Secondary Winding Resistance Formula

Fx Copy
LaTeX Copy
Resistance of Secondary Winding is the resistance of secondary winding. Check FAQs
R2=R'2K2
R2 - Resistance of Secondary?R'2 - Resistance of Secondary in Primary?K - Transformation Ratio?

Secondary Winding Resistance Example

With values
With units
Only example

Here is how the Secondary Winding Resistance equation looks like with Values.

Here is how the Secondary Winding Resistance equation looks like with Units.

Here is how the Secondary Winding Resistance equation looks like.

25.9056Edit=17.99Edit1.2Edit2
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Machine » fx Secondary Winding Resistance

Secondary Winding Resistance Solution

Follow our step by step solution on how to calculate Secondary Winding Resistance?

FIRST Step Consider the formula
R2=R'2K2
Next Step Substitute values of Variables
R2=17.99Ω1.22
Next Step Prepare to Evaluate
R2=17.991.22
LAST Step Evaluate
R2=25.9056Ω

Secondary Winding Resistance Formula Elements

Variables
Resistance of Secondary
Resistance of Secondary Winding is the resistance of secondary winding.
Symbol: R2
Measurement: Electric ResistanceUnit: Ω
Note: Value can be positive or negative.
Resistance of Secondary in Primary
Resistance of Secondary in Primary is the Resistance of Secondary winding in the primary.
Symbol: R'2
Measurement: Electric ResistanceUnit: Ω
Note: Value can be positive or negative.
Transformation Ratio
The Transformation Ratio of the transformer is used to find the relation between primary voltage and secondary voltage.
Symbol: K
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.

Other formulas in Resistance category

​Go Equivalent Reactance of Transformer from Primary Side
X01=XL1+X'2
​Go Equivalent Reactance of Transformer from Secondary Side
X02=XL2+X'1
​Go Primary Leakage Reactance
XL1=X'1K2
​Go Reactance of Primary Winding in Secondary
X'1=XL1K2

How to Evaluate Secondary Winding Resistance?

Secondary Winding Resistance evaluator uses Resistance of Secondary = Resistance of Secondary in Primary*Transformation Ratio^2 to evaluate the Resistance of Secondary, The Secondary Winding Resistance formula is defined as the resistance offered to the flow of current in secondary winding of a transformer. Resistance of Secondary is denoted by R2 symbol.

How to evaluate Secondary Winding Resistance using this online evaluator? To use this online evaluator for Secondary Winding Resistance, enter Resistance of Secondary in Primary (R'2) & Transformation Ratio (K) and hit the calculate button.

FAQs on Secondary Winding Resistance

What is the formula to find Secondary Winding Resistance?
The formula of Secondary Winding Resistance is expressed as Resistance of Secondary = Resistance of Secondary in Primary*Transformation Ratio^2. Here is an example- 25.9056 = 17.99*1.2^2.
How to calculate Secondary Winding Resistance?
With Resistance of Secondary in Primary (R'2) & Transformation Ratio (K) we can find Secondary Winding Resistance using the formula - Resistance of Secondary = Resistance of Secondary in Primary*Transformation Ratio^2.
Can the Secondary Winding Resistance be negative?
Yes, the Secondary Winding Resistance, measured in Electric Resistance can be negative.
Which unit is used to measure Secondary Winding Resistance?
Secondary Winding Resistance is usually measured using the Ohm[Ω] for Electric Resistance. Megohm[Ω], Microhm[Ω], Volt per Ampere[Ω] are the few other units in which Secondary Winding Resistance can be measured.