Fx Copy
LaTeX Copy
Sending End Voltage in T is the voltage at the sending end of a transmission line. Check FAQs
Vs(t)=Vc(t)+(Is(t)Zt2)
Vs(t) - Sending End Voltage in T?Vc(t) - Capacitive Voltage in T?Is(t) - Sending End Current in T?Zt - Impedance in T?

Sending End Voltage using Capacitive Voltage in Nominal T Method Example

With values
With units
Only example

Here is how the Sending End Voltage using Capacitive Voltage in Nominal T Method equation looks like with Values.

Here is how the Sending End Voltage using Capacitive Voltage in Nominal T Method equation looks like with Units.

Here is how the Sending End Voltage using Capacitive Voltage in Nominal T Method equation looks like.

460.467Edit=387Edit+(16.2Edit9.07Edit2)
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Sending End Voltage using Capacitive Voltage in Nominal T Method

Sending End Voltage using Capacitive Voltage in Nominal T Method Solution

Follow our step by step solution on how to calculate Sending End Voltage using Capacitive Voltage in Nominal T Method?

FIRST Step Consider the formula
Vs(t)=Vc(t)+(Is(t)Zt2)
Next Step Substitute values of Variables
Vs(t)=387V+(16.2A9.07Ω2)
Next Step Prepare to Evaluate
Vs(t)=387+(16.29.072)
LAST Step Evaluate
Vs(t)=460.467V

Sending End Voltage using Capacitive Voltage in Nominal T Method Formula Elements

Variables
Sending End Voltage in T
Sending End Voltage in T is the voltage at the sending end of a transmission line.
Symbol: Vs(t)
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
Capacitive Voltage in T
Capacitive Voltage in T is defined as the voltage of the capacitor in a transmission line.
Symbol: Vc(t)
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Sending End Current in T
Sending End Current in T is defined as the amount of current injected into a medium transmission line from the source or injectors.
Symbol: Is(t)
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.
Impedance in T
Impedance in T is defined as the amount of opposition faced by the direct or alternating current when it passes through a conductor component, circuit.
Symbol: Zt
Measurement: Electric ResistanceUnit: Ω
Note: Value should be greater than 0.

Other Formulas to find Sending End Voltage in T

​Go Sending End Voltage using Voltage Regulation in Nominal T Method
Vs(t)=Vr(t)(%Vt+1)

Other formulas in Nominal T Method in Medium Line category

​Go Losses in Nominal T Method
Ploss(t)=3(Rt2)(Ir(t)2+Is(t)2)
​Go Receiving End Angle using Sending End Power in Nominal T Method
Φr(t)=acos(Ps(t)-Ploss(t)Vr(t)Ir(t)3)
​Go Sending End Current using Losses in Nominal T Method
Is(t)=(Ploss(t)32Rt)-(Ir(t)2)
​Go Capacitive Voltage in Nominal T Method
Vc(t)=Vr(t)+(Ir(t)Zt2)

How to Evaluate Sending End Voltage using Capacitive Voltage in Nominal T Method?

Sending End Voltage using Capacitive Voltage in Nominal T Method evaluator uses Sending End Voltage in T = Capacitive Voltage in T+((Sending End Current in T*Impedance in T)/2) to evaluate the Sending End Voltage in T, The Sending End Voltage using Capacitive Voltage in Nominal T method formula is defined as the voltage at the sending end of the medium transmission lines. Sending End Voltage in T is denoted by Vs(t) symbol.

How to evaluate Sending End Voltage using Capacitive Voltage in Nominal T Method using this online evaluator? To use this online evaluator for Sending End Voltage using Capacitive Voltage in Nominal T Method, enter Capacitive Voltage in T (Vc(t)), Sending End Current in T (Is(t)) & Impedance in T (Zt) and hit the calculate button.

FAQs on Sending End Voltage using Capacitive Voltage in Nominal T Method

What is the formula to find Sending End Voltage using Capacitive Voltage in Nominal T Method?
The formula of Sending End Voltage using Capacitive Voltage in Nominal T Method is expressed as Sending End Voltage in T = Capacitive Voltage in T+((Sending End Current in T*Impedance in T)/2). Here is an example- 461.52 = 387+((16.2*9.07)/2).
How to calculate Sending End Voltage using Capacitive Voltage in Nominal T Method?
With Capacitive Voltage in T (Vc(t)), Sending End Current in T (Is(t)) & Impedance in T (Zt) we can find Sending End Voltage using Capacitive Voltage in Nominal T Method using the formula - Sending End Voltage in T = Capacitive Voltage in T+((Sending End Current in T*Impedance in T)/2).
What are the other ways to Calculate Sending End Voltage in T?
Here are the different ways to Calculate Sending End Voltage in T-
  • Sending End Voltage in T=Receiving End Voltage in T*(Voltage Regulation in T+1)OpenImg
Can the Sending End Voltage using Capacitive Voltage in Nominal T Method be negative?
No, the Sending End Voltage using Capacitive Voltage in Nominal T Method, measured in Electric Potential cannot be negative.
Which unit is used to measure Sending End Voltage using Capacitive Voltage in Nominal T Method?
Sending End Voltage using Capacitive Voltage in Nominal T Method is usually measured using the Volt[V] for Electric Potential. Millivolt[V], Microvolt[V], Nanovolt[V] are the few other units in which Sending End Voltage using Capacitive Voltage in Nominal T Method can be measured.
Copied!