Velocity in a Partially Running Sewer is the speed of flow when the sewer isn't fully filled, influenced by depth and slope. Check FAQs
Vs=V(Nnp)(R)16
Vs - Velocity in a Partially Running Sewer?V - Velocity While Running Full?N - Roughness Coefficient for Running Full?np - Roughness Coefficient Partially Full?R - Hydraulic Mean Depth Ratio?

Self Cleansing Velocity given Hydraulic Mean Depth Ratio Example

With values
With units
Only example

Here is how the Self Cleansing Velocity given Hydraulic Mean Depth Ratio equation looks like with Values.

Here is how the Self Cleansing Velocity given Hydraulic Mean Depth Ratio equation looks like with Units.

Here is how the Self Cleansing Velocity given Hydraulic Mean Depth Ratio equation looks like.

4.5508Edit=6.01Edit(0.74Edit0.9Edit)(0.61Edit)16
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Self Cleansing Velocity given Hydraulic Mean Depth Ratio

Self Cleansing Velocity given Hydraulic Mean Depth Ratio Solution

Follow our step by step solution on how to calculate Self Cleansing Velocity given Hydraulic Mean Depth Ratio?

FIRST Step Consider the formula
Vs=V(Nnp)(R)16
Next Step Substitute values of Variables
Vs=6.01m/s(0.740.9)(0.61)16
Next Step Prepare to Evaluate
Vs=6.01(0.740.9)(0.61)16
Next Step Evaluate
Vs=4.55077455852852m/s
LAST Step Rounding Answer
Vs=4.5508m/s

Self Cleansing Velocity given Hydraulic Mean Depth Ratio Formula Elements

Variables
Velocity in a Partially Running Sewer
Velocity in a Partially Running Sewer is the speed of flow when the sewer isn't fully filled, influenced by depth and slope.
Symbol: Vs
Measurement: SpeedUnit: m/s
Note: Value should be greater than 0.
Velocity While Running Full
Velocity while Running Full refers to the speed of fluid flow in a pipe when it's completely filled, influenced by pipe slope and roughness.
Symbol: V
Measurement: SpeedUnit: m/s
Note: Value should be greater than 0.
Roughness Coefficient for Running Full
The Roughness Coefficient for Running Full accounts for uniform surface resistance affecting flow velocity and friction loss.
Symbol: N
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Roughness Coefficient Partially Full
Roughness Coefficient Partially Full means roughness coefficient of pipe while running partially full.
Symbol: np
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Hydraulic Mean Depth Ratio
The Hydraulic Mean Depth Ratio refers to the ratio of the hydraulic mean depth for a partially full pipe to that when it's running full.
Symbol: R
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.

Other Formulas to find Velocity in a Partially Running Sewer

​Go Self Cleansing Velocity using Ratio of Bed Slope
Vs=V((Nnp)(rpfRrf)23S)
​Go Self Cleansing Velocity given Hydraulic Mean Depth for Full Flow
Vs=V(Nnp)(rpfRrf)16
​Go Self Cleansing Velocity given Bed Slope for Partial Flow
Vs=V((Nnp)(rpfRrf)23sss)

Other formulas in Flow Velocity through Circular Sewer category

​Go Velocity Ratio given Ratio of Bed Slope
νsVratio=(Nnp)(rpfRrf)23S
​Go Velocity Ratio given Hydraulic Mean Depth Ratio
νsVratio=((Nnp)(R)16)
​Go Velocity of Full Flow given Hydraulic Mean Depth Ratio
V=Vs(Nnp)(R)16
​Go Velocity of Full Flow given Hydraulic Mean Depth for Full Flow
V=Vs(Nnp)(rpfRrf)16

How to Evaluate Self Cleansing Velocity given Hydraulic Mean Depth Ratio?

Self Cleansing Velocity given Hydraulic Mean Depth Ratio evaluator uses Velocity in a Partially Running Sewer = Velocity While Running Full*(Roughness Coefficient for Running Full/Roughness Coefficient Partially Full)*(Hydraulic Mean Depth Ratio)^(1/6) to evaluate the Velocity in a Partially Running Sewer, Self Cleansing Velocity given Hydraulic Mean Depth Ratio is defined as the minimum speed at which fluid must flow in a sewer to prevent sediment deposition and maintain a clear path. Velocity in a Partially Running Sewer is denoted by Vs symbol.

How to evaluate Self Cleansing Velocity given Hydraulic Mean Depth Ratio using this online evaluator? To use this online evaluator for Self Cleansing Velocity given Hydraulic Mean Depth Ratio, enter Velocity While Running Full (V), Roughness Coefficient for Running Full (N), Roughness Coefficient Partially Full (np) & Hydraulic Mean Depth Ratio (R) and hit the calculate button.

FAQs on Self Cleansing Velocity given Hydraulic Mean Depth Ratio

What is the formula to find Self Cleansing Velocity given Hydraulic Mean Depth Ratio?
The formula of Self Cleansing Velocity given Hydraulic Mean Depth Ratio is expressed as Velocity in a Partially Running Sewer = Velocity While Running Full*(Roughness Coefficient for Running Full/Roughness Coefficient Partially Full)*(Hydraulic Mean Depth Ratio)^(1/6). Here is an example- 4.550775 = 6.01*(0.74/0.9)*(0.61)^(1/6).
How to calculate Self Cleansing Velocity given Hydraulic Mean Depth Ratio?
With Velocity While Running Full (V), Roughness Coefficient for Running Full (N), Roughness Coefficient Partially Full (np) & Hydraulic Mean Depth Ratio (R) we can find Self Cleansing Velocity given Hydraulic Mean Depth Ratio using the formula - Velocity in a Partially Running Sewer = Velocity While Running Full*(Roughness Coefficient for Running Full/Roughness Coefficient Partially Full)*(Hydraulic Mean Depth Ratio)^(1/6).
What are the other ways to Calculate Velocity in a Partially Running Sewer?
Here are the different ways to Calculate Velocity in a Partially Running Sewer-
  • Velocity in a Partially Running Sewer=Velocity While Running Full*((Roughness Coefficient for Running Full/Roughness Coefficient Partially Full)*(Hydraulic Mean Depth for Partially Full/Hydraulic Mean Depth while Running Full)^(2/3)*sqrt(Bed Slope Ratio))OpenImg
  • Velocity in a Partially Running Sewer=Velocity While Running Full*(Roughness Coefficient for Running Full/Roughness Coefficient Partially Full)*(Hydraulic Mean Depth for Partially Full/Hydraulic Mean Depth while Running Full)^(1/6)OpenImg
  • Velocity in a Partially Running Sewer=Velocity While Running Full*((Roughness Coefficient for Running Full/Roughness Coefficient Partially Full)*(Hydraulic Mean Depth for Partially Full/Hydraulic Mean Depth while Running Full)^(2/3)*sqrt(Bed Slope of Partial Flow/Bed Slope of Channel))OpenImg
Can the Self Cleansing Velocity given Hydraulic Mean Depth Ratio be negative?
No, the Self Cleansing Velocity given Hydraulic Mean Depth Ratio, measured in Speed cannot be negative.
Which unit is used to measure Self Cleansing Velocity given Hydraulic Mean Depth Ratio?
Self Cleansing Velocity given Hydraulic Mean Depth Ratio is usually measured using the Meter per Second[m/s] for Speed. Meter per Minute[m/s], Meter per Hour[m/s], Kilometer per Hour[m/s] are the few other units in which Self Cleansing Velocity given Hydraulic Mean Depth Ratio can be measured.
Copied!