kilowatt[Btu/h], Milliwatt[Btu/h] are the few other units in which Sensible Cooling load due to Equipment can be measured.