The Reactance of Secondary in Primary is the reactance of secondary winding in primary. Check FAQs
X'2=(X01-XL1)K2
X'2 - Reactance of Secondary in Primary?X01 - Equivalent Reactance from Primary?XL1 - Primary Leakage Reactance?K - Transformation Ratio?

Secondary Leakage Reactance given Equivalent Reactance from Primary Side Example

With values
With units
Only example

Here is how the Secondary Leakage Reactance given Equivalent Reactance from Primary Side equation looks like with Values.

Here is how the Secondary Leakage Reactance given Equivalent Reactance from Primary Side equation looks like with Units.

Here is how the Secondary Leakage Reactance given Equivalent Reactance from Primary Side equation looks like.

0.9504Edit=(1.54Edit-0.88Edit)1.2Edit2
You are here -

Secondary Leakage Reactance given Equivalent Reactance from Primary Side Solution

Follow our step by step solution on how to calculate Secondary Leakage Reactance given Equivalent Reactance from Primary Side?

FIRST Step Consider the formula
X'2=(X01-XL1)K2
Next Step Substitute values of Variables
X'2=(1.54Ω-0.88Ω)1.22
Next Step Prepare to Evaluate
X'2=(1.54-0.88)1.22
LAST Step Evaluate
X'2=0.9504Ω

Secondary Leakage Reactance given Equivalent Reactance from Primary Side Formula Elements

Variables
Reactance of Secondary in Primary
The Reactance of Secondary in Primary is the reactance of secondary winding in primary.
Symbol: X'2
Measurement: Electric ResistanceUnit: Ω
Note: Value can be positive or negative.
Equivalent Reactance from Primary
The Equivalent Reactance from Primary side is the total Reactance of the primary side.
Symbol: X01
Measurement: Electric ResistanceUnit: Ω
Note: Value should be greater than 0.
Primary Leakage Reactance
Primary leakage reactance of a transformer arises from the fact that all the flux produced by one winding does not link with the other winding.
Symbol: XL1
Measurement: Electric ResistanceUnit: Ω
Note: Value can be positive or negative.
Transformation Ratio
The Transformation Ratio of the transformer is used to find the relation between primary voltage and secondary voltage.
Symbol: K
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.

Other Formulas to find Reactance of Secondary in Primary

​Go Reactance of Secondary in Primary using Equivalent Reactance from Primary Side
X'2=X01-XL1
​Go Reactance of Secondary Winding in Primary
X'2=XL2K2

Other formulas in Reactance category

​Go Reactance of Primary in Secondary using Equivalent Reactance from Secondary Side
X'1=X02-XL2
​Go Secondary Leakage Reactance given Equivalent Reactance from Secondary Side
XL2=X02-XL1K2
​Go Primary Leakage Reactance using Equivalent Reactance from Primary Side
XL1=X01-X'2
​Go Primary Leakage Reactance given Equivalent Reactance from Secondary Side
XL1=X02-XL2K2

How to Evaluate Secondary Leakage Reactance given Equivalent Reactance from Primary Side?

Secondary Leakage Reactance given Equivalent Reactance from Primary Side evaluator uses Reactance of Secondary in Primary = (Equivalent Reactance from Primary-Primary Leakage Reactance)*Transformation Ratio^2 to evaluate the Reactance of Secondary in Primary, Secondary Leakage Reactance given Equivalent Reactance from Primary Side formula is defined as the reactance that is in the secondary winding of the transformer. Reactance of Secondary in Primary is denoted by X'2 symbol.

How to evaluate Secondary Leakage Reactance given Equivalent Reactance from Primary Side using this online evaluator? To use this online evaluator for Secondary Leakage Reactance given Equivalent Reactance from Primary Side, enter Equivalent Reactance from Primary (X01), Primary Leakage Reactance (XL1) & Transformation Ratio (K) and hit the calculate button.

FAQs on Secondary Leakage Reactance given Equivalent Reactance from Primary Side

What is the formula to find Secondary Leakage Reactance given Equivalent Reactance from Primary Side?
The formula of Secondary Leakage Reactance given Equivalent Reactance from Primary Side is expressed as Reactance of Secondary in Primary = (Equivalent Reactance from Primary-Primary Leakage Reactance)*Transformation Ratio^2. Here is an example- 0.9504 = (1.54-0.88)*1.2^2.
How to calculate Secondary Leakage Reactance given Equivalent Reactance from Primary Side?
With Equivalent Reactance from Primary (X01), Primary Leakage Reactance (XL1) & Transformation Ratio (K) we can find Secondary Leakage Reactance given Equivalent Reactance from Primary Side using the formula - Reactance of Secondary in Primary = (Equivalent Reactance from Primary-Primary Leakage Reactance)*Transformation Ratio^2.
What are the other ways to Calculate Reactance of Secondary in Primary?
Here are the different ways to Calculate Reactance of Secondary in Primary-
  • Reactance of Secondary in Primary=Equivalent Reactance from Primary-Primary Leakage ReactanceOpenImg
  • Reactance of Secondary in Primary=Secondary Leakage Reactance/(Transformation Ratio^2)OpenImg
Can the Secondary Leakage Reactance given Equivalent Reactance from Primary Side be negative?
Yes, the Secondary Leakage Reactance given Equivalent Reactance from Primary Side, measured in Electric Resistance can be negative.
Which unit is used to measure Secondary Leakage Reactance given Equivalent Reactance from Primary Side?
Secondary Leakage Reactance given Equivalent Reactance from Primary Side is usually measured using the Ohm[Ω] for Electric Resistance. Megohm[Ω], Microhm[Ω], Volt per Ampere[Ω] are the few other units in which Secondary Leakage Reactance given Equivalent Reactance from Primary Side can be measured.