Fx Copy
LaTeX Copy
Sending End Current in ECM is defined as the amount of current injected into a medium transmission line from the source or injectors. Check FAQs
Is(ecm)=Vs(ecm)-Vr(ecm)Zecm
Is(ecm) - Sending End Current in ECM?Vs(ecm) - Sending End Voltage in ECM?Vr(ecm) - Receiving End Voltage in ECM?Zecm - Impedance in ECM?

Sending End Current using Impedance in End Condenser Method Example

With values
With units
Only example

Here is how the Sending End Current using Impedance in End Condenser Method equation looks like with Values.

Here is how the Sending End Current using Impedance in End Condenser Method equation looks like with Units.

Here is how the Sending End Current using Impedance in End Condenser Method equation looks like.

16Edit=400Edit-256Edit9Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Sending End Current using Impedance in End Condenser Method

Sending End Current using Impedance in End Condenser Method Solution

Follow our step by step solution on how to calculate Sending End Current using Impedance in End Condenser Method?

FIRST Step Consider the formula
Is(ecm)=Vs(ecm)-Vr(ecm)Zecm
Next Step Substitute values of Variables
Is(ecm)=400V-256V9Ω
Next Step Prepare to Evaluate
Is(ecm)=400-2569
LAST Step Evaluate
Is(ecm)=16A

Sending End Current using Impedance in End Condenser Method Formula Elements

Variables
Sending End Current in ECM
Sending End Current in ECM is defined as the amount of current injected into a medium transmission line from the source or injectors.
Symbol: Is(ecm)
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.
Sending End Voltage in ECM
Sending End Voltage in ECM is the voltage at the sending end of a transmission line.
Symbol: Vs(ecm)
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
Receiving End Voltage in ECM
Receiving End Voltage in ECM is the voltage developed at the receiving end of a transmission line.
Symbol: Vr(ecm)
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Impedance in ECM
Impedance in ECM is defined as the amount of opposition faced by the direct or alternating current when it passes through a conductor component, circuit.
Symbol: Zecm
Measurement: Electric ResistanceUnit: Ω
Note: Value should be greater than 0.

Other Formulas to find Sending End Current in ECM

​Go Sending End Current in End Condenser Method
Is(ecm)=Ir(ecm)+Ic(ecm)
​Go Sending End Current using Losses in End Condenser Method
Is(ecm)=Ploss(ecm)3Recm

Other formulas in End Condenser Method in Medium Line category

​Go Receiving End Current in End Condenser Method
Ir(ecm)=Is(ecm)-Ic(ecm)
​Go Capacitive Current in End Condenser Method
Ic(ecm)=Is(ecm)-Ir(ecm)
​Go Sending End Voltage in End Condenser Method
Vs(ecm)=Vr(ecm)+(Is(ecm)Zecm)
​Go Receiving End Voltage in End Condenser Method
Vr(ecm)=Vs(ecm)-(Is(ecm)Zecm)

How to Evaluate Sending End Current using Impedance in End Condenser Method?

Sending End Current using Impedance in End Condenser Method evaluator uses Sending End Current in ECM = (Sending End Voltage in ECM-Receiving End Voltage in ECM)/Impedance in ECM to evaluate the Sending End Current in ECM, The Sending End Current using Impedance in End Condenser Method formula is defined as the current at the sending end of the medium transmission lines. Sending End Current in ECM is denoted by Is(ecm) symbol.

How to evaluate Sending End Current using Impedance in End Condenser Method using this online evaluator? To use this online evaluator for Sending End Current using Impedance in End Condenser Method, enter Sending End Voltage in ECM (Vs(ecm)), Receiving End Voltage in ECM (Vr(ecm)) & Impedance in ECM (Zecm) and hit the calculate button.

FAQs on Sending End Current using Impedance in End Condenser Method

What is the formula to find Sending End Current using Impedance in End Condenser Method?
The formula of Sending End Current using Impedance in End Condenser Method is expressed as Sending End Current in ECM = (Sending End Voltage in ECM-Receiving End Voltage in ECM)/Impedance in ECM. Here is an example- 8.888889 = (400-256)/9.
How to calculate Sending End Current using Impedance in End Condenser Method?
With Sending End Voltage in ECM (Vs(ecm)), Receiving End Voltage in ECM (Vr(ecm)) & Impedance in ECM (Zecm) we can find Sending End Current using Impedance in End Condenser Method using the formula - Sending End Current in ECM = (Sending End Voltage in ECM-Receiving End Voltage in ECM)/Impedance in ECM.
What are the other ways to Calculate Sending End Current in ECM?
Here are the different ways to Calculate Sending End Current in ECM-
  • Sending End Current in ECM=Receiving End Current in ECM+Capacitive Current in ECMOpenImg
  • Sending End Current in ECM=sqrt(Power Loss in ECM/(3*Resistance in ECM))OpenImg
Can the Sending End Current using Impedance in End Condenser Method be negative?
Yes, the Sending End Current using Impedance in End Condenser Method, measured in Electric Current can be negative.
Which unit is used to measure Sending End Current using Impedance in End Condenser Method?
Sending End Current using Impedance in End Condenser Method is usually measured using the Ampere[A] for Electric Current. Milliampere[A], Microampere[A], Centiampere[A] are the few other units in which Sending End Current using Impedance in End Condenser Method can be measured.
Copied!