Secondary leakage reactance of a transformer arises from the fact that all the flux produced by one winding does not link with the other winding. Check FAQs
XL2=X02-XL1K2
XL2 - Secondary Leakage Reactance?X02 - Equivalent Reactance from Secondary?XL1 - Primary Leakage Reactance?K - Transformation Ratio?

Secondary Leakage Reactance given Equivalent Reactance from Secondary Side Example

With values
With units
Only example

Here is how the Secondary Leakage Reactance given Equivalent Reactance from Secondary Side equation looks like with Values.

Here is how the Secondary Leakage Reactance given Equivalent Reactance from Secondary Side equation looks like with Units.

Here is how the Secondary Leakage Reactance given Equivalent Reactance from Secondary Side equation looks like.

0.9628Edit=2.23Edit-0.88Edit1.2Edit2
You are here -

Secondary Leakage Reactance given Equivalent Reactance from Secondary Side Solution

Follow our step by step solution on how to calculate Secondary Leakage Reactance given Equivalent Reactance from Secondary Side?

FIRST Step Consider the formula
XL2=X02-XL1K2
Next Step Substitute values of Variables
XL2=2.23Ω-0.88Ω1.22
Next Step Prepare to Evaluate
XL2=2.23-0.881.22
LAST Step Evaluate
XL2=0.9628Ω

Secondary Leakage Reactance given Equivalent Reactance from Secondary Side Formula Elements

Variables
Secondary Leakage Reactance
Secondary leakage reactance of a transformer arises from the fact that all the flux produced by one winding does not link with the other winding.
Symbol: XL2
Measurement: Electric ResistanceUnit: Ω
Note: Value can be positive or negative.
Equivalent Reactance from Secondary
The Equivalent Reactance from Secondary side is the total Reactance of the Secondary side.
Symbol: X02
Measurement: Electric ResistanceUnit: Ω
Note: Value should be greater than 0.
Primary Leakage Reactance
Primary leakage reactance of a transformer arises from the fact that all the flux produced by one winding does not link with the other winding.
Symbol: XL1
Measurement: Electric ResistanceUnit: Ω
Note: Value can be positive or negative.
Transformation Ratio
The Transformation Ratio of the transformer is used to find the relation between primary voltage and secondary voltage.
Symbol: K
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.

Other Formulas to find Secondary Leakage Reactance

​Go Secondary Leakage Reactance given Impedance of Secondary Winding
XL2=Z22-R22
​Go Secondary Leakage Reactance
XL2=Eself(2)I2

Other formulas in Reactance category

​Go Reactance of Primary in Secondary using Equivalent Reactance from Secondary Side
X'1=X02-XL2
​Go Reactance of Secondary in Primary using Equivalent Reactance from Primary Side
X'2=X01-XL1
​Go Primary Leakage Reactance using Equivalent Reactance from Primary Side
XL1=X01-X'2
​Go Primary Leakage Reactance given Equivalent Reactance from Secondary Side
XL1=X02-XL2K2

How to Evaluate Secondary Leakage Reactance given Equivalent Reactance from Secondary Side?

Secondary Leakage Reactance given Equivalent Reactance from Secondary Side evaluator uses Secondary Leakage Reactance = Equivalent Reactance from Secondary-Primary Leakage Reactance*Transformation Ratio^2 to evaluate the Secondary Leakage Reactance, The Secondary Leakage Reactance given Equivalent Reactance from Secondary Side formula is defined as the reactance that is in the secondary winding. Secondary Leakage Reactance is denoted by XL2 symbol.

How to evaluate Secondary Leakage Reactance given Equivalent Reactance from Secondary Side using this online evaluator? To use this online evaluator for Secondary Leakage Reactance given Equivalent Reactance from Secondary Side, enter Equivalent Reactance from Secondary (X02), Primary Leakage Reactance (XL1) & Transformation Ratio (K) and hit the calculate button.

FAQs on Secondary Leakage Reactance given Equivalent Reactance from Secondary Side

What is the formula to find Secondary Leakage Reactance given Equivalent Reactance from Secondary Side?
The formula of Secondary Leakage Reactance given Equivalent Reactance from Secondary Side is expressed as Secondary Leakage Reactance = Equivalent Reactance from Secondary-Primary Leakage Reactance*Transformation Ratio^2. Here is an example- 0.9628 = 2.23-0.88*1.2^2.
How to calculate Secondary Leakage Reactance given Equivalent Reactance from Secondary Side?
With Equivalent Reactance from Secondary (X02), Primary Leakage Reactance (XL1) & Transformation Ratio (K) we can find Secondary Leakage Reactance given Equivalent Reactance from Secondary Side using the formula - Secondary Leakage Reactance = Equivalent Reactance from Secondary-Primary Leakage Reactance*Transformation Ratio^2.
What are the other ways to Calculate Secondary Leakage Reactance?
Here are the different ways to Calculate Secondary Leakage Reactance-
  • Secondary Leakage Reactance=sqrt(Impedance of Secondary^2-Resistance of Secondary^2)OpenImg
  • Secondary Leakage Reactance=Self Induced EMF in Secondary/Secondary CurrentOpenImg
Can the Secondary Leakage Reactance given Equivalent Reactance from Secondary Side be negative?
Yes, the Secondary Leakage Reactance given Equivalent Reactance from Secondary Side, measured in Electric Resistance can be negative.
Which unit is used to measure Secondary Leakage Reactance given Equivalent Reactance from Secondary Side?
Secondary Leakage Reactance given Equivalent Reactance from Secondary Side is usually measured using the Ohm[Ω] for Electric Resistance. Megohm[Ω], Microhm[Ω], Volt per Ampere[Ω] are the few other units in which Secondary Leakage Reactance given Equivalent Reactance from Secondary Side can be measured.